Drain installation3. 2.
CAUTION
Perform drain work in accordance with this Manual, and ensure that the drain water
is properly drained. If the drain work is not carried out correctly, water may drip down
from the unit, wetting the furniture.
When the outdoor temperature is 32 °F or less, do not use the accessory drain pipe
and drain cap. If the drain pipe and drain cap are used, the drain water in the pipe may
freeze in extremely cold weather. (Reverse cycle model only)
Outdoor unit to be fasten with bolts at the four places indicated by the arrows without fail.
Bottom side
Drain cap mounting place
Drain pipe mounting place
Since the drain water À ows out of the outdoor unit during heating operation, install the
drain pipe and connect it to a commercial 16 mm (5/8 in.) hose. (Reverse cycle model
only)
When installing the drain pipe, plug all the holes other than the drain pipe mounting hole
in the bottom of the outdoor unit with putty so there is no water leakage. (Reverse cycle
model only)
Drain pipe mounting hole
Base
Drain pipe
Installation dimensions3. 3.
CAUTION
Install the unit where it will not be tilted by more than 3Û. However, do not install the
unit with it tilted towards the side containing the compressor.
When installing the outdoor unit where it may exposed to strong wind, fasten it
securely.
Decide the mounting position with the customer as follows:
(1) Install the outdoor unit in a location which can withstand the weight of the unit and
vibration, and which can install horizontally.
(2) Provide the indicated space to ensure good airÀ ow.
(3) If possible, do not install the unit where it will be exposed to direct sunlight.
(If necessary, install a blind that does not interfere with the airÀ ow.)
(4) Do not install the unit near a source of heat, steam, or À ammable gas.
(5) During heating operation, drain water À ows from the outdoor unit.
Therefore, install the outdoor unit in a place where the drain water À ow will not be
obstructed. (Reverse cycle model only)
(6) Do not install the unit where strong wind blows or where it is very dusty.
(7) Do not install the unit where people pass.
(8) Install the outdoor unit in a place where it will be free from being dirty or getting wet by
rain as much as possible.
(9) Install the unit where connection to the indoor unit is easy.
Single outdoor unit installation3. 3. 1.
When the upward area is open
• When there are obstacles at the back side.
100 mm (4 in.)
or more
INSTALLATION WORK3.
Please obtain the approval of the customer when selecting the location of installation
and installing the unit.
Selecting an installation location3. 1.
WARNING
Securely install the outdoor unit at a location that can withstand the weight of the unit.
Otherwise, the outdoor unit may fall and cause injury.
Be sure to install the outdoor unit as prescribed, so that it can withstand earthquakes
and typhoons or other strong winds. Improper installation can cause the unit to topple
or fall, or other accidents.
Do not install the outdoor unit near the edge of a balcony. Otherwise, children may
climb onto the outdoor unit and fall off of the balcony.
CAUTION
Do not install the outdoor unit in the following areas:
Area with high salt content, such as at the seaside. It will deteriorate metal parts,
causing the parts to fail or the unit to leak water.
Area ¿ lled with mineral oil or containing a large amount of splashed oil or steam,
such as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the
unit to leak water.
Area that generates substances that adversely affect the equipment, such as
sulfuric gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed
joints to corrode, which can cause refrigerant leakage.
Area containing equipment that generates electromagnetic interference. It will
cause the control system to malfunction, preventing the unit from operating
normally.
Area that can cause combustible gas to leak, contains suspended carbon ¿ bers or
À ammable dust, or volatile inÀ ammables such as paint thinner or gasoline. If gas
leaks and settles around the unit, it can cause a ¿ re.
Area that has heat sources, vapors, or the risk of the leakage of À ammable gas in
the vicinity.
Area where small animals may live. It may cause failure, smoke or ¿ re if small
animals enter and touch internal electrical parts.
Area where animals may urinate on the unit or ammonia may be generated.
Please install the outdoor unit without slant.
Install the outdoor unit in a well-ventilated location away from rain or direct sunlight.
If the outdoor unit must be installed in an area within easy reach of the general public,
install as necessary a protective fence or the like to prevent their access.
Install the outdoor unit in a location that would not inconvenience your neighbors, as
they could be affected by the airÀ ow coming out from the outlet, noise, or vibration. If it
must be installed in proximity to your neighbors, be sure to obtain their approval.
If the outdoor unit is installed in a cold region that is affected by snow accumulation,
snow fall, or freezing, take appropriate measures to protect it from those elements. To
ensure a stable operation, install inlet and outlet ducts.
Install the outdoor unit in a location that is away from exhaust or the vent ports that
discharge vapor, soot, dust, or debris.
Install the indoor unit, outdoor unit, power supply cable, connection cable, and remote
control cable at least 1 m (40 in.) away from a television or radio receivers. The
purpose of this is to prevent TV reception interference or radio noise. (Even if they are
installed more than 1 m (40 in.) apart, you could still receive noise under some signal
conditions.)
Branch switch and
circuit breaker
Branch switch and
circuit breaker
1 m (40 in.) or more
1 m (40 in.) or more
If children under 10 years old may approach the unit, take preventive measures so
that they cannot reach the unit.
Keep the length of the piping of the indoor and outdoor units within the allowable
range.
For maintenance purposes, do not bury the piping.
9374747146_IM.indb 5 19/11/2556 11:48:28