INSTRUCTION MANUAL CCD CAMERA CG-301 Series
WARNING – TO PREVENT RISK OF FIRE OR SHOCK, DO NOT EXPOSE THIS CAMERA TO RAIN OR MOISTURE. PRECAUTION : DO NOT REMOVE ANY COVER WHILE THE CAMERA IS OPERATING. PAL : USE ONLY RECOMMENDED POWER SUPPLY, 24 VAC (20.4 to 27.6 VAC) 50 Hz or 12VDC(10.2 to13.8VDC). NTSC : USE ONLY RECOMMENDED POWER SUPPLY, 24 VAC (20.4 to 27.6 VAC) 60 Hz or 12VDC(10.2 to13.8VDC). CAUTION : LENS MOUNT OF THE CAMERA IS “CS” MOUNT. CAMERA LENS MOUNT IS SHALLOW, SOME CAMERA LENSES MAY BOTTOM OUT AND DAMAGE TO THE CCD IMAGER.
CONTENTS Section Page IMPORTANT SAFEGUARDS 3 INTRODUCTION 5 CAUTIONS FOR OPERATION 5 EXTERNAL CONTROLS AND CONNECTORS 6 LENS ELECTRONIC CONNECTIONS MECHANICAL CONNECTION BACK FOCAL ADJUSTMENT 7 7 7 8 POWER CONNECTION AC POWER CONNECTION DC POWER CONNECTION 9 9 9 SETUP MENU SETTING METHOD SETTING OPERATION SETUP ITEMS MODE SELECT EXPOSURE SET. FUNCTION SET.
IMPORTANT SAFEGUARDS 1. Read Instructions–All the safety and operating instructions should be read before the camera is operated. 2. Retain Instructions–The safety and operating instructions should be retained for future reference. 3. Heed Warnings–All warnings on the camera and in the operating instructions should be adhered to. 4. Follow Instructions–All operating and use instructions should be followed. 5. Cleaning–Unplug the power unit from the wall outlet before cleaning.
14. Overloading–Do not overload wall outlet and extension cord, as this can result in a risk of fire or electric shock. 15. Object and Liquid Entry–Never push objects of any kind into the camera through openings, as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the camera. 16. Servicing–Do not attempt to service the camera yourself as opening or removing covers may expose you to dangerous voltage or other hazards.
INTRODUCTION Thank you for purchasing this product. This product is a multiple function and a high quality CCD camera developed considering a high-end security. The following functions are built-in: (1) Wide Dynamic Range function This function makes it possible to capture both high-luminance and low-luminance subjects. Dynamic Range of max.60 dB. (2) Day & Night function This is function to capture high quality color images during the day and clear B&W images at night.
EXTERNAL CONTROLS AND CONNECTORS 3 5 CAMERA MOUNT ADAPTER 7 4 6 8 9 1 2 10 3 BACK VIEW TOP/FRONT VIEW Fig.1 ① Lens Mount The camera has a standard CS lens mount but can use a C-mount lens when a C/CS-mount adapter is installed between the lens and camera. ② Back Focus Lock Screw Loosen to adjust the back focus to match the lens attached to the CS mount. Refer to the section on Back Focus Adjustment in this manual. ③ Camera Mounts Top or bottom mounting. Maximum thread length is 3/16-inch.
LENS This camera can accommodate DC voltage drive auto-iris lens. VIDEO signal controlled lens is not available. ELECTRONIC CONNECTIONS Table.1 shows wiring scheme for the 4pin Auto iris connector. Lens Connector Auto-iris Lens Table 1 Connector Pin No. 2 1 4 3 (View from wiring side of plug) Fig. 2 DC VOLTAGE DRIVE AUTO-IRIS LENS 1 CONT. ( ) 2 CONT.
BACK FOCAL LENGTH ADJUSTMENT The camera has been factory-adjusted for the proper back focal length using a standard CS Mount lens. However, when the lens is mounted, it may be necessary to readjust back focal length to match the lens being used. ALLEN WRENCH 10mm 50mm Approx.15 CAMERA Fig.4 CAUTION : If the back focus locking screw is tightened too strong, the thread section of “Lens Mount” may be damaged. To tighten the back focus locking screw, use a 1.5 mm ALLEN WRENCH.
POWER CONNECTION This camera uses 24VAC or 12VDC power supply for the main supply. CAUTION : Take care not to short-circuit the power line wire, when connecting the power-supply cord to the camera. AC POWER CONNECTION A main supply of 24VAC (20.4 to 27.6 VAC) 50 / 60Hz is required. This main supply must also have a minimum rating of 270mA. Remove the sheath at the end of power cord in the length of 10mm. Twist and straighten the wires, then insert the wires to three holes of the terminal.
