C150-E213-02EN Scanner Utility for Microsoft Windows <32bit> Version 8.
Introduction Thank you for purchasing the "Scanner Utility for Microsoft Windows V8.4". This software contains a TWAIN-compliant image scanner driver (simply called "driver" in this guide) and utilities. This guide provides a description summary of the driver, as well as a description of the installation method and procedures for appropriate use. Please read this guide before starting to use the software. In addition, read the README.
Trademarks MS-DOS, Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation. IBM PC/AT and DOS/V are registered trademark of International Business Machine Corporation. Adaptec is a registered trademark of Adaptec Inc. EZ-SCSI is a trademark of Adaptec Inc. Other product names are the trademarks or registered trademarks of the respective companies.
Organization This manual explains how to install and use this driver, and how to use the TWAIN scanning utility. • TWAIN This section gives an overview of the TWAIN specification. • Installation This section explains the procedure for installing the environments in which this driver may operate. • Using the Driver This section explains how to use the driver.
Contents 1. Outline .................................................................................................. 1 1.1 Characteristics of this Driver ....................................................................................1 1.2 Operating Environment.............................................................................................1 1.3 Explanatory Notes .....................................................................................................2 1.
4.8.1 Gray........................................................................................................................36 4.8.2 Image Filter ............................................................................................................38 4.8.3 DTC ........................................................................................................................40 4.8.4 When Color is specified ......................................................................................
1. Outline 1.1 Characteristics of this Driver • This driver complies with TWAIN regulations V1.8 (the latest version as of May 2000), which are global standards for image scanners. The driver can be used in all TWAINcompliant applications. • This driver also supports an image scanner that has the "double -sided scan" function. If the application supports continuous scan, a double -sided document can be scanned. 1.
1.3 Explanatory Notes The descriptions in this manual are prepared based on the following rules: ◊ Menus and buttons The menus and buttons used in the program description are enclosed in []. Example: [File] menu, [OK] button ◊ Keyboard The keytop indications comply with the standard keyboard of the Fujitsu FMV series. Major differences between the Fujitsu FMV keyboard and other keyboards are shown below.
1.4 Explanation of terms ◊ IPC option board IPC-2/2D in this guide refers to the IPC-2 and IPC-2D image processing circuit. IPC-3/3D in this guide refers to the IPC-3 and IPC-3D option board.
2. TWAIN 2.1 TWAIN TWAIN is the specification that defines the standard software protocol and application programming interface (API) for data exchange between a software application program and an image input device such as the image scanner. [TWAIN development background] In the past, development of a new scanner inevitably required the development of a compatible driver and a sample (demonstration) program exclusively designed for the new scanner.
•Application software (photo retouching software, etc) ‚Source manager (TWAIN.DLL/TWAIN_32.DLL, etc) ƒSource (Image scanner control of the driver, etc) Image scanner, etc.
3. Installation 3.1 Preparation 1. Check that the operating system is installed correctly. 2. Check that the SCSI adapter is connected to the computer. 3. Check whether the SCSI driver and ASPI manager are installed correctly and operating (For windows 2000, 4.60 or later) Note Version 4.01 or later of the ASPI Manager is required. Use Explorer or a similar program to check the version number of the WNASPI32.DLL file. The environment setup tools described later can be used for checking. 4.
Figure Fujitsu TWAIN group * For the FUJITSU Scanner Control Center, the Gamma Pattern Editor and the Firmware Updater, see section 6, 5, and 7 respectively.
3.3 Uninstall The uninstall process removes the software and returns the hard disk to its pre-installation state. 1. Click on [Start], followed by [Settings], and then [Control Panel]. The Control Panel is then displayed. 2. Double-click on "Add/Remove Programs" from the icon list of the Control Panel. The panel of properties of [Add/Remove Programs] is displayed. 3. Select "Scanner Utility for Microsoft Windows" from the "Install/Uninstall" list. 4. Click on the [Add/Remove] button.
4. Using the Driver 4.1 Selecting the Driver To use this driver from the TWAIN application, select "FUJITSU TWAIN32" from the TWAIN data source (driver) selection screen. For general application, the data source selection screen is displayed by selecting the [Select Scanner] or [Acquire ...] menu. Refer to the instruction manual for the application used for details.
4.2 Screen Configuration Figure Main Dialog The following pages contain the explanation and operation description for each part.
4.3 Displaying Driver Information ♦ Image scanner name The model name, option port name, and capacity of internal scanner memory (in units of megabytes) of the connected image scanner are displayed. If no image scanner is connected, this field is blank. To change the selected scanner, click the [Select ...] button to display a list of connected scanners and select a scanner from the list. The type of IPC option board is displayed if an image-processing option board is installed in the scanner.
♦ Data size The approximate amount of data per image when data is scanned in the present option. Note This value is the amount of uncompressed data. The size of the stored file will differ from this value and is usually smaller if image compression is chosen and the image is compressed. 4.4 Setting Information on Image Scanning ♦ Current side When a scanner that allows duplex scanning is used, specifies the page which sets the image scanning information.
