Remote controls
Remote controls
Wall Mounted Inverter (ASY25/35/40/50Ui)
8 Thermostat and time adjustments
9 Air direction selector
10 SWING
Continuous air fan.
11 COIL DRY
Starts the cleaning function.
12 TIMER
Enables automatic on and off programming.
3 “START/STOP” button:
On/off button.
4 TEST RUN
Test run operation.
5 ACL
Carries out a reset.
6 Time adjust
Time adjustment.
7 “SLEEP” function
Automatic nocturnal disconnection program.
1 MASTER CONTROL
Performance mode selector:
AUTO: Automatic
COOL: Cooling
DRY: Dehumidification
FAN: Ventilation
HEAT: Heating
2 FAN CONTROL
Fan velocity selector:
AUTO
HIGH
MED
LOW
Wall Mounted Inverter (ASY20Ui/ASY71Ui(LC)/80Ui(LC)
8 Thermostat and time adjustments
9 Air direction selector
10 SWING
Continuous air fan.
11 COIL DRY
Starts the cleaning function.
12 TIMER
Enables automatic on and off programming.
3 “START/STOP” button:
On/off button.
4 TEST RUN
Test run operation.
5 RESET
6 CLOCK
Time adjustment.
7 “SLEEP” function
Automatic nocturnal disconnection program.
1 MASTER CONTROL
Performance mode selector:
AUTO: Automatic
COOL: Cooling
DRY: Dehumidification
FAN: Ventilation
HEAT: Heating
2 FAN CONTROL
Fan velocity selector:
AUTO
HIGH
MED
LOW
Wall Mounted (ASY20/25/35U/F/ASY25UA/ASY35UA)
“OFF”: Timer off
“ON”: Timer on
“SET”: Timer programmed
“CANCEL”: Operation motivated by the
thermostat
7 “ACL” button
Carries out a reset.
8 SWING
Continuous air fan.
9 SET
Selection of five positions for the air direction.
10 FAN CONTROL
Fan control selector: AUTO, LOW, MED, HIGH and
SUPER QUIET velocity.
11 Thermostat and time adjustments
Room temperature (raising and lowering) and in
time selection in accordance with the TIMER.
AUTO-STANDARD APPROACH at +/- 2 °C
Temperature Mode Adjustments
Environment Operation Thermostat
Standar
> 30 °C Cooling 27 °C
(27 - 30) °C Cooling 26 °C
(24 - 27) °C Dehumidification 24 °C
(22 - 24) °C Ventilation —-
< 22 °C Heating 23 °C
5 “TEST RUN” button
Test run button.
This button is used when the air-conditioner it
installed and cannot be used in normal condi-
tions.
6 TIMER (MODE CONTROL): Adjustments
Used as the timer per connection or per program:
1 “START/STOP” button
START/STOP button:
2 “SLEEP” function
Automatic nocturnal disconnection depending on
the time of year.
3 COIL DRY
Starts the deodorising cleaning function. (only avai-
lable with the inverter - UI series units)
4 Master control
Function control:
AUTO: Automatic
COOL: Cooling
DRY: Drying
FAN: Ventilation
HEAT: Heating
Remote controls