User Manual

En-8
8. OTHER OPERATIONS
8.1. Powerful operation
In the Powerful operation, the air conditioner will operate at maximum
power and strong airow to cool down or warm up the room quickly.
Press to activate/deactivate the Powerful operation.
When activated, the indoor unit will emit 2 short beeps.
When deactivated, the indoor unit will emit 1 short beep.
The Powerful operation will be turned o󰀨 automatically in the following
situations:
The Powerful operation runs for a certain amount of time and the
room temperature reaches the set temperature in the Cooling, Dry,
or Heating mode.
20 minutes after the Powerful operation has started.
NOTES:
The airow direction and the fan speed are controlled automatically.
The Powerful operation cannot be performed simultaneously with
Economy operation.
The Powerful operation overrides the following operations. If
the following operations are set, they will start after the Powerful
operation nishes.
- Outdoor Unit Low Noise operation
- Energy Saving program
If the wired remote controller (optional) is connected, this function is
restricted.
8.2. Outdoor Unit Low Noise operation
The Outdoor Unit Low Noise operation lowers noise from the outdoor
unit. During this operation, the rotation number of the compressor
decreases and the outdoor unit fan rotates slowly.
Press to activate/deactivate the Outdoor Unit Low
Noise operation.
9. SETTINGS ON INSTALLATION
9.1. Remote controller custom code setting
By setting custom code of indoor unit and remote controller, you can
specify the air conditioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to
operate them separately, set the custom code (4 selections possible).
NOTES: If custom codes is di󰀨erent between the indoor unit and the
remote controller, the indoor unit cannot receive a signal from
the remote controller.
How to set the remote controller custom code
1. Press
until only the clock is displayed on the remote
controller display.
2. Press down
for more than 5
seconds.
The current custom code will be
displayed (initially set to A).
3. Press
to change the
custom code between A↔B↔C↔D.
* Match the custom code on the display
to the air conditioner custom code.
4. Press
again.
The custom code will be set.
The display will return to the clock
display.
To change the air conditioner custom code, contact an authorized
service personnel (initially set to A).
If you do not press any buttons for 30 seconds after the custom
code is displayed, the display returns to the clock display. In this
case, repeat the setting from step 2.
Depending on the remote controller, the custom code may return
to A when replacing the batteries. In this case, reset the custom
code as necessary. If you do not know the air conditioner custom
code, try each code until you nd the code which operates the air
conditioner.
Details on Demand Response mode
DR mode Description of operation in this mode
DR mode 1 Compressor o󰀨.
DR mode 2
electrical energy consumption in 30 minutes:
50 % or less
(compared with rated energy consumption)
DR mode 3
electrical energy consumption in 30 minutes:
75 % or less
(compared with rated energy consumption)
NOTES:
During the DR mode, the cooling or heating performance may be
reduced.
During the DR mode, only the following operations are valid.
- Turning o󰀨 the operation by
- O󰀨 timer operation
The Powerful operation is performed within the operable range of
the DR mode.
During the DR mode, the Filter sign will not display.
Timer setting error indicator will be prioritized over the DR mode
indicator.
If you have operational issues:
(1) Contact your electricity supplier to check whether they are activating
the DR mode.
(2) Is the air conditioner under the Demand controlling?
Yes
Contact your electricity supplier.
No Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to
your warranty card.)
or
Visit our website (www.fujitsugeneral.com.au).
While the Outdoor Unit Low Noise operation is activated,
on the remote controller is displayed.
The setting is preserved even if the air conditioner is turned o󰀨.
NOTES:
This operation cannot be performed simultaneously with the Fan
mode, Dry mode, and Powerful operation.
If the wired remote controller (optional) is connected, this function is
restricted.
8.3. 10 °C Heat operation
10 °C Heat operation maintains the room temperature at 10 °C so as to
prevent the room temperature to drop too low.
Press to activate the 10 °C Heat operation.
The indoor unit will emit 1 short beep and [ ] indicator on the
indoor unit will turn on.
Press to turn o󰀨 the air conditioner.
[ ] indicator will turn o󰀨.
NOTES:
During the 10 °C Heat operation, only
and are valid.
When the room temperature is warm enough, this operation will not
perform.
If the wired remote controller (optional) is connected, this function is
restricted.
9387081237_OM.indd 8 02-Apr-19 15:59:18