OPERATING MANUAL AIR CONDITIONER Wall Mounted Type MODEL: * Please write down the model name. (Refer to the rating label.) R32 REFRIGERANT This Air Conditioner contains and operates with refrigerant R32. THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL. Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation & operation manuals, before the installation, maintenance or service of this product.
Contents CAUTION 1. SAFETY PRECAUTIONS........................................... 1 2. PREPARATION.......................................................... 2 3. NAME OF PARTS...................................................... 3 3.1. Indoor unit......................................................... 3 3.2. Remote controller.............................................. 3 4. BASIC OPERATIONS................................................ 5 5. AIRFLOW SETTINGS..........................................
WARNING • Do not start or stop the operation of this product by inserting or pulling out the power plug, or by turning on or off the circuit breaker. • Do not use flammable gases near this product. • Do not expose yourself directly to the cooling airflow for many hours. • Do not insert your fingers or any other objects into outlet port or inlet port. • Do not operate with wet hands.
3.2. Remote controller 3. NAME OF PARTS CAUTION For appropriate signal transmission between the remote controller and the indoor unit, keep the signal receiver away from the following items: -- Direct sunlight or other strong lights -- Flat-panel television screen In rooms with instantaneous fluorescent lights, such as inverter type ones, the signal may not be transmitted properly. In such a case, consult the store of purchase. 3.1.
CAUTION • To prevent malfunction or damage of the remote controller: -- Place remote controller at where will not be exposed to direct sunlight or excessive heat. -- Remove batteries if the product is not going to be used for an extended period. • Obstacles such as a curtain or wall between the remote controller and the indoor unit may affect the appropriate signal transmission. • Do not apply strong shocks to the remote controller. • Do not pour water on the remote controller. For Powerful operation ....
■■ Airflow direction range 4. BASIC OPERATIONS Vertical airflow direction ■■ 3 steps to start operation 1. Press 2. Press to select the operation mode. The operation mode changes as follows. AUTO COOL 3. Press DRY FAN HEAT to set the desired temperature. The temperature changes by 0.5 °C increments. Temperature setting range Auto/Cooling/Dry 18.0 - 30.0 °C Heating 16.0 - 30.0 °C NOTES: • In the Cooling or Dry mode, set the temperature lower than the current room temperature.
■■ Examples of Weekly timer 6.1. Weekly timer Example 1 ■■ Setting details 1. Select Weekly timer in step 2 of "Timer setting procedure". ( 2. Press day of the week. ) to select the program number and the 7:00 Monday to Friday Selected program number (1~4) and the day of the week will blink. Monday Tuesday Wednesday Thursday Friday Saturday Sunday 3. Press . 4.
7. ENERGY SAVING OPERATIONS Detection range of Human sensor Side view Top view 7.1. Economy operation 6m It saves more electricity than other operation modes by changing the set temperature to a moderate setting. Press )) operation. [ 50° to activate/deactivate the Economy ] indicator on the indoor unit will turn on.
■■ Details on Demand Response mode DR mode Description of operation in this mode DR mode 1 Compressor off. DR mode 2 Electrical energy consumption in 30 minutes: 50 % or less (compared with rated energy consumption) DR mode 3 Electrical energy consumption in 30 minutes: 75 % or less (compared with rated energy consumption) NOTES: • During the DR mode, the cooling or heating performance may be reduced. • During the DR mode, only the following operations are valid.
2. Remove the air filters. 10. CLEANING AND CARE Lift up the air filters' handle, disconnect the two lower tabs, and pull out. Air filter handle CAUTION • Before cleaning this product, be sure to turn it off and disconnect all the power supply. • Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.
9. Install the air cleaning filter holders to the air filters. Engage the 4 hooks at the rear of the air cleaning filter frame with the latch at both ends of the air filter. * Take care that the air cleaning filter does not project beyond the frame. Hook (4 places at the rear) After extended non-use of the unit If you have shut down the indoor unit for 1 month or more, perform the Fan mode operation for half a day to dry the internal parts thoroughly before the normal operation.
■■ Indoor unit temperature and humidity range Permissible ranges of temperature and humidity are as follows: Indoor temperature Cooling/Dry [°C] 18 to 32 Heating [°C] 16 to 30 [%] 80 or less *1) Indoor humidity *1) If the air conditioner is used continuously for many hours, water may condense on the surface and drip. • If the unit is operated under the conditions except the permissible temperature range, the air conditioner operation may stop because of the automatic protection circuit working.
Step 4. Air conditioner registration (pairing of W-LAN adapter) NOTES: • Before starting this setting, reconnect the power supply of the air conditioner and wait for 60 seconds or more. • Check that the smartphone or tablet PC is linked to the wireless router you are connecting the air conditioner. The setting will not work if it is not connected to the same wireless router. • To control 2 or more air conditioners with the same smartphone or tablet PC, repeat the setup of the chosen mode.
13. TROUBLESHOOTING WARNING In the following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel. As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off. • Unit smells of something burning or emits smoke • Water leaks from the unit Does not operate at all.
■■ State of indicator lamps : The instruction is relating to the wireless LAN control (optional). Lighting pattern: Off, State (3 times) On, Blinking, Any state Causes and solutions See page Automatic defrosting operation ⇒ Please wait until finishing the defrosting (maximum of 15 minutes). 10 Filter indicator ⇒ Clean the air filter and reset the filter sign. 10 Demand response operation 7 (Twice) Error code display ⇒ Consult authorized service personnel.
OM_9387602043.