ASU7RLF1 Installation Manual

En-4
5.4. Installing the wall hook bracket
• Remove the wall hook bracket from the indoor unit. (Remove 2 screws).
(1) Install the wall hook bracket so that it is correctly positioned horizontally and vertically.
If the wall hook bracket is titled, water will drip to the oor.
(2)
Install the wall hook bracket so that it is strong enough to support the weight of the unit.
Fasten the wall hook bracket to the wall with 5 or more screws through the holes near the
outer edge of the bracket.
Check that there is no rattle at the wall hook bracket.
Tapping screws (large, accessories)
Wall hook bracket
CAUTION
Install the wall hook bracket both horizontally and vertically aligned.
Misaligned installation may cause water leakage.
5.5. Forming the drain hose and pipe
[Rear piping, Right piping, Bottom piping]
• Install the indoor unit piping in the direction of the wall hole and bind the drain hose
and pipe together with vinyl tape.
• Install the piping so that the drain hose is at the bottom.
• Wrap the pipes of the indoor unit that are visible from the outside with decorative tape.
[For Left rear piping, Left piping]
Interchange the drain cap and the drain hose.
CAUTION
Insert drain hose and drain cap securely. Drain should slope down to avoid water
leakage.
• When inserting, be sure not to attach any material besides water. If any other
material is attached, it will cause deterioration and water leakage.
After removing the drain hose, be sure not to forget mounting the drain cap.
Be sure to x the drain hose with tape to the bottom of piping.
Prevent drain water freezing under low temperature environment.
When installing indoor unit’s drain hose outdoors, necessary measure for frost
protection should be taken to prevent drain water freezing.
Under low temperature environment [when outdoor temperature under 32 °F
(0 °C)], after cooling operation is executed, water in the drain hose could be frozen.
Once drain water is frozen, the drain hose will be blocked and water leakage may
result at the indoor unit.
Installation method of drain cap
Use a hexagonal wrench 3/16 in. (4 mm) at opposite
side to insert the drain cap, till the drain cap contacts the
tip of drain cock.
Right piping
Bottom piping
Bind with vinyl tape
Refrigerant pipes (top)
Rear piping
Indoor unit drain hose (bottom)
No gap
Hexagonal
wrench
Drain
cock
Drain cap
For left outlet piping,
cut off the piping
outlet cutting groove
with a hacksaw.
Indoor unit
drain hose
Drain cap
Remove the drain cap by pull-
ing at the projection at the end
of the cap with pliers, etc.
Removal method of drain hose
Remove the screw at the left of drain
hose and pull out drain hose.
Installation method of drain hose
Vertically insert the drain hose toward the
inside, so that the drain xture (white) can ac-
curately align with the screw hole around the
drain cock.
After inserting and before replacing, please
reinstall and x the removed screws.
Please hold around the joint of the drain hose during working.
As the screw is inside, be sure to use screwdriver treated with magnet.
Screw
Drain xture
Drain hose
Screw hole
Drain cock
Drain hose
Screw
Drain xture
For left piping and left rear piping, align the marks on the wall hook bracket and shape the
connection pipe.
• Bend the connection piping at a bend radius of 2-3/4 in. (70 mm) or more and install no
more than 1-6/16 in. (35 mm) from the wall.
After passing the indoor piping and drain hose through the wall hole, hang the indoor unit on
the hooks at the top and bottom of the wall hook bracket.
[Installing the indoor unit]
Hang the indoor unit from the hooks at the top of the wall hook bracket.
Insert the spacer, etc. between the indoor unit and the wall hook bracket and separate
the bottom of the indoor unit from the wall.
Indoor unit
Wall hook bracket
(Spacer)
Connection pipe [1/4 (6.35) dia.]
Align the marks
Indoor unit
Connection pipe [3/8 (9.52) or 1/2 (12.70) dia.]
Top hooks
Bottom hooks
Wall hook bracket
Bend R2-3/4
(70) with a pipe
bender
After hooking the indoor unit to the top hook, hook the ttings of the indoor unit to the 2
bottom hooks while lowering the unit and pushing it against the wall.
5.6. Pipe connection
CAUTION
Tighten the are nuts with a torque wrench using the speci ed tightening method.
Otherwise, the are nuts could break after a prolonged period, causing refrigerant to
leak and generate hazardous gas if the refrigerant comes into contact with a ame.
5.6.1. Flaring
Use special pipe cutter and are tool exclusive for R410A.
(1) Cut the connection pipe to the necessary length with a pipe cutter.
(2) Hold the pipe downward so that cuttings will not enter the pipe and remove any burrs.
(3)
Insert the are nut (always use the are nut attached to the indoor unit(s) and outdoor
unit respectively) onto the pipe and perform the are processing with a are tool. Use the
special R410A are tool, or the conventional are tool. Leakage of refrigerant may result if
other are nuts are used.
(4) Protect the pipes by pinching them or with tape to prevent dust, dirt, or water from
entering the pipes.
Unit: in (mm)
9333005102-04_IM.indb 49333005102-04_IM.indb 4 2018/3/16 15:03:082018/3/16 15:03:08