AGU9RLF Operation Manual

En-9
TIMER OPERATION
To Use the PROGRAM timer
You can set an integrated ON–OFF or OFF–ON timer. Either of the timer whose con¿ gured starting time is closer to the current time
works ¿ rst, and the order of timer operation is displayed as follows:
Timer Indicator on remote controller display
ON–OFF timer
OFF–ON timer
The timer that is set later starts counting down after the counting down of the preceding timer is ¿ nished.
Notes:
If you change the setting value for the timer after the program timer is set, the counting down of the timer will be reset at that moment.
Time setting for each combination should be within a span of 24 hours
.
To Use the SLEEP timer
1
Press the SLEEP timer button (Fig. 5
A
) to activate the SLEEP timer.
OPERATION indicator and TIMER indicator on the indoor unit turns on.
2
Adjust the time by pressing the SELECT button (Fig. 5
G
) within about 5 seconds,
while the clock indicator is blinking.
(About 5 seconds later, the remote controller display returns to standby screen.)
Each time you press the button, the time changes as follows:
9.07.05.03.02.01.00.5
hours(30 min.)
To repeat the timer, press the SLEEP timer button when indicator is not displayed on the remote controller display.
To help you to fall asleep comfortably and prevent excessive warming or cooling in sleep, the SLEEP timer controls the temperature
setting automatically in accordance with the set time shown as follows. The air conditioner completely turns off after the set time has
elapsed.
In HEAT mode
Set
temperature
Set time
1 hour
Set time
1 hour
1.5 hour
30 min.
2 °F (1 °C)
4 °F
(2 °C)
6 °F
(3 °C)
8 °F (4 °C)
4 °F
(2 °C)
2 °F (1 °C)
In COOL or DRY mode
To Use the ON timer or OFF timer
1
Turn on the indoor unit by pressing the START/STOP button. (Fig. 5
1
).
OPERATION indicator on the indoor unit turns on. If the indoor unit is already operating, skip this step.
2
Press the ON timer button (Fig. 5
F
) or the OFF timer button. (Fig. 5
E
).
Clock indicator on the remote controller display starts blinking, and TIMER indicator on the indoor unit turns on.
3
Adjust the time by pressing the SELECT button (Fig. 5
G
) within about 5 seconds,
while the clock indicator is blinking.
(About 5 seconds later, the remote controller display returns to standby screen.) To cancel the timer and return to the normal operation,
press the CANCEL button.To redo the timer setting, perform step 2 and 3.
9378532076_OM.indb 9 9/24/2013 4:35:27 PM