6. INSTALLATION WORK
WARNING
During transportation or relocation of the indoor unit, pipes shall be covered with the
wall hook bracket for protection. Do not move the appliance by holding the indoor unit
pipes.
(The stress applied to the pipe joints may cause the ammable gas to leak during
operation.)
CAUTION
Do not hit or push the human sensor. This may lead to damage or malfunction.
Do not touch the human sensor. Any scratches or dirt may lead to incorrect detection.
Do not place large objects near the
human
sensor. Also keep heating units outside the
sensor’s detection area.
Detection range of the
human
sensor is as follows.
Vertical angle 90° (Side view)
90°
50°50°
6 m
6 m
Horizontal angle 100° (Top view)
6.1. Installation dimensions
Keep the distance between the wall hook bracket or indoor unit to the surrounding walls
as indicated in the following gure.
Wall hook bracket
Outline of the indoor unit
(50 or
more)
67 or
more
(40 or
more)
(70 or
more)
107 or
more
1,500
or more
1,800 or more
Unit: mm
183 or
more
6.2. Indoor unit piping direction
The piping can be connected in the
6
directions indicated in the following.
When the piping is connected to direction (2) , (3) , (4) or (5) ,
cut along the piping groove
on the side of the under cover with a hacksaw.
(2)
Right
outlet
(5) Left
outlet
(6) Left rear
outlet
(3) Bottom outlet
(1) Rear outlet
(4) Left bottom outlet
(Rear)
Piping groove
Under cover
Under cover
(inside view)
To lay the pipe out at the right, bottom, left bottom, or left outlet, remove the piping cut-out.
For right and left piping layout
Prepare the cut-out area with a utility
knife and remove it using a nipper.
For bottom and left bottom piping
layout
Remove the cut-out area using a nipper.
Cut-out
Front panel
Remove
Under cover
Under cover
Remove
(Ex.) For left piping layout
(Ex.) For left bottom piping layout
Cut-out
6.3.
Cutting the hole in the wall for connecting the pipes
(1) Cut a 65 mm diameter hole in the wall at the position shown in the following.
(2) Cut the hole so that the outside end is lower (5 to 10 mm) than the inside end.
(3) Always align the center of the wall hole. If misaligned, water leakage will occur.
(4)
Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap with
vinyl tape, and stick the pipe through the hole.
(5) For left piping and right piping, cut the hole a little lower so that drain water will ow
freely.
Wall hook bracket
Centering marks
65 mm
hole
94 mm
84 mm
65 mm
hole
* Locally purchased
Fasten with vinyl tape *
5~10 mm
Wall pipe *Wall cap *
(Inside)
(Outside)
Wall
WARNING
Always use the wall pipe. If the wall pipe is not used, the cable that is connected between
the indoor unit and the outdoor unit may touch metal, and cause an electric discharge.
6.4. Installing the wall hook bracket
(1) Install the wall hook bracket so that it is correctly positioned horizontally and vertically.
If the wall hook bracket is titled, water will drip to the oor.
(2)
Install the wall hook bracket so that it is strong enough to support the weight of the unit.
• Fasten the wall hook bracket to the wall with 5 or more screws through the holes near
the outer edge of the bracket.
• Check that there is no rattle at the wall hook bracket.
Wall hook bracket
Screws (Large, accessories)
9387603033_IM.indd 3 21/11/2018 15:03:20