OPERATING MANUAL MODE D’EMPLOI MANUAL DE FUNCIONAMIENTO AIR CONDITIONER Español Français English CASSETTE TYPE KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED 9368987046_OM_cover1.
CONTENTS SAFETY PRECAUTIONS ................................................ 1 NAME OF PARTS ........................................................... 2 PREPARATORY OPERATION ......................................... 3 OPERATION ................................................................... 3 TIMER FUNCTIONS ....................................................... 5 ON/OFF TIMER .............................................................. 5 WEEKLY TIMER ..............................................
NAME OF PARTS Remote controller H G F SU MO TU WE TH FR SA I E J D 1 3 6 9 12 15 18 21 2 DAY 7 8 9 0 A B 1 2 3 4 5 6 7 8 9 0 A B CLOCK ADJUST DAY OFF SET BACK DELETE ENERGY SAVE 3 4 5 6 THERMO SENSOR SET C Start/Stop Button Set Temperature Button Master Control Button Fan Control Button THERMO SENSOR Button ENERGY SAVE Button Timer Mode (CLOCK ADJUST) Button DAY (DAY OFF) Button SET BACK Button Set Time Button DELETE Button SET Button C Vertical Airflow Direction and Swing Button D Operati
PREPARATORY OPERATION Set the current day and time 1 2 CLOCK ADJUST Press the timer mode (CLOCK ADJUST) button for 2 seconds or more. The time display on the remote controller will flash. DAY Press the DAY button and select the current day. appears around the selected day. A DAY OFF SU MO TU WE Press the set time buttons to set the current time. Press repeatedly to adjust the current time in 1minute increments. Press and hold to adjust the current time in 10-minute increments.
OPERATION Energy save ENERGY SAVE Press the ENERGY SAVE button to start or stop the energy-saving air conditioner operation. For details on the function, refer to page 9. Room temperature sensor selection THERMO SENSOR Indoor unit Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit (remote sensor) or the remote controller. thermo sensor display appears, the room When the temperature is detected at the remote controller.
TIMER FUNCTIONS OFF timer (See page 5.) Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops after the set time has passed. The timer can be set up to 24 hours in advance. ON timer (See page 5.) Use this timer function to start air conditioner operation. The timer operates and air condition operation starts after the set time has passed. The timer can be set up to 24 hours in advance. WEEKLY timer (See page 6.
WEEKLY TIMER Weekly timer setting 1 2 SU MO TU WE TH FR SA SET CLOCK ADJUST 3 6 9 12 15 18 21 Press the SET button for 2 seconds or more. Press the timer mode button to select the weekly timer. 3 ● Day of the week setting ALL SET DAY DAY OFF SU MO TU WE TH FR SA 2 1 SU MO TU WE TH FR SA Press the DAY button to select the day of the week, and then press the SET button to confirm the setting. For ALL, all of the days can be set together when a appears around each day.
WEEKLY TIMER WEEKLY timer operation ● To start ● To cancel SU MO TU WE TH FR SA DELETE CLOCK ADJUST 3 6 9 12 15 18 21 When the weekly timer is selected, the timer starts automatically. • Press the DELETE button to cancel the timer mode. • The timer mode can also be canceled by changing the timer mode using the timer mode button. 3 6 9 12 15 18 21 ex. Operating time 7:00 A.M. –6:00 P.M. (7:00–18:00) The operating time for the current day is displayed.
TEMPERATURE SET BACK TIMER Temperature SET BACK timer setting SET BACK 1 SU MO TU WE TH FR SA If there is no existing SET BACK temperature setting, “- -” will be displayed for the temperature. 3 6 9 12 15 18 21 Press the SET button for 2 seconds or more. Press the SET BACK button to change to the SET BACK confirmation display. The SET BACK operating time and the set temperature will be displayed.
OPERATING TIPS Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Mode operation: AUTO COOLING MODEL • When the room temperature is 4 °F higher than the set temperature, the mode will switch between Cooling and Drying. • During the Drying mode operation, the FAN setting should be switched to LOW for a gently cooling effect during which the fan may temporarily stop rotating.
OPERATING TIPS Multi-type Air conditioner This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output. Simultaneous Use of Multiple Units Instructions relating to inverter (❖) are applicable only to “INVERTER MODEL”.
ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Start air conditioner operation before performing this procedure. To adjust the vertical airflow direction Press the vertical airflow direction and swing button. vertical swing display flashes each time the vertical airflow The direction and swing button is pressed. Each time the button is pressed, the airflow direction setting changes as shown in the following figure.
CARE AND MAINTENANCE CAUTION! ● Before cleaning the unit, be sure to stop the unit and power supply. (Turn off the electrical breaker) ● A fan operates at high speed inside the unit, and personal injury could result. Cleaning the air filter 1 Push the intake grille pushbuttons (two places) and open the intake grille. OPEN 2 OPEN PUSH PUSH Hold down the hook at A and pull the filter out.
CARE AND MAINTENANCE How to cleaning • When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel. • When cleaning the unit’s body, do not use water hotter than 100 °F, harsh abrasive cleansers, or volatile agents like benzene or thinner. • Do not expose the unit body to liquid insecticides or hairsprays.
TROUBLESHOOTING Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). WARNING! In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker to ensure that power is completely off.
TROUBLESHOOTING Symptom NORMAL FUNCTION Problem See Page Water is produced from the outdoor unit: ● During Heating operation, water may be produced from the outdoor unit due to the Automatic Defrosting operation. 9 thermo sensor display on the remote controller is flashing: ● The room temperature sensor may be malfunctioning. Please consult authorized service personnel.