Datasheet
Floor/ceiling
ABY40/50/71U/F
101
100
ABY50/71U/FABY40U/F
ABY40-71U/F
(mod. ABY_U)
ABY40U ABY50U ABY71U ABY40F ABY50F ABY71F
3440 4645 5590 3612 4645 5590
4000 5400 6500 4200 5400 6500
4045 5160 6365
—- —- —-
4700 6000 7400 —- —- —-
2,82 2,84 2,69 3,02 2,81 2,65
3,48 3,24 3,22 —- —- —-
230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
1,42/1,35 1,90/1,85 2,42/2,30 1,39/- 1,92/- 2,45/-
31 39 60 31 39 60
6,3/6,0 8,6/8,3
10,8/10,3 6,3/- 8,5/- 11,0/-
(O.U.) 2x2,5+T (O.U.) 2x2,5+T (O.U.) 2x4+T (O.U.) 2x2,5+T (O.U.) 2x2,5+T (O.U.) 2x4+T
2x2,5+2x1,5+T 2x2,5+3x1,5+T 2x4+3x1,5+T 3x1,5+T 3x1,5+T 3x1,5+T
41 46 48 41 46 48
38 42 44 38 42 44
35 37 40 35 37 40
49 52 53 49 52 53
990 990 990 990 990 990
655/199 655/199 655/199 655/199 655/199 655/199
199/655 199/655 199/655 199/655 199/655 199/655
750 830 830 750 830 830
250 320 320 250 320 320
530 650 650 530 650 650
28/35 28/52 28/59 28/35 28/47 28/58
1/4”-1/2” 1/4”-5/8” 3/8”-5/8” 1/4”-1/2” 1/4”-5/8” 3/8”-5/8”
15/8 20/8 20/8 15/8 20/8 20/8
R410A R410A R410A R410A R410A R410A
7,5 7,5 7,5 7,5 7,5 7,5
0 / +43 0 / +43 0 / +43 +21/ +43 +21/ +43 +21/ +43
-8/ +24 -8/ +24 -8/ +24 - - -
Models
Automatic winter adjustment Automatic summer adjustment
1 hour
30
min.
1 hour 30 min.
Adjusted time
Adjusted time
1°C
1°C
2°C
4ºC
1 hour
1 hour
2°C
3°C
Universal installation.
ABY40U ABY50U ABY71U ABY40F ABY50F ABY71F
HEAT PUMP HEAT PUMP HEAT PUMP COOLING ONLY COOLING ONLY COOLING ONLY
3NGF3195 3NGF3220 3NGF3230 3NGF2995 3NGF3020 3NGF3030
ABY14UBBJ ABY18UBBJ ABY24UBBJ ABY14FBBJ ABY18FBBJ ABY24FBBJ
AOY14USDJL AOY18UNBKL AOY24UNBKL AOY14FSDJ AOY18FNBK AOY24FNBK
867 1.000 1.104 781 914 1.028
Code
Logistic reference indoor unit
Logistic reference outdoor unit
Price ref.
Smart functions NMT (Nice Morning Timer) and Sleep.
MODEL
Cooling capacity
kcal/h
W
Heating capacity kcal/h
W
Energy efficiency ratio (E.E.R.) Cooling
Heating
Power supply V/nº/Hz
Power consumption (Cooling/Heating) kW
Starting current A
Running current (Cooling/Heating) A
Electrical wiring
Electrical connection
Noise level indoor unit
High dB (A)
Medium dB (A)
Low dB (A)
Noise level outdoor unit dB (A)
Dimensions indoor unit Width mm
Depth mm
Height mm
Dimensions outdoor unit Width mm
Depth mm
Height mm
Net weight (Indoor U./Outdoor U.) kg
Pipe size Inch.
Piping lenght max. (Total/Height) m
Refrigerant type
Refrigerant charge m
Operating range Cooling ºC
Heating ºC
NMT function:
the Nice Morning Timer allows the unit is to calculate the start time in
order that the room is conditioned at the time set by the user.
Sleep function:
this adjusts the room temperature to the needs of the human body,
raising the programmed room temperature by up to 4ºC in winter and
by up to 2ºC in summer, providing a considerable energy saving.
Air flow direction:
this makes it possible to select the flow output direction and con-
tribute to a more rapid and uniform distribution.
Tec hnical specifications
Floor/ceiling cooling-heat pump
100-101 2/05/06 09:54 Página 100
index