Datasheet
A UY71/80U/F
87
86
AUY71U/F
AUY71U AUY80U AUY71F AUY80A AUY80F
6020 7225 6063 7310 7225
7000 8400 7050 8500 8400
6708 8170 — — —
7800 9500 — — —
2,64 2,85 2,71 2,38 2,85
3,32 3,42
———
230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
2,65/2,35 2,95/2,78 2,60/- 3,53/- 2,95/-
60 70 60 90 70
11,8/10,5 13,6/13,1 11,5/- 16,9/- 13,8/-
(O.U.) 2x4+T (O.U.) 22x4+T (O.U.) 22x4+T (O.U.) 22x4+T (O.U.) 22x4+T
3x1,5+T 3x1,5+T 3x1,5+T 3x1,5+T 3x1,5+T
44 46 44 46 46
42 44 42 44 44
38 41 39 41 41
53 53 53 54 53
830(940) 830(940) 830(940) 830(940) 830(940)
830(940) 830(940) 830(940) 830(940) 830(940)
246(30)/200 246(30)/200 246(30)/200 245(30)/200 246(30)/200
830 900 830 900 900
320 330 320 350 330
650 830 650 900 830
34+6,5/59 34+6,5/69 34+6,5/58 34+6,5/77 34+6,5/68
3/8”-5/8” 3/8”-5/8” 3/8”-5/8” 3/8”-5/8” 3/8”-5/8”
25/15 30/15 25/15 30/15 30/15
R410A R410A R410A R407C R410A
7,5 7,5 7,5 7,5 7,5
0 / +43 0 / +43 0 / +43 0 / +43 0 / +43
-7/ +24 -7/ +24 - - -
AUY71-80U/F
AUY80U/F AUY80A
(mod. AUY_U)
Models
AUY71U AUY80U AUY71F AUY80A AUY80F
HEAT PUMP HEAT PUMP COOLING ONLY COOLING ONLY COOLING ONLY
3NGF4425 3NGF4445 3NGF4225 3NGF4240 3NGF4245
AUY25UUAR AUY30UUAR AUY25FUAR AUY30ELBW AUY30FUAR
AOY25UNAKL AOY30UNBWL AOYFNAKT AOY30EMBL AOY30FNBWL
1.714 1.886 1.562 1.724 1.724
Code
Logistic reference indoor unit
Logistic reference outdoor unit
Price ref.
Cassette
MODEL
Cooling capacity
kcal/h
W
Heating capacity kcal/h
W
Energy efficiency ratio (E.E.R.) Cooling
Heating
Power supply V/nº/Hz
Power consumption (Cooling/Heating) kW
Starting current A
Running current (Cooling/Heating) A
Electrical wiring
Electrical connection
Noise level indoor unit
High dB (A)
Medium dB (A)
Low dB (A)
Noise level outdoor unit dB (A)
Dimensions indoor unit Width mm
Depth mm
Height mm
Dimensions outdoor unit Width mm
Depth mm
Height mm
Net weight (U.Indoor/U. Outdoor) kg
Pipe size Inch.
Piping lenght max. (Total/Height) m
Refrigerant type
Refrigerant charge m
Operating range Cooling ºC
Heating ºC
Remote control with thermo sensor:
this allows the temperature to be read from the remote control in a
more accurate way.
Reduced height:
the cassette units with a movable rosette can be installed in a false
ceiling with a reduced height of up to 200 mm.
Comfort air-conditioning:
the automatic swing allows conditioned air to be correctly distributed,
providing a uniform temperature throughout the room.
Tec hnical specifications
Remote controller with temperature sensor (thermo sensor).
Automatic swing function.
Standard condensate pump (up to 800 mm of water
level difference).
Cassette cooling-pump
086-087 2/05/06 09:40 Página 86
index