Datasheet
A UY35/40/50Ui
80
AUY35/40/50Ui
AUY35-50Ui
81
AUY35Ui AUY40Ui AUY50Ui
3010 3440 4042
3500 4000 4700
3440 3956 4128
4000 4600 4800
3,02 2,96 2,85
2,92 2,82 2,81
230/1/50 230/1/50 230/1/50
1,16/1,37 1,36/1,63 1,65/1,71
10 10 10
5,10/6,0 6,0/7,1 7,2/7,5
(O.U.) 2x2,5+T (O.U.) 2x2,5+T (O.U.) 2x2,5+T
3x1,5+T 3x1,5+T 3x1,5+T
42 42 44
39 39 41
36 36 37
49 49 50
580 (650) 580 (650) 580 (650)
580 (650) 580 (650) 580 (650)
235 (35)/250 235 (35)/250 235 (35)/250
830 830 830
320 320 320
650 650 650
18+2,2 / 54 18+2,2 / 54 18+2,2 / 54
1/4”-3/8” 1/4”-1/2” 1/4”-1/2”
25/15 25/15 25/15
R410A R410A R410A
10 10 10
0 / +43 0 / +43 0 / +43
-15 / +24 -15 / +24 -15 / +24
Models
AUY35Ui AUY40Ui AUY50Ui
INVERTER HEAT PUMP INVERTER HEAT PUMP INVERTER HEAT PUMP
3NGF8420 3NGF8425 3NGF8430
AUY12L AUY14L AUY18LBAB
AOY12L AOY14L AOY18LMAKL
1.225 1.530 1.647
Code
Logistic reference indoor unit
Logistic reference outdoor unit
Price ref.
Cassette inverter
MODEL
Cooling capacity
kcal/h
W
Heating capacity kcal/h
W
Energy efficiency ratio (E.E.R.) Cooling
Heating
Power supply V/nº/Hz
Power consumption (Cooling/Heating) kW
Starting current A
Running current (Cooling/Heating) A
Electrical wiring
Electrical connection
Noise level indoor unit
High dB (A)
Medium dB (A)
Low dB (A)
Noise level outdoor unit dB (A)
Dimensions indoor unit Width mm
Depth mm
Height mm
Dimensions outdoor unit Width mm
Depth mm
Height mm
Net weight (Indoor U./Outdoor U.) kg
Pipe size Inch.
Piping lenght max. (Total/Height) m
Refrigerant type
Refrigerant charge m
Operating range Cooling ºC
Heating ºC
Minimum height:
they only require a false ceiling of 25 cm for installation. They are
ideal for offices, rooms or shops. The rosette coincides with the stan-
dard measurements of the European panel (650x650 mm).
Condensate pump:
standard pump that allows condensate water to be discharged up to
400 mm.
Long-lasting filters:
can be dismantled for easier cleaning.
External air contribution:
outside fresh air can be introduced by connecting a conduit to the
unit. This is especially useful in public premises that hold a lot of
people.