WARNING
In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or
disconnect the power plug. Then consult your dealer or authorized service personnel.
As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.
• Unit smells of something burning or emits smoke
• Water leaks from the unit
Following symptoms do not indicate the product malfunction, but they are normal functions or characteristics of this product.
Symptom Cause See page
Doesn’t operate immediately:
• If the indoor unit is stopped and then immediately started again, the compressor will not operate for
about 3 minutes, in order to prevent fuse blowouts.
• Whenever the electrical breaker is turned off then on again the protection circuit will operate for
about 3 minutes, preventing unit operation during that period.
–
Noise is heard: • During the operation or immediately after stopping the air conditioner, refrigerant fl owing sound
may be heard. And it is particularly noticeable for 2–3 minutes after starting operation.
• During the operation, a slight squeaking sound produced by the minute expansion and contraction
of the front panel caused by temperature change may be heard.
–
During heating operation, a sizzling sound produced by the automatic defrosting operation may be
heard.
6
Smell coming from the unit: Absorbed room smell generated from interior textile, furniture, or cigarette smoke into the air condi-
tioner may be emitted.
–
Mist or steam is emitted from
the unit:
In COOL or DRY mode, a thin mist generated by condensation formed with sudden cooling process
may be emitted.
–
During heating operation, the fan built-in the outdoor unit may stops and rising steam generated by
the automatic defrosting operation may be seen.
6
Airfl ow is weak or stops: • Immediately after the heating operation is started, the fan speed stays temporarily very low to warm
up the internal parts of the unit.
• In HEAT mode, the outdoor unit stops and the indoor unit operates at very low fan speed if the
room temperature rises above the set temperature.
–
• During Heating operation, the indoor unit will temporarily stop operation (between 7 and 15
minutes) as the Automatic Defrosting mode operates. During Automatic Defrosting operation, the
OPERATION Indicator Lamp will fl ash.
6
• During Dry mode, the indoor unit will operate at low speed; in order to adjust room humidity, the
indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when
adjusting room humidity.
–
• During SUPER QUIET operation, the fan will operate at very low speed.
–
• In the monitor of AUTO operation, the fan will operate at very low speed.
–
Water is produced from the
outdoor unit:
During heating operation, the outdoor unit may emit water generated by the automatic defrosting
operation.
–
Before you call for or request servicing, troubleshoot a problem by performing following checks:
Symptom Diagnostic See page
Doesn’t operate at all:
Has the circuit breaker been turned off?
Has there been a power failure?
Has a fuse blown out or the circuit breaker been tripped?
–
Is the timer operating?
5
Poor Cooling (or Heating)
performance:
Is the air fi lter dirty?
6
Is the intake grill or outlet port of indoor unit blocked?
–
Is the room temperature adjusted appropriately?
3
Is a window or door left opened?
Is direct or strong sunlight shinning into the room in cooling operation?
Are there other heating apparatus or computers operating, or too many people in the room in cool-
ing operation?
–
Is the fan speed set to “QUIET”?
When the fan speed setting is set to “QUIET”, noise reduction is prioritized and the air-conditioning
performance may become lower. If the volume of provided airfl ow is not agreeable to your prefer-
ence, set the fan speed to “LOW” or higher fan speed.
4
The unit operates differently
from the remote controller’s
setting:
Are the batteries used in the remote controller exhausted?
Are the batteries used in the remote controller loaded properly?
3
Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or diagnostics.
• The OPERATION indicator and TIMER indicator blink while the ECONOMY indicator is blinking fast.
Troubleshooting
9315345615_OM.indb 89315345615_OM.indb 8 11/21/2014 2:59:03 PM11/21/2014 2:59:03 PM