ASU7RLF1 Installation Manual

En-8
10. OPTIONAL KIT INSTALLATION
This air conditioner can be connected with the following optional kits.
Wired remote controller
Simple remote controller
External connect kit
10.1. Before installing wired remote controller
When you use wired remote controller, some functions may not be used.
CAUTION
Before installing, be sure to disconnect all power supply.
Don’t touch the heat exchanger.
During installing or removing operation, be sure not to have wire caught by parts or
draw it hard. Or it may result troubles to the air-conditioner.
Avoid place in direct sunlight.
Select place that will not be affected by the heat from a stove, etc
Before setting up the optional kit, please con rm whether air-conditioner can receive
the signal.
Do not connect the wired remote controller to the terminal for power supply.
When connecting the wired remote controller with the indoor unit, use the connecting
cable (supplied with wired remote controller or simple remote controller).
Recommended cable length of wired remote controller is 32 ft. (10 m). Make sure to
insulate the connecting part when extended the cable.
Do not connect power supply with the terminal.
INDOOR UNIT
PCB
TERMINAL
10.2. Remote controller cable modi cation
(1) Use a tool to cut off the terminal on the end of the remote controller cable, and then
remove the insulation from the cut end of the cable.
(2) Connect the remote controller cable and connecting cable.
(supplied with wired remote controller)
Important: Be sure to insulate the connection between the wires.
Connecting cable
White
Red
White
Red
Black
Black
Insulated
connection
Remote
controller cable
Remote
controller cable
13/16 in.
(20 mm)
10.3. Installing wired remote controller terminal /
external connect kit terminal (sold separately)
(1)
Remove the screw on the control box as shown on the top right of the following figure.
(2) Release both bottom clasps at the sides in the direction of the arrow as circled in
the bottom left of the following figure. Pull and remove the cover.
(2)
(1)
Cover
(3) Connect the wired remote controller terminal / external connect kit terminal (sold
separately) to the specified terminal on the board as shown below. Please connect
to the connector with necessary function according to the actual usage.
(4) After connecting each terminal, thread the cables through the notch as circled on
the bottom right of the following figure.
(3) Control input (Operation/
Stop or Forced stop) con-
nector
: CNA01(White) *
(3) Wired remote controller
connector
: CNC01(White) *
* : Symbol indicating the location printed on the board
(3) Error Status output
connector
: CNB02(Black) *
(3) Operation status
output connector
: CNB01(White) *
(4)
(5) Install the control box cover as shown below.
(Align the cover with the upper and lower right corners as indicated by the triangular
symbols on the figure.
Insert the clasps on the cover into both sides at the bottom of the two dotted
circles.)
When installing the control box cover, make sure that the cables are not caught as
shown in the detail view.
(6) Install one screw.
(7) Screw the earth wire of wired remote controller as shown in the figure.
(AUSTRALIA model only).
(7)
(5)
(5)(6)Cover
Detail view
10.4. Installing communication box
10.4.1. Removing intake grille
( Refer to 8.1. Front panel removal )
10.4.2. Removing control box
(1) Remove the screws (x4). (Use the same screws when installing.)
(2) Pull the control box cover towards you and remove.
(1)
(1)
(2)
(1)
(1)
(3) Remove the connectors (x4).
Remove and pull off the lock at the side of the connector insertion part.
CAUTION
Be careful not to damage the parts on the board.
Otherwise, it will cause malfunction.
Connector number: CN 5
Connector number: CN 4
Connector number: CN 3
Connector number: CN 7
* : Symbol indicating the location printed on the board
9333005102-04_IM.indb 89333005102-04_IM.indb 8 2018/3/16 15:03:112018/3/16 15:03:11