♦ Paper Size Selects a paper size corresponding to the size of the document to be scanned. Select a standard paper size from the list or [Custom]. If [Custom] is selected, the "Custom Paper Size Setting" dialog appears. Enter the size of the document to be scanned. (In this case, specify the paper size by width x length for the scanning direction.) Some paper sizes may not be accepted by your device. See "Relevant Image Scanner Specification" in Appendix.
♦ Scan Type Selects the feeding device. The image scanner uses a document bed called the flat bed as well as an automatic document feeder (ADF) for feeding scanned document. The ADF usually enables the documents to be scanned only once. The flat bed allows scanning the same documents repeatedly. ♦ Flatbed Reads a document placed on the flat bed of the device. ♦ ADF (Front Side) Reads the document on the device's automatic document feeder (ADF). Here, only front side is read.
♦ Long page (front and backside) In the same case as that for scanning the front of a long page, this option is selected in order to scan the entire side of a long page whose length exceeds the vertical size of an A3 sheet. If this option is selected, the document is scanned in the "front to back to front to back…" order. Paper feeding method that is to be supported varies with the type of scanner. See "Relevant Image Scanner Specification" in the Appendix.
Color Scans data using 24 bits color. This mode is suitable for scanning color photograph and employs far more memory that Gray scale mode. Some versions of the scanner do not support this scanning mode. For details contact the retail store where the device was purchased. Automatic separation This option specifies whether to distinguish line drawing from photograph image during scanning.
♦ Halftone Selects the halftone pattern for halftone scanning from the built- in pattern list. Select the desired halftone pattern for displaying the obtained image. This setting is effective when "Halftone" or "Automatic Separation" is selected in "Image Mode". Dither Pattern 0 Executes pattern processing that is suitable for scanning a dark photograph. Dither Pattern 1 Executes pattern processing that is suitable for scanning a dark-colored document containing both text and photographs.
This parameter can be set if "Halftone" or "Automatic Separation" is selected for "Image Mode." ♦ Threshold: Sets the threshold value by which the black and the white of black-and-white images are distinguished. Specify a number in the range of 1 (bright) to 255 (dark). This parameter can be set only if "Black & White" is specified for "Image Mode." In addition, if "Auto Binary" is selected, the scanner will automatically use the appropriate threshold value. As a result, the set value cannot be changed.
♦ Contrast: Sets the contrast of light and shadow in a scanned image. Specify the contrast with a number in the range of 1 (low [soft]) to 255 (high [sharp]). The contrast can be set if "Gray Scale" is selected in "Image Mode." If this value is increased, the dark part of the image is shown darker and the light part is shown lighter. Some scanner models do not support this function. See "Relevant Image Scanner Specification" in Appendix. 4.
Progress indicator ♦ [Close] / [OK] Closes the dialog box without scanning. If a setting is changed, the changed setting is saved in the initial value file. ♦ [Reset] Restores the current setting values to the status immediately after the window is opened. ♦ [Help] Displays online help. When the [F1] key is pressed, help information regarding the item on which the cursor is placed is displayed. Note Depending on the application used help information may not be displayable with the [F1] key.
♦ [Advance] Displays the "advance dialog " for settings related to color variance and image processing. ♦ [Config] Displays the "basic scan dialog" for managing the settings file and for setting simple scan dialog switching. ♦ [About] Express the version of this driver by clicking this button. 4.6 Setting "Scanning Area" Specify the scan area in the preview window as follows: Setting: 1. Press the left mouse button to specify the origin (top left corner) of the scanning area.
4.7 Setting Options The "option dialog" is used to set device-specific functions and the items that differ depending on whether the scanner used supports them. The option specification is divided into "Rotation", "Job/Cache", "Generic", "Imprinter (Endorser)" and "Start Up".. The supported options depend on the scanner. See "Relevant Image Scanner Specification" in the Appendix. ( is displayed for options that cannot be used.) The option dialog in this driver is explained below.
The options are described below: 4.7.1 Rotation Figure Option dialog (Rotation) ♦ Flip Side Rotation Specifies the binding of the document when both sides are scanned using ADF. Book Outputs the scanned image for both sides as is. Select this option to scan documents bound on the left or right side. Fanfold Outputs the scanned image of the backside rotated 180 degrees. Select this option to scan documents bound on the top or bottom (Front side and backside are printed conversely.
♦ Rotation Degree Outputs the scanned image rotated to the right or left 90 degrees. 0.0 degree Outputs the scanned image as is. 90.0 degree Outputs the scanned image rotated 90 degrees to the right (clockwise). -90.0 degree Outputs the scanned image rotated 90 degrees to the left (counterclockwise). 180.0 degree Outputs the scanned image rotated 180 degrees (top and bottom reversed). ♦ Automatic Size and Skew detection Disable This option outputs the image as it was scanned.
4.7.2 Job/Cache Figure Option dialog (Job/Cache) ♦ Caching Specifies whether to pre-read (cache) when a document is scanned. This option enables faster scanning. If processing of the application being used slows down and scanning stops, this option can be used to prevent degradation of the scanning speed. (The effect, however, depends on the environment being used.) None Caching is not performed.
Ram cache Pre-reads the allowable amount based on the allocated memory size and stores the data in PC memory. A memory size between 1 and 200 MB can be set. Use Memory on Scanner Pre-reads using the memory installed in the scanner (displayed only if supported by the scanner). ♦ Batch Detection The application can detect documents on a specific type of form (special paper). The application must support this function. None No detection. Scanning is done without change.
♦ Double Feed Detection This option detects a double feed (occurs when two or more documents are sent) based on the set condition. If a double feed is detected when this setting has been turned on, the device will stop and an error message output. None Double feed detection is not performed. Hardware Setting A double feed is detected based on the device setting. Check thickness The thickness of the transmitted document is checked by the sensor in the device.
This option is valid only when the cache setting is set to [Use Memory on Scanner]. In addition, this option cannot be used unless it is supported by the scanner.
4.7.3 Generic Figure Option dialog (Generic) ♦ Unit/Scaling This option selects the unit for the scanning area and preview window. One inch is calculated as 25.4 millimeters. When inches are converted to millimeters, values are rounded off. Note The TWAIN specifications require that the data width be arranged in units of 32 bits. As a result, a difference of up to 31 dots can be included, depending on the value set.
4.7.4 Imprinter (Endorser) Figure Option dialog (Imprinter) ♦ Enable Imprinter (Endorser) Specifies enabling or disabling the imprinter function of the device. When the option is selected and scanning has been completed, the scanned originals are imprinted according to the instructions below. This applies only to the imprinter option. Therefore, the function is supported only in devices in which the imprinter option can be installed. See "Relevant Image Scanner Specification" described in the Appendix.
from the tail of strings against to the direction of scanning, designate “Bottom to Top” However, see the “Relevant Image Scanner Specification” described in the Appendix since the available settings depend on the device. ♦ Initial Value (Counter) Designates the initial count when the Imprinter String is set, including a counter value. See the "Relevant Image Scanner Specification" described in the Appendix since the programmable values range depends on the device.
%DD: The day is printed using two digits; for example, 03 for the 3rd day of the month and 26 for the 26th day of the month. %D: The day is printed using one or two digits; for example, 3 for the 3rd day of the month and 26 for the 26th day of the month. %HH: The hour is printed using two digits of the 24-hour clock; for example, 08 for 8:00 a.m. and 14 for 2:00 p.m. %H: The hour is printed using one or two digits of the 24-hour clock; for example, 8 for 8:00 a.m. and 14 for 2:00 p.m.
4.7.5 Start Up Figure Option dialog (Start Up) ♦ Power Mode − Quick Start Mode This mode keeps the lamp on regardless the scanner’s operating condition, which saves times for lamp to become steady. − Low Power Mode To save the power consumption, this mode turns the lamp off, if the scanner is not operated for 14minutes. ♦ Enable Low Speed Feeding This is to specify to obtain a high quality image. This function reduces times of start/stop during the scanning to obtain a smooth and high quality image.
− Enable Scanner Panel This is to specify whether the operator panel is enabled or not. If this is checked, button operation on the operator panel becomes effective. − Enable Scanner Dial Specifies whether the value indicated by the density dial on the scanner is reflected on scanning or not. This setting is valid when both “Enable Scanner Panel” and this checkbox are checked. With this density dial, the density can be set by five levels.
4.8 Setting Advance Options The "advance dialog" is used to set items related to image processing. The settings apply to device-specific functions and items that differ according to whether the scanner used supports them. The advance option specification is divided into "Color Variance", "Image Processing", and "Auto Binary". The supported options depend on the scanner. See "Relevant Image Scanner Specification" in the Appendix. ( is displayed for options that cannot be used.
The options are described below: 4.8.1 Gray Figure Advance dialog (density correction) ♦ Gamma Pattern This option corrects distortions from nonlinear image representation. Scanner sensors are generally designed to generate output linear to the density of the light reflected from the document. However, most output terminals do not produce output that has the desired linear relation to the input, and the resulting distortion must be corrected.
When "Download Pattern" is selected, the above dialog box opens. Select the gamma pattern download file to be used from the list of file names. Then, press the [OK] button. Correction will then be executed using the selected gamma pattern. If the gamma pattern download file has not been registered in the list of file names, use the [Add] button to register the file. See "Download Pattern File" for information about how to specify the file. When "Custom" is selected, a custom specification can be entered.
♦ Dropout Color This option enables scanning excluding the selected color information of green, red, or blue (the three primary colors of light). For example, to scan black characters framed in red, selecting red for scanning will scan only the black characters. ♦ Reverse This option specifies whether to reverse the black and white of a scanned image. If this option is selected, black and white are reversed by reversing the black and white pixels.
♦ Edge Processing This option specifies the sharpness of a scanned image. Select "None", "Edge Extract", or "Smoothing (Background Removal)". None Edge processing is not performed. Edge Extract This option outputs an image with the edge extracted. If this option is selected, the boundary between the black part and white part in a closed area is traced and the edge extracted. "DTC Variance" and "Edge Extract" are mutually exclusive.
4.8.3 DTC This option is valid only when "Simple auto binary" is set. Figure Advance dialog (DTC Mode) ♦ Scan mode This option selects one of the following two scan modes: [for OCR]: This mode is for text recognition applications where irregularity in the image is undesirable. [for Image]: This mode is for image scanning applications that scan images without prior smoothing. The specification changes the specifiable items and members for "Threshold Curve" and "Gamma Curve".
♦ Density curve This option specifies the relationship between the threshold value and the maximum density. This specification method depends on the [Scan mode] setting. In [for OCR] mode, use the slider to set the inclination and density level. To specify the value, drag the tab of the slider to the desired setting position. The current setting value is displayed on the right. (figure on the left) In [for Image] mode, select [Normal] or [Lightest].
♦ OCR Smoothing/ Background Removal The OCR smoothing is the function to make smooth the notched part of line-drawing, and the Background Removal is the function to remove the uneven background. These functions are enabled when it is selected. For further information, please refer to the User’s guide attached to the IPC board since the function to be operated is different by the type of IPC. At IPC-3/3D, [Noise Removal] and [OCR smoothing/ Background removal] is enabled exclusively.
4.8.4 When Color is specified For color devices, if Color is selected in the image type, dialog display changes as follows. Figure Advance dialog (Color) ♦ Shadow/Highlight Shadow : The highlight allows the darkest part of the document to be controlled. The higher the shadow value, the darker the image. Highlight : The highlight allows the brightest part of the document to be controlled. The higher the highlight value, the lighter the image.
Contrast : Sets the contrast of light and shadow in a scanned image. Specify the contrast with a number in the range of 1 (low [soft]) to 255 (high [sharp]). If this value is increased, the dark part of the image is shown darker and the light part is shown lighter. Some scanner models do not support this function. See "Relevant Image Scanner Specification" in Appendix. Brightness : Sets the brightness of the overall image. Specify the brightness with a number in the range of 1 (bright) to 255 (dark).
Figure Advance dialog (Quality) ♦ Image Emphasis This option specifies the sharpness of a scanned image. Select "None", "De-Screen" or "Emphasis". None Edge processing is not performed. Emphasis This option outputs an image with the edge emphasized. "Emphasis High", "Emphasis Mid", or "Emphasis Low" can be selected. If "Emphasis High" is selected, the image becomes sharper. If "Emphasis Low" is selected, the image appears less distinct.
De-Screen "De-Screen Level 1", "De-Screen Level 2", "De-Screen Level 3", or "De-Screen Level 4" can be selected. This option eliminate moirés patterns. To eliminate more effectively, higher level is selected. ♦ White Level Follower Select this option to scan a document whose background color is not white, such as a newspaper. Select "Auto", "Enable", or "Disable". When "Enable" is selected, the document is scanned using background follow-up (for line drawings).
4.9 Setting the Configuration Options These options are used to manage the setting files, and switch the basic scan dialog display. Press the [Config] button of the main dialog to open the [Configuration] dialog box shown below. Figure Option dialog box (simplified DTC) ♦ Setting Files The setting information of the scan conditions can be saved in a “Setting file.” Scan condition settings that have been set in advance in this dialog can be selected from the list of setting files.
♦ FTS File Information The information of the setting file selected in [Setting Files] is displayed. ♦ [Show this dialog next open] checkbox If this checkbox is checked, [Basic Scan Dialog] will be activated the next time the driver is activated. ♦ [OK] button Makes the new setting valid, closes this dialog box, and returns to the main dialog. ♦ [Add] button Adds the setting of the current driver to a setting file. Pressing the [Add] button opens the [File addition] dialog.
Filename: Specify the name of the file used to save the settings. ♦ [Delete] button Deletes unnecessary setting files. Select the setting file to be deleted and then press the [Delete] button. A confirmation dialog will be displayed. Press the [OK] button to delete the setting file. To cancel, press the [Cancel] button. ♦ [Help] button Displays online help.
4.10 Basic Scan Dialog The basic scan dialog contains only the minimum functions required for scanning. The detailed setting functions of the main dialog have been omitted. Scanning can be easily performed by selecting a registered setting file. The basic scan dialog is also useful for avoiding incorrect operations when standard work is performed.
♦ FTS File Information The contents of the selected file are displayed. ♦ [Scan] button Executes scanning based on the contents of the setting file. ♦ [OK] button Terminates without performing the scan operation. ♦ [Adjust] button Switches from the basic scan dialog to the main dialog. ♦ [Help] button Displays online help. ♦ [Show this dialog next open] checkbox If this checkbox is checked, the [Basic Scan Dialog] will be opened at the next startup.
4.11 Download Pattern File The "download pattern file" of this driver is a file that defines the patterns to be used by the scanner to execute various image processing. This file is available in the following two versions. Each version can be selected using the [Download Selection Dialog] that opens when [Download] is selected. The file is a text file that conforms to the following rules. Use an appropriate text editing program (for example, "Note Pad" in the operating system) to edit the file.
