Installation Manual

En-15
Cooling Room Temperature Correction
Depending on the installed environment, the room tempera-
ture sensor may require a correction.
The settings may be selected as shown in the table below.
(... Factory setting)
Setting Description
Function
Number
Setting
Value
Standard
30
00
Slightly lower control 01
Lower control 02
Warmer control 03
Heating Room Temperature Correction
Depending on the installed environment, the room tempera-
ture sensor may require a correction.
The settings may be changed as shown in the table below.
(... Factory setting)
Setting Description
Function
Number
Setting
Value
Standard
31
00
Lower control 01
Slightly warmer control 02
Warmer control 03
Auto Restart
Enable or disable automatic system restart after a power
outage.
(... Factory setting)
Setting Description
Function
Number
Setting
Value
Yes
40
00
No 01
* Auto restart is an emergency function such as for
power failure etc. Do not start and stop the indoor unit
by this function in normal operation. Be sure to oper-
ate by the control unit, or external input device.
Indoor room temperature sensor switching function
(Only for wired remote controller)
The following settings are needed when using the wired
remote controller temperature sensor.
(... Factory setting)
Setting Description
Function
Number
Setting
Value
No
42
00
Yes 01
* If setting value is “00” :
Room temperature is controlled by the indoor unit tempera-
ture sensor.
* If setting value is “01” :
Room temperature is controlled by either indoor unit tem-
perature sensor or remote controller unit sensor.
Remote controller signal code
Change the indoor unit Signal Code, depending on the
remote controllers.
(... Factory setting)
Setting Description
Function
Number
Setting
Value
A
44
00
B01
C02
D03
External input control
“Operation/Stop” mode or “Forced stop” mode can be elected.
(... Factory setting)
Setting Description
Function
Number
Setting
Value
Operation/Stop mode
46
00
(Setting forbidden) 01
Forced stop mode 02
Setting record
Record any changes to the settings in the following table.
Setting Description Setting Value
Filter sign
Cooler room temperature correction
Heater room temperature correction
Auto restart
Indoor room temperature sensor
switching function
Remote controller signal code
External input control
After completing the FUNCTION SETTING, be sure to turn off
the power and turn it on again.
9318739022_IM.indb Sec1:159318739022_IM.indb Sec1:15 2010-11-2 15:25:222010-11-2 15:25:22