SETUP MENU This product built in OSD function and can customize the camera setting. The menu list is shown in the following. MODE SELECT STANDARD DAY&NIGHT WIDE CASINO USER MODE RETURN END MAIN MENU EXPOSURE SET. MODE SELECT EXPOSURE SET. FUNCTION SET.
SYNC SELECT PHASE SHIFT SYNC MODE PHASE AUTO → RETURN Phase Value = 28 END *Only when AUTO is selected CHROMA RY GAIN BY GAIN RY HUE BY HUE RETURN → → → → -1 -2 1 1 END E-ZOOM ZOOM POSITION RETURN POSITION → OFF END *Only when the zoom magnification is selected MASKING MASK SETTING MASK → OFF MASK EDIT MASK ERASE RETURN END *Only when ON is selected for MASK TITLE EDIT TITLE TITLE TITLE EDIT RETURN → OFF END ABCDEFGHIJKLM NOPQRSTUVWXYZ abcdefghijklm nopqrstuvwxyz 0123456789-/ RETURN BS *
SETTING METHOD This camera has multiple functions, and can be adapted to a shooting place. There are 2 methods which are specified functions of the camera. (1) Setting method by using OSD(On-screen Display) function. Refer to the next section in details. (2) Setting method by using Direct-key function. This camera has Direct-key function. This function can control the following functions directly without displaying the menu.
SETTING OPERATION This camera has OSD function. To change settings on the menu, operate the following procedure. 1. Press and hold down the SW for 2 seconds or more. The SW on the rear panel is used. (Fig.1 ⑧) 2. MAIN MENU appears on the monitor as shown in Fig.7-5. 3. Move the cursor to an item you want to change by using the SW. The menu of the selected item is displayed. The SW can be used as direction key. (Fig.7-2) 4. Select a parameter you want to change and specify it. 5.
Parameters of each mode is shown in Fig.7-7,7-8,7-9,7-10. STANDARD FUNCTION SET. EXPOSURE SET. AE MODE LEVEL FLICKERLESS AGC SENS UP DAY&NIGHT DETECT TIME FILTER LIMIT RETURN → NORMAL → 0 → OFF → ON → 4 → COLOR → 5sec → OFF SYNC SELECT WHITE BALANCE CROMA GAMMA E-ZOOM MASKING TITLE → AUTO → AUTO → → NORMAL → → → RETURN END END Fig. 7-7 Setting parameters of STANDARD DAY&NIGHT FUNCTION SET. EXPOSURE SET.
(2) EXPOSURE SET. In this menu, the exposure system of the camera can be specified. There are 2 kinds of EXPOSURE SET. menu. A. AE MODE other than MANUAL EXPOSURE SET. AE MODE LEVEL FLICKERLESS AGC SENS UP DAY&NIGHT DETECT TIME FILTER LIMIT RETURN B. MANUAL is selected for AE MODE EXPOSURE SET. → → → → → → → → WD 0 OFF ON 4 AUTO 5 sec 10min END AE MODE LEVEL SHUTTER SPEED AGC SENS UP DAY&NIGHT DETECT TIME FILTER LIMIT RETURN → MANUAL → 0 → 1/60 → ON → OFF → AUTO → 5 sec → 10min END Fig.
DAY & NIGHT This item specifies the switch between Color and BW picture. AUTO : Auto mode enables the camera to switch between Color and BW picture in response to light condition. COLOR : Fixes to Color picture. BW : Fixes to BW picture. EXT. : This mode allows the camera to control by the external signal. Refer to the section on EXTERNAL CONTROL INPUT TERMINAL in this manual. Note) When OFF is selected for AGC, AUTO mode is not available.
(3) FUNCTION SET. In this menu, functions other than exposure system can be specified. EXPOSURE SET. SYNC SELECT WHITE BALANCE CROMA GAMMA E-ZOOM MASKING TITLE → → AUTO → → NORMAL → → → RETURN END Fig.9-1 FUNCTION SET. menu (3-1)SYNC SELECT This camera supports the synchronization mode such as line lock and internal. PHASE SHIFT SYNC SELECT SYNC MODE → AUTO PHASE → Phase Value = 27 RETURN END Fig.9-2 SYNC SELECT menu SYNC MODE The synchronization mode can be selected.