Example 8, 8, 128, 128, 128, 128, 128, 128, 128, 128, 255, 128, 128, 128, 128, 128, 128, 128, 255, 255, 128, 128, 128, 128, 128, 128, 255, 255, 255, 128, 128, 128, 128, 128, 255, 255, 255, 255, 128, 128, 128, 128, 255, 255, 255, 255, 255, 128, 128, 128, 255, 255, 255, 255, 255, 255, 128, 128, 255, 255, 255, 255, 255, 255, 255, 128, 53
♦ Gamma download pattern file Any user defined gamma correction processing can be performed by downloading the pattern from the gamma download file to the scanner. The defined pattern becomes effective when [Download Pattern] is selected for [Gamma Pattern]. Some models do not support this file. See "Relevant Image Scanner Specification" in Appendix. Although the standard extension of the file name is ".
Example 256, 256, 255, 254, 253, 252, 251, 250, 249, 248, 247, 246, 245, 244, 243, 242, 241, 240, 239, 238, 237, 236, 235, 234, 233, 232, 231, 230, 229, 228, 227, 226, 225, 224, 223, 222, 221, 220, 219, 218, 217, 216, 215, 214, 213, 212, 211, 210, 209, 208, 207, 206, 205, 204, 203, 202, 201, 200, 199, 198, 197, 196, 195, 194, 193, 192, 191, 190, 189, 188, 187, 186, 185, 184, 183, 182, 181, 180, 179, 178, 177, 176, 175, 174, 173, 172, 171, 170, 169, 168, 167, 166, 165, 164, 163, 162, 161, 160, 159, 158, 157,
5. Using the Gamma Pattern Editor 5.1 Start-up Click on "Start" and select "Download Pattern Editor" from "Scanner Utility for Microsoft Windows" under "Programs.
5.2 [File] menu ♦ [Load] This menu is used to read the Gamma Download file and display the graph and gradations. The name of the open file is displayed above the graph area. ♦ [Save] The gamma pattern currently being edited is saved in the file whose name is displayed above the graph area. If no filename is displayed, the pattern is named and saved in that file. ♦ [Save As] The gamma pattern currently being edited is named and saved in that file. The saved filename is then displayed above the graph area.
5.3 [Help] menu ♦ [About] Information related to this editor and its version number is displayed.
5.4 Gamma Pattern Editing ♦ Graph Area The graph area is a 256-dot × 256-dot white square area bordered by black lines, where the relationship between the input values of 0 to 255 (x axis) and output values of 0 to 255 (y axis) is indicated in blue lines. Each graph dot represents one division (unit). ♦ Gradation The input is displayed in black and white in 256 single -dot steps from 0 at the left border to 255 at the right border. The gamma function of the scanner is displayed.
6. How to Use the FUJITSU Scanner Control Center 6.1 Outline This software that is resident in the system continuously monitors the scanner connected and starts the target application in response to an instruction from the operation panel in the scanner. (Pressing the start button on the scanner starts the application that has been set in advance.) For applicable models, see "Relevant Image Scanner Specification" in the Appendix. 6.
Right-clicking the icon displays the following pop-up menu. Left-clicking the icon displays the scanner being connected as shown below. The scanner that has been monitored by this application is indicated with a check mark. 6.3 Pop-up Menu ♦ [Rescan Scanner] Rescans the scanner that is currently connected. A scanner that is not recognized by the OS cannot be found even though it is rescanned. ♦ [Option] Sets up the application to be started when the start button of the scanner is pressed.
♦ [Path] Specifies a file name of the application to be started with its absolute pathname. A file can be also selected directly by using the […] button. ♦ [Argument] Specifies an argument to be passed when starting the specified application. (This item can be omitted.) ♦ [Start in] Specifies a default folder for starting the application. A default folder can be also selected by using the […] button. (This parameter can be omitted.) ♦ [Run] Specifies the display size of the application to be started.
♦ [Use Plug-In] Checking this check box specifies a plug-in. (A plug-in is an additional program for adding a new function to the application.) ♦ [Setting] Sets a plug-in in accordance with the following procedure: • Pressing the [Setting] button after selecting a target plug-in name in the plug-in list displayed displays the plug-in setting screen. • Pressing the [OK] button after setting each item reflects the settings for the application to be started. ♦ [Install] A new plug-in can be installed.
Selecting "Yes" displays a dialog box below. (If "No" is selected, the function to start any application when the start button in this application is pressed is disabled.) Pressing the [OK] button after selecting one of function keys from F1 to F3 enables assigning a function key to the start button. If the [Cancel] button is pressed, the function key is not assigned to the start button.
Left-clicking the task tray icon displays connected scanner names on the pop-up menu. It is also possible to select a scanner on this menu. ♦ [Help] Displays help information concerning to this application. ♦ [About] Displays version information concerning to this application. ♦ [Exit] Terminates this application.
7. Using the Firmware Updater This application software is used to update the firmware installed in the scanner device. However, this application software is automatically executed when the driver installation is completed. If the software is executed at the installation, it is not necessary to execute again. This application software shall be used only for the following devices. Do not use for other devices. Applicable Devices: fi-4750, M4097D, fi-4750C Check items before use.
When the following dialog box appears, press the [OK] button. The firmware update has been completed successfully. Reactivate Windows.
8. Troubleshooting 8.1 Error Messages 8.1.1 Messages from the TWAIN Driver • • • • • The input value is outside the range. Cause: A value exceeding the range allowed for an input item was input. User response: Input a value inside the allowed range. Refer to the input item or the image scanner specification for the range. The input value is not acceptable. Cause: A value exceeding the range allowed for an input item was input. User response: Input a value inside the allowed range.
• The value for custom paper is higher than the maximum scan size. Width needs to equal 279 mm or less and length needs to equal 420 mm or less. • The value for custom paper is higher than the maximum scan size. Width needs to equal 11 inch or less and length needs to equal 16.53 inch or less. • The value for custom paper is higher than the maximum scan size. Width needs to equal xxx pixel or less and length needs to equal xxx pixel or less.
• Cannot specify Individual Setting with Gray Scale. • Cannot specify Long Page Scan with Gray Scale. Cause: Gray Scale and Individual Setting are specified at the same time. Gray Scale and Long Page Scanning are specified at the same time. User response: Uncheck Individual Setting when specifying Gray Scale. At Long Page scanning, select Black/white binary or Half tone for the [Image type]. • • • • • • Dither pattern file not found.
• • Cannot specify next words for filename. \:;?”<> |. Cause: The specified filename contains one or more of the following characters: \:;?”<> |. User response: Enter a file name that does not contain the above characters. Then, make the settings again. The image scanner cannot be found. Cause: Possible causes include the following: an image scanner that is not supported by this driver has been connected, no image scanner has been connected, or the cable is not connected.
• • • • • No paper in the ADF Cause: Although ADF was selected as the paper feeding method, no paper is found in the document tray. User response: Select another paper feeding method or set the document in the document tray. The hopper tray is open, or No paper in the ADF. Cause: The hopper tray cover is open, or there is no paper in the ADF. User response: Close the hopper tray cover, or load paper. Insuffic ient buffer memory size of scanner device for current scanning parameters.
• • • • • Ink cartridge is not installed in the imprinter properly. Please check it and try. Cause: The imprinter (Endorser) has no ink cartridge or the ink cartridge may be mounted improperly. User response: Check that the ink cartridge of the imprinter is mounted properly and scan again. Imprinter position is out of paper. Please check the imprinter position and try again. Cause: Printing is not available because the printing part is outside the paper width.
• • • • Download file not found. Cause: A file specified as a dither pattern or gamma pattern cannot be found. User response: Check that the download file is in the specified directory. Otherwise, use the file selection dialog to specify an available file. Illegal format or data in download file. Cause: The format of the specified download file is illegal or the data is incorrect. User response: User response: Use an editor to check file format and data. ASPI manager not found.
• • A general fault of the DAT_XXXXX response (internally). Cause: This is a program error that usually occurs during internal data transfer. This message involves the sub-messages described later. User response: Contact the retail store where the product was purchased or the nearest maintenance service center. A general fault of the DAT_XXXXX, MSG_SET, and unsupported type response. (Internally) Cause: This is a program error that usually occurs while making the internal data settings.
8.1.2 Error messages relating to gamma correction pattern editing • • • • Enter a positive decimal value. Cause: A value other than a number has been entered as the gamma correction value. Alternatively , 0 or a negative value has been entered. User response: Reenter a valid value. The file could not be created. Cause: The file for saving could not be created. There is insufficient space to save the file or the disk to which the file was to be saved is corrupted.
8.1.3 Messages concerning to FUJITSU Scanner Control Center • Failed to start-up the application. Check the setting of FUJITSU Scanner Control Center. • The setting of the path is blank. Check the setting of FUJITSU Scanner Control Center. • Can not find the specified file. Check if the specified path and file name is correct. • Can not find the specified work folder. Check if the specified path is correct. • Cause: The setting of the application may be inadequate.
• • Scanner could not find although it searched again. Check the connection of the scanner and retry again Cause: The scanner power may not have been turned on or the cable may have been connected incorrectly. Otherwise, the OS may not recognize the scanner. User response: Make sure that the scanner power has been turned on and the cable has been connected correctly, then retry rescanning. Or, check if the OS recognizes the scanner.
8.1.4. Messages relating to the Firmware Updater • The firmware updater is already running. Cause: The same application software is tried to execute concurrently. User response: Use the one already executed. • ASPI manager has not been installed. Please install the ASPI manager. • ASPI manager of unsupported revision has been installed. Please install the ASPI manager of the revision 4.1 or later. • • • • Cause: The ASPI manager has not been installed, or revision may be old.
• The applicable scanner is not connected or the driver is in use. Please connect the applicable scanner or close the application software using the driver. The process is cancelled. Cause: The scanner may not been connected properly or the driver may be used. User response: Check the connection of the device or close the application software if it is using the driver. Then execute this application software again. • Failed to load the Flashwt.dll. • Localize DLL version is different.
8.2 Device Trouble Related to Operation • The [Scan] button is pressed, but scanning is not performed. Cause: • Has the scanner power been turned on? Has the SCSI cable been connected correctly? Has the correct device type been selected using [Select TWAIN Input Device]? The scanner appears to be operating, but no image is displayed.
9. Appendix 9.
Product: M3093DG (fi-4320) Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed, scanner unit moving (flat bed) Automatic Document Feeder (ADF) simultaneous double -sided reading Light source: Xe discharge tube (Green) Basic resolution: Horizontal scanning: 400 dpi Vertical-scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 6001 , 400, 300, 240, 200, 150, 100 dpi With image processing option: 50 dpi to 800 dpi (at steps of 1 dpi) Grayscale levels (inte
Product: M3096GX1 (fi-4620S) Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed, scanner unit moving (flat bed), Automatic Document Feed (ADF) Light source: Xe discharge tube (Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning:400, 300, 240, 200 dpi Output resolution: Standard: 400, 300, 240, 200 dpi With image processing option: 50 dpi to 800 dpi (at steps of 1) Grayscale levels (internal): 8 bit 256 levels Grayscale output: Enabled (8
Product: M3097G1 Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed, scanner unit moving (flat bed), Automatic Document Feed (ADF) Light source: Fluorescent tube (Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning:400, 300, 240, 200 dpi Output resolution: Standard: 400, 300, 240, 200 dpi With image processing option: 50 dpi to 1,600 dpi (at steps of 1) Grayscale levels (internal): 8 bit 256 levels Grayscale output: Enabled (8 bits) Some
Product: M3097DG Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed, scanner unit moving (flat bed), Automatic Document Feed (ADF) Simultaneous double -sided reading Light source: Xe discharge tube (Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 600, 400, 300, 240, 200, 150, 100 dpi With image processing option: 50 dpi to 800 dpi (at steps of 1 dpi) Grayscale levels (internal): 8 bit
Product: M3099G, M3099GX Type: Desktop Image sensor: Reduced optical system Operating method: Automatic Document Feed (ADF), simultaneous double -sided reading Light source: Fluorescent tube (Green) Basic resolution: Horizontal scanning: 200 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 400, 300, 240, 200, dpi With image processing option: 50 dpi to 400 dpi (at steps of 1 dpi) Grayscale levels (internal): 8 bit 256 levels Grayscale output: Disabled Halftone Pat
Image processing function: Simplified Dynamic Threshold (SDTC) With image processing option Edge emphasis, Edge extraction, Automatic separation, Mirror image, Reverse image, Dynamic Threshold (DTC), Smoothing, Filtering, Noise removal Imprinter (Endorser): With imprinter (endorser) option (Reverse side, minimum left margin printing position of 20 mm) 1 Maximum number of characters to be printed: 20 characters Counter display range: 0 to 65535 (5 digits display) Direction (Printing): Top to Bottom Inter
Product: M3099GH Type: Desktop Image sensor: Reduced optical system Operating method: Automatic Document Feed (ADF), simultaneous double -sided reading Light source: Fluorescent tube (Green) Basic resolution: Horizontal scanning: 200 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 400, 300, 240, 200, dpi with image processing option: 50 dpi to 400 dpi (at steps of 1 dpi) Grayscale levels (internal): 8 bit 256 levels Grayscale output: Disabled Halftone Patterns:
Imprinter (Endorser): With imprinter (endorser) option (Reverse side, minimum left margin printing position of 20 mm) 1 Maximum number of characters to be printed: 20 characters Counter display range: 0 to 65535 (5 digits display) Direction(Printing): Top to Bottom Interface: SCSI-II Job control: Enabled Use of FUJITSU Scanner Control Center: Disabled 1 If 0 mm is specified as the endorser print position, printing will begin 20 mm from the edge of the page.
Product: fi-4640S Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed Flat bed, Automatic Document Feed(ADF) Long page scanning (297mm x 1387mm) Light source: Xe discharge tube(Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 800,700,600,500, 400, 300, 240, 200, 150, 100 dpi Output resolution: Standard: 50 dpi to 800 dpi (at steps of 1dpi) Grayscale levels (internal): 10 bit 1024 levels Grayscale output: Enabled (8 bits) Halftone Patt
Imprinter (Endorser): With imprinter option (Reverse side, minimum left margin printing position of 42 mm) 1 Maximum number of characters to be printed: 40 characters Counter display range: 0 to 65535 (at 5 digits display) 0 to 16777215 (at 8 digits display) Direction (Printing): Top to Bottom, Bottom to Top Interface: SCSI-II Job control: Enabled Double feed detection: Enabled Long page scanning: Enabled Use of FUJITSU Scanner Control Center: Enabled 1 If 0 mm is specified as the endorser print
Product: M4097D (fi-4750) Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed Flat bed, Automatic Document Feed(ADF), simultaneous double -sided reading Long page scanning (297mm x 1387mm) Light source: Xe discharge tube(Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 800,700,600,500, 400, 300, 240, 200, 150, 100 dpi Output resolution: Standard: 50 dpi to 800 dpi (at steps of 1dpi) Grayscale levels (internal): 10 bit 1024 levels Graysc
Imprinter (Endorser): With imprinter option (Reverse side, minimum left margin printing position of 42 mm) 1 Maximum number of characters to be printed: 40 characters Counter display range: 0 to 65535 (at 5 digits display) 0 to 16777215 (at 8 digits display) Direction (Printing): Top to Bottom, Bottom to Top Interface: SCSI-II Job control: Enabled Double feed detection: Enabled Long page scanning: Enabled (front side and both sides) Use of FUJITSU Scanner Control Center: Enabled 1 If 0 mm is spe
Product: fi-4750L Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed Flat bed, Automatic Document Feed(ADF), simultaneous double -sided reading Long page scanning (297mm x 1387mm) Light source: Xe discharge tube(Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 800,700,600,500, 400, 300, 240, 200, 150, 100 dpi Output resolution: Standard: 50 dpi to 800 dpi (at steps of 1dpi) Grayscale levels (internal): 10 bit 1024 levels Grayscale outp
Imprinter (Endorser): With imprinter option (Reverse side, minimum left margin printing position of 42 mm) 1 Maximum number of characters to be printed: 40 characters Counter display range: 0 to 65535 (at 5 digits display) 0 to 16777215 (at 8 digits display) Direction(Printing): Top to Bottom, Bottom to Top Interface: SCSI-II Job control: Enabled Double feed detection: Enabled Use of FUJITSU Scanner Control Center: Enabled 1 If 0 mm is specified as the endorser print position, printing will begin
Product: fi-4750C Type: Desktop Image sensor: LED(RGB) + Reduced optical system Operating method: Document fixed Flat bed, Automatic Document Feed(ADF), simultaneous double -sided reading Long page scanning (297mm×1387mm) Light source: LED (R, G, B) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 800,700,600,500, 400, 300, 240, 200, 150, 100 dpi Output resolution: Standard: 50 dpi to 800 dpi (at steps of 1dpi) Grayscale levels (internal): 10 bit 1024 levels Grayscale output
Gamma pattern: 3 internal types (can be downloaded) Image processing function: Simplified Dynamic Threshold (SDTC), Edge emphasis, Edge extraction, De-Screen, SEE(Selectable Edge Enhancement), Reverse image With image processing option Dynamic Threshold (DTC), Smoothing, Filtering, Noise removal, Automatic Separation Imprinter (Endorser): With imprinter option (Reverse side, minimum left margin printing position of 42 mm) 1 Maximum number of characters to be printed: 40 characters Counter display range
Product: M4099D (fi-4990) Type: Desktop Image sensor: Reduced optical system Operating method: Automatic Document Feed (ADF), simultaneous double -sided reading Long page scanning (297mm ×878mm) Light source: Fluorescent tube (White) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 400, 300, 240, 200, dpi With image processing option: 50 dpi to 400 dpi (at steps of 1 dpi) Grayscale levels (internal): 10 bit 1024 levels Gray
Imprinter (Endorser): With endorser option (Reverse side, minimum left margin printing position of 20 mm) 1 Maximum number of characters to be printed: 30 characters Counter display range: 0 to 65535 (at 5 digits display) 0 to 16777215 (at 8 digits display) (There is partly limitations by the revision of the scanner device.
Product: fi-4990C Type: Desktop Image sensor: Reduced optical system Operating method: Automatic Document Feed (ADF), simultaneous double -sided reading Long page scanning (297mm ×878mm) Light source: Fluorescent tube (White) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400, 300, 200 dpi Output resolution: Monochrome: 400, 300, 240, 200, 150, 100dpi Color : 400, 300, 200, 150, 100dpi Grayscale levels (internal): 10 bit 1024 levels Gray scale (8 bits) output: Enabled Ha
(There is partly limitations by the revision of the scanner device.
Product: M3091DC (fi-4110C) Type: Desktop Image sensor: Reduced optical system Operating method: Automatic Document Feed (ADF), simultaneous double -sided reading Light source: Fluorescent tube (White) Basic resolution: Horizontal scanning: 300 dpi Vertical scanning: 600 dpi Output resolution 1 : 50 dpi to 600 dpi (at steps of 1dpi) Grayscale levels (internal): 8 bit 256 levels Grayscale output: Enabled (8 bits) Halftone Patterns: Dither matrix (can be downloaded), Error diffusion Color
Job control: Disabled Double feed detection: Disabled 104
Product: M3092DC (fi-4210C) Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed Flat bed (FB), Automatic Document Feed (ADF), simultaneous double -sided reading Light source: Fluorescent tube (White) Basic resolution: Horizontal scanning: 600dpi (FB), 300 dpi (ADF) Vertical scanning: 600 dpi Output resolution 1 : 50 dpi to 600 dpi (at steps of 1dpi) Grayscale levels (internal): 10 bit 1024 levels Grayscale output: Enabled (8 bits) Halftone Patterns: Dither
Job control: Disabled Double feed detection: Disabled 106
9.2 Maintenance Service This section explains briefly how you can help us to provide you with high-quality maintenance service. Since it is practically impossible for the Fujitsu service staff to be aware of every detail of your daily scanning operation, please understand that our staff may sometimes be unable to answer your question immediately.
TWAIN Scanner/Driver Utility “Scanner Utility for Microsoft® Windows®” Users Guide 32 bit version First Edition June 2001 2nd Edition August 2001 All Rights Reserved, Copyright FUJITSU LIMITED 2001 • • • • The contents of this document may change for improvements without prior notice. Fujitsu takes no responsibilities for infringements of third parties’ patents or other rights that may stem from the use of the data in this document.