Datasheet

69
68
ACY71U/F
ACY71-80 U/F
ACY80U/F
A CY71/80U/F
(mod. ACY_U)
ACY71U ACY80U ACY71F ACY80F
6020 7225 6063 7225
7000 8400 7050 8400
6622 8170
—- —-
7700 9500 —- —-
2,64 2,81 2,71 2,81
3,3 3,61 —- —-
230/1/50 230/1/50 230/1/50 230/1/50
2,65/2,33 2,99/2,63 2,60/- 2,99/-
60 70 60 70
11,8/10,5 14/12,4 11,5/- 14/-
(O.U.) 2x4+T (O.U.) 2x4+T (O.U.) 2x4+T (O.U.) 2x4+T
3x1,5+T 3x1,5+T 3x1,5+T 3x1,5+T
670/1440 850/1800 670/1440 850/1800
950/1280 1240/1600 950/1280 1240/1800
150/30 150/30 150/30 150/30
100/30 100/30 100/30 100/30
38 40 38 40
36 38 36 38
34 36 34 36
53 53 53 53
1135 1135 1135 1135
700 700 700 700
270 270 270 270
830 900 830 900
320 330 320 330
650 830 650 830
43/59 43/69 43/58 43/68
3/8”-5/8” 3/8”-5/8” 3/8”-5/8” 3/8”-5/8”
25/15 30/15 25/15 30/15
R410A R410A R410A R410A
7,5 7,5 7,5 7,5
0 / +43 0 / +43 0 / +43 0 / +43
-7 / +24 -7 / +24
Models
ACY71U ACY80U ACY71F ACY80F
HEAT PUMP HEAT PUMP COOLING ONLY COOLING ONLY
3NGF5535 3NGF5545 3NGF5035 3NGF5045
ARY25UUAN ARY30UUAN ARY25FUAN ARY30FUAN
AOY25UNAKL AOY30UNBWL AOY25FNAKL AOY30FNBWL
1.637 1.857 1.555 1.764
Code
Logistic reference indoor unit
Logistic reference outdoor unit
Price ref.
Accessories
(see details on page 204)
SIMPLE WIRED REMOTE EXTERIOR ELECTRICAL PUMP
REMOTE CONTROLLER SENSOR HEATER CONDENSATE
3NGF... 4JAG0027 4JAG0025 4JBO0003
81 70 221 To consult
Code
Price ref.
Duct Type
MODEL
Cooling capacity
kcal/h
W
Heating capacity kcal/h
W
Energy efficiency ratio (E.E.R.) Cooling
Heating
Power supply V/nº/Hz
Power consumption (Cooling/Heating) kW
Starting current A
Running current (Cooling/Heating) A
Electrical wiring
Electrical connection
Air flow processed
(min-max) Normal m
3
/h
Low m
3
/h
Static pressure available (max-min) Normal Pa
Low Pa
Noise level indoor unit High dB (A)
(Free departure) Medium dB (A)
Low dB (A)
Noise level outdoor unit dB (A)
Dimensions indoor unit Width mm
Depth mm
Height mm
Dimensions outdoor unit Width mm
Depth mm
Height mm
Net weight (Indoor U./Outdoor U.) kg
Pipe size Inch.
Piping lenght max. (Total/Height) m
Refrigerant type
Refrigerant charge m
Operating range Cooling ºC
Heating ºC
Control zone function:
a single controller allows up to 16 units to be connected, requiring a
single instruction to operate all of them at the same time.
Easy maintenance:
access to all components is very simple thanks to the division of the
structure into several parts.
Maximum versatility:
the Fujitsu conduit units have several options that allow easy
installation. The air return can be vertical or horizontal and there
are two outlets (one on each side) allowing you to choose the best
option for installation.
Duct Type cooling-heat pump
Example of insertion and suspension from the ceiling
respectively.
Easy maintenance.
Conventional model New model
Lower panel: 1 units
Lower panel: 2 units
1. Control
panel
2. Fan cover
3. Fan
4. Motor
Tec hnical specifications
068-069 2/05/06 09:24 Página 68