(3-2) WHITE BALANCE WHITE BALANCE You can select one of 4 modes for white balance adjustment as follows. AUTO, HOLD, INDOOR (Approx. 2800K), OUTDOOR (Approx. 6000K) AUTO : The white balance is adjusted automatically to provide the optimum picture. HOLD : In this mode, the WB gain just before changing to this mode is kept. INDOOR, OUTDOOR : These modes are the fixed WB gain. Setting procedure for HOLD 1. Image a subject. Move the cursor to WHITE BALANCE and select AUTO. 2.
(3-5) E-ZOOM This camera built in electronic zoom, electronic panning and electronic tilting function. In this menu, these functions is specified. E-ZOOM ZOOM POSITION RETURN POSITION → 2.0 → END Fig.9-5 E-ZOOM menu ZOOM The zoom magnification is selected from the following. OFF, 1.5, 2.0, 2.5 Note) When 1.5, 2.0 or 2.5 is selected, WD and MASKING function is not available. POSITION When the zoom magnification is selected for ZOOM, the position of the image can be adjusted. Adjusting procedure 1.
3. The pointer is displayed on the monitor screen. The area of a mask can be edited by using this pointer. At first, move the cursor to the upper left position you want to make a mask and press the SW. Next, move the cursor to the lower right position you want to make a mask and press the SW. In the above procedure, a mask can be made. MASK ERASE The made mask is erased. Erasing procedure 1. Move the cursor to MASK ERASE. 2. The made mask is erased by pressing the SW.
(4) CAMERA SETUP This camera has an external control input interface (RS-485). All parameters and adjustments can be changed from an external unit. Refer to the section on External Control Input Terminal in details. In this menu, setting of the communication, LED and Switch can be selected. CAMERA SETUP → 1 → 4800 → ON → ON ADDRESS COM SPEED LED SWITCH RETURN END Fig.10 CAMERA SETUP menu ADDRESS The number to identify two or more cameras is specified. It is possible to communicate up to 30.
(6) MODE SAVE Current settings can be saved. Saved settings can read by selecting USER MODE of MODE SELECT. MODE SAVE CURRENT SETTINGS ARE SAVED. OK CANCEL Fig.12 MODE SAVE menu Operation procedure 1. After changing parameters and adjustments, move the cursor to MODE SAVE and press the SW. MODE SAVE menu is displayed. 2. Move the cursor to OK and press the SW. Parameters and adjustments are saved. 3. The screen automatically reverts to the MAIN MENU when the save of setting ends.
(8) INITIALIZE Present settings are reset to the factory default settings. INITIALIZE ALL SETTINGS ARE IINITIALIZED OKFig. CANCEL MENU 8 INITIALIZE Fig.14 INITIALIZE menu Operation procedure 1. Move the cursor to INITIALIZE and press the SW. INITIALIZE menu is displayed. 2. Move the cursor to OK and press the SW. All parameters and adjustments are reset to the factory default settings. 3. The screen automatically reverts to MAIN MENU when the initialization is finished.
EXTERNAL CONTROL INPUT TERMINAL This camera has an external control input terminal and can be operated remotely by supplying a control signal to this terminal. CONNECTIONS Connections of control signals are as follows. Pin1 Pin7 Magnified Figure Fig.16 Pin No. 1 2 3 4 5 6 Description A (+) B (-) GND A (+) B (-) GND 7 D&N Control Signal Input If you operate cameras remotely by using this terminal, connect the following enclosed cable. We recommend to extend it with a twisted pair cable.
SETUP To make up the camera system with RS-485, do the following procedure. Setting procedure 1. Connect the cable for each camera. 2. Terminate the camera installed in the end of the system. Turn off the termination of other cameras. Refer to Fig.1 ⑥ 3. Set the address number for each camera on CAMERA SETUP menu. Notice so that the number is not repeated. 4. Set the communication rate on CAMERA SETUP menu. Select the same rate for each camera.
SPECIFICATIONS Model Name CG-301 TV System NTSC PAL Power AC24V(±15%) / DC12V(±15%) Power Consumption 270mA(24VAC) / 390mA(12VDC) Imager 1/3” Image Format vertical double density Interline transfer CCD Picture Elements (active) Approx. 380K pixels Approx. 440K pixels Synchronization Internal / LineLock Signal to Noise Ratio 48dB(AGC off, weighting) Video Output 1.0Vp-p/ Composite (75ohms) 480TV Lines (Color) 530TVLines(BW) 1.0Lux(Color) 0.1Lux (BW) 0.025Lux(SENSup x40 Color) (at F1.
FUJITSU GENERAL LIMITED 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan