1 = The maximum current is the maximum value when operated within the operation range.
Capacity
Cooling
Rated
kW 9.4
Range
kW 2.9 – 11.2
Heating
Rated
Kw 10.3
Range
kW 2.7 – 11.7
Input
Cooling
kW 2.78
Heating
kW 2.84
Current
Cooling
A 11.7
Heating
A 12.9
Max
Running
Current
Cooling
(1)
A 19.5
Heating
A 20.5
Starting Current
A 12.9
EER (Cooling)
3.38
AEER
3.476
COP (Heating)
3.63
ACOP
3.735
Moisture Removal
l/h
Air Circulation
Indoor (High Fan)
l/s 389
Outdoor
l/s 1139
Power Supply Outdoor
240V - 1Ph - 50Hz
Sound Pressure
Level
Indoor (High Fan)
dB 51
Outdoor
dB 51
Sound Power
Level
Outdoor
dB 65
Weight (Net)
Indoor
Kg 18
Outdoor
Kg 74
Dimensions
HxWxD (mm)
Indoor
340 x 1150 x 280
Outdoor
914 × 970 × 370
Connection Pipe
Sizes
Liquid
mm Ø 9.52
Gas
mm Ø 15.88
Drain Pipe Sizes
Internal
mm
13.8
External
mm
20
Cooling/Heating capacities are based on
the following conditions (AS3823).
Cooling
Indoor temp : 27°C DB / 19°CWB
Outdoor temp : 35°C DB / 24°C WB
Heating
Indoor temp : 20°C DB / 15°C WB
Outdoor temp : 7°C DB / 6°C WB
Running current is at rated conditions
(AS3823) and does not include
compressor start-up or variations in
power supply and load conditions.
All wiring specifications are minimum
recommendations. Please consult
AS/NZS 3000 and your local wiring rules
for clarification of cable and circuit
requirements.
Suitable access for warranty & service is
required.
SOUND POWER LEVELS measured in
accordance to AS1217.
Specifications and design are subject to
change without notice. Please check
with your dealer.