Installation guide
En-8
(2) Press and close the intake grille.
Press here
9.2. Front panel / control cover removal and installation
* In this description, the intake grille and wire cover already has been removed.
9.2.1. Front panel / control cover / under cover removal
(1) Remove the under covers. (Press down on the markings on the side, then slide down.)
(2) Remove the screw covers (2 places) on the bottom of the front panel, and then remove
the screws (4 places).
(3) Push down on the markings (2 places) on top of the front panel to release the hooks
(3 places), then pull the front panel towards you.
(4) Pinch the tab on the control cover to release the hook, then open.
Control cover
Screws (4 places)
Hook (3 places)
Markings
(triangle)
Markings (triangle)
Markings (triangle)
Markings (triangle)
Screw covers
Tab
Under covers
9.2.2. Front panel / control cover / under cover installation
Reverse the procedures in “9.2.1. Front panel / control cover / under cover removal”.
* Be sure to replace the screws (4 places) and screw cover (2 places).
CAUTION
Please take caution when removing or installing the front panel. If the front panel falls,
there is a risk of injury.
9.3. Uninstalling the indoor unit
Remove the indoor unit from the wall hook bracket as follows.
(1) Remove the under covers. (See “9.2.1. Front panel / control cover / under cover
removal”.)
(2) Insert your ngers in the opening shown in the gure.
While pushing down on the lower part of the opening, release the hooks (2 places).
(3) Pull the indoor unit towards you.
Markings (triangle)
Hooks (rear side)
10. TEST RUN
Check items
(1) Is operation of each button on the remote controller normal?
(2) Does each lamp light normally?
(3) Do airow direction louvers operate normally?
(4) Is the drain normal?
(5) Do not have an abnormal noise and vibration during operation?
Do not operate the air conditioner in test run for a long time.
[Operation method]
Depending on your installation, choose from the following:
By the wireless remote controller (with [TEST RUN] button)
•
To start test run, press [
] and [TEST RUN] on the remote controller.
•
To end test run, press [
] on the remote controller.
By the indoor unit or IR receiver unit
•
To start test run, press [MANUAL AUTO] of the unit for more than 10 seconds (forced
cooling).
•
To end test run, press [MANUAL AUTO] for more than 3 seconds or press [
] on the
remote controller.
By the wired remote controller
•
For the operation method, refer to the installation manual and the operating manual of
the wired remote controller.
The Operation indicator and Timer indicator will simultaneously ash during the test run
mode.
Heating test run will begin in a few minutes when Heating is selected by the remote
controller [reverse cycle model only].
11. REMOTE CONTROLLER INSTALLATION
Check that the indoor unit correctly receives the signal from the remote controller, then
install the remote controller holder.
CAUTION
Do not install the remote controller holder in the following conditions:
• Any places exposed in direct sunlight
• Positions affected by the heat from a stove or heater
11.1. Remote controller holder installation
• Install the remote controller a maximum distance of 7 m from the remote control signal
receiver. After installing the remote controller, check that it operates correctly.
• I
nstall the remote controller holder to a wall, pillar, etc. with the tapping screw.
Remote controller
holder
Tapping
screw
(small)
(1) Set
Remote
controller
(2) Down
11.2. Remote controller custom setting
When two or more air conditioners are installed in a room and the remote controller is oper-
ating an air conditioner other than the one you wish to set, change the custom code of the
remote controller to operate only the air conditioner you wish to set (4 selections possible).
Remote Controller Custom Code Setting
Use the following steps to select the custom code of the remote controller. (Note that
the air conditioner cannot receive a signal if the air conditioner has not been set for the
matching custom code.)
(1) Press [
] until only the clock is displayed on the
remote controller display.
(2) Press [MODE] for at least 5 seconds to display the cur-
rent custom code (initially set to A).
(3) Press [TEMP.] (
/ ) to change the custom code
between
A↔B↔C↔D
.
Match the code on the display to the air conditioner
custom code.
(4) Press [MODE] again to return to the clock display. The
custom code will be changed.
• If no buttons are pressed within 30 seconds after the custom code is displayed, the
system returns to the original clock display. In this case, start again from step 1.
• The air conditioner custom code is set to A prior to shipment.
• Depending on the remote controller, the custom code may return to A when the
batteries are replaced. In this case, if you use a code other than A, reset the custom
code. If you do not know the air conditioner custom code setting, try each code
(A→B→C→D) until you nd the code which operates the air conditioner.
9387603019_IM_En.indd 8 2/6/2018 10:12:11