AOU45RLXFZ Installation Manual

En-11
6. 1. How to connect the wire to the terminals
When stripping off the coating of a lead wire, always use a special tool such as a wire
stripper. If there is no special tool available, carefully strip the coating with a knife etc.
1-3/16 in. (30 mm)
1-15/16 in.(50 mm)
Earth wire
Power supply cable
and connection cable
How to connect wiring to the terminal
Caution when wiring cable
(1) Use ring type terminals with insulating sleeves as shown in the gure to connect to
the terminal block.
(2) Securely clamp the ring type terminals to the wires using an appropriate tool so that
the wires do not come loose.
(3) Use the speci ed wires, connect them securely, and fasten them so that there is no
stress placed on the terminals.
(4) Use an appropriate screwdriver to tighten the terminal screws. Do not use a
screwdriver that is too small, otherwise, the screw heads may be damaged and
prevent the screws from being properly tightened.
(5) Do not tighten the terminal screws too much, otherwise, the screws may break.
(6) See the table below for the terminal screw tightening torques.
Sleeve
Strip : 3/8 in. (10 mm)
Ring type terminal
Wire
Screw with special washer
Ring type terminal
Terminal blocks
Screw with special washer
Wire
Ring type terminal
Tightening torque [lbf·in. (N·m)]
M4 screw 10.6 to 15.9 (1.2 to 1.8)
M5 screw 17.7 to 26.5 (2.0 to 3.0)
6. 2. Connection diagrams
45 model
1
2
3
1
2
3
G
G
G
1
2
3
1
2
3
G
G
1
2
3
1
2
3
G
1
2
3
G
L1
L2
1
2
3
G
G
1
2
3
G
1
2
3
G
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT A
INDOOR UNIT B
INDOOR UNIT C
INDOOR UNIT D
INDOOR UNIT E
TERMINAL
TERMINAL
UNIT A
UNIT B
UNIT C
UNIT D
UNIT E
TERMINAL
TERMINAL
TERMINAL
TERMINAL
DISCONNECT SWITCH
(Locally purchased)
(Inter-unit)
Power lines
Grounding
line
Grounding
line
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
Grounding
line
Grounding
line
Grounding
line
Power supply line
Single-phase, 208/230 V
DISCONNECT SWITCH
(Locally purchased)
DISCONNECT SWITCH
(Locally purchased)
DISCONNECT SWITCH
(Locally purchased)
DISCONNECT SWITCH
(Locally purchased)
36 model
1
2
3
1
2
3
G
G
G
1
2
3
1
2
3
G
G
1
2
3
1
2
3
G
1
2
3
G
L1
L2
1
2
3
G
G
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT A
INDOOR UNIT B
INDOOR UNIT C
INDOOR UNIT D
TERMINAL
TERMINAL
TERMINAL
TERMINAL
DISCONNECT SWITCH
(Locally purchased)
DISCONNECT SWITCH
(Locally purchased)
DISCONNECT SWITCH
(Locally purchased)
DISCONNECT SWITCH
(Locally purchased)
TERMINAL
UNIT A
UNIT B
UNIT C
UNIT D
(Inter-unit)
Power lines
Grounding
line
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
208/230 V
Grounding
line
Grounding
line
Grounding
line
Power supply line
Single-phase, 208/230 V
9380545101-06_IM_3L.indb 119380545101-06_IM_3L.indb 11 2018/6/20 14:01:532018/6/20 14:01:53