P3PC-E567-01EN fi-4530C Image Scanner Getting Started
CONTENTS ■ Regulatory Information ........................................................ ii ■ Note, Liability ....................................................................... iv ■ Safety Precautions ................................................................ v Chapter1 PREPARING THE SCANNER.................................. 1 1.1 Checking the Contents of the Scanner Package............. 1 1.2 Names of Parts ................................................................... 1 1.
INTRODUCTION Thank you for purchasing the fi-4530C Duplex Color Scanner product. This document describes how to handle fi-4530C Duplex Color and basic operation methods. Before you start using fi4530C Duplex Color be sure to thoroughly read this manual to ensure correct use. The "Operator’s Guide" is stored on the Setup Disk.
International ENERGY STAR® Program As an ENERGY STAR® Partner, PFU LIMITED has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. The International ENERGY STAR® Office Equipment Program is an international program that promotes energy saving through the penetration of energy efficient computers and other office equipment. The program backs the development and dissemination of products with functions that effectively reduce energy consumption.
Manufacturer Symbols Used In This Manual PFU LIMITED Image Products Sales Dept., Imaging Products Division, Products Group Solid Square East Tower, 580 Horikawa-cho, Saiwai-ku, Kawasaki-shi Kanagawa 212-8563, Japan Phone : (81-44) 540-4538 All Rights Reserved, Copyright© PFU LIMITED 2003 ATTENTION This symbol alerts operators to particularly important information. Be sure to read this information. This symbol alerts operators to helpful advice regarding operation.
■ Safety Precautions Turn the scanner OFF if it is damaged. WARNING Do not damage the AC cable. A damaged AC cable may cause fire or electric shock. Do not place heavy objects on AC cables, or pull, bend, twist, heat, damage or modify AC cables. Also, do not use damaged AC cables or power plugs, and AC cables or power plugs when the wall socket is loose. Use only specified AC cables and connector cables Use only specified AC cables and connector cables.
CAUTION Do not install the scanner on unstable surfaces. Install the scanner on a desk so that none of its parts protrude outside of the desktop. Also, make sure that the scanner is installed on a flat, level surface. Do not install the scanner on unstable surfaces. Install the scanner on a level surface that is free of vibration to prevent it from falling. Install the scanner on a strong surface that will support the weight of the scanner and other devices. Do not block the ventilation ports.
Chapter1 1.1 PREPARING THE SCANNER Checking the Contents of the Scanner Package When you unpack the scanner package, make sure that the package contains all the parts on the list included in the package. If any parts are missing or defective, contact your sales representative. Handle the scanner and accessories with care. ■ Removable Parts The following shows the parts that can be removed from the scanner. ADF paper chute Sheet guide Pad ASSY 1.
. z Name Function Function No. display Indicates the function No. and error status. Buttons Function Changes the Function activated by the Send to button (*). Send to Scan Launches the linked application software (*). Power button Turns the scanner ON and OFF. - Lights when the scanner is turned ON. LED *) About the settings on the launcher, refer to FUJITSU TWAIN32 scanner driver help and the "fi-4530C Operator’s Guide" on the Setup CD-ROM. ■ Indications on the Function No.
Chapter2 2.1 INSTALLATION OF THE SCANNER Installing the Scanner 1. Place the scanner at its installation site. For details on the scanner's dimensions and required installation space, refer to "fi-4530C Operator’s Guide" "7.2 Installation Specifications" on the Setup CD-ROM. 2. Attach the ADF paper chute. Hold the ADF paper chute and insert its tabs into the holes on the rear side of the scanner as shown in the figure below so that the side guides face up. 3) Insert the AC cable into the power outlet.
2. Connect the other end of the USB interface cable to your PC. 3. Press down the power button on the operator panel to turn on the scanner. 4. Turn on your PC. ATTENTION Use the USB interface cable provided as an accessory for the scanner. Operation with a commercially available USB cable is not guaranteed. When connecting to a USB hub, be sure to connect to the hub nearest your computer (first stage). If you connect it to a USB hub from the second stage onwards the scanner may not operate correctly.
ID No. • There are two types of FUJITSU TWAIN 32: One of the following driver software will be automatically installed according to your Operating System (OS). Description 0 to 7 Can be set as the ID 8, 9 Used for the factory default value (SCSI ID = 5). For Windows 98, Windows Me, Windows 2000, and Windows XP: 3. Press the power button to turn ON the scanner. FUJITSU TWAIN32 V9 When the scanner is turned ON, the SCSI ID set at step 2 is enabled. For Windows 95, Windows NT 4.
5. Click [TWAIN Driver] on the window below. . 3. Insert the Setup CD-ROM into the CD drive. ⇒ appears. ATTENTION This screen may not appear when the "Autoplay" setting of your PC is OFF. In this case, run "Install.exe" in this CDROM directly by the "Explorer" or "My Computer". 6. Select a language used for installation on [Choose Setup Language] window and click [OK]. 4. Click [INSTALL PRODUCTS]. 7. Install the application following the instructions on the window. 8.
2. Click [INSTALL PRODUCTS]. ATTENTION Depending on the OS, the following operations may be necessary. For Windows 98: When a request for inserting the CDROM of Windows 98 appears, insert it into the CD drive and click the [OK] button. For Windows 2000: When [Digital Signature not Found] appears, click [Yes]. For Windows XP: 1. When [Found New Hardware Wizard] appears, confirm that the Setup CD-ROM is set in the CD drive, then click the [Next] button. 2.
6. When the [InstallShield Wizard Complete] window appears, click [Finish] 4. Select "FUJITSU fi-4530Cdj" or "FUJITSU TWAIN32" on the dialog box appeared. HINT For Windows 98, Windows Me, Windows 2000, Windows XP: [FUJITSU fi-4530Cdj] For Windows 95, Windows NT 4.0: [FUJITSU TWAI32] ATTENTION For finishing the installation, it may be necessary restart to your computer. Follow the instructions on the window. 5. Select [To View...] from the [Scan] menu. 6. Set scanning resolution, document size, etc.
7. Documents are scanned, and the scanned images are displayed on the [ScandAll 21] window. 2. Turn on your PC and log on to Windows. . ATTENTION When using Windows NT 4.0, Windows 2000 or Windows XP, log on as a user with "Administrator" privileges (privileges of the administrator of your PC). The scanner may be detected automatically. If so, [Found New Hardware Wizard] (or [Add/Remove Hardware Wizard]) will appear. Click [Cancel] to close the Wizard window.
4. Click [INSTALL PRODUCTS]. ATTENTION Depending on the OS, the following operations may be necessary. For Windows 98: When a request for inserting the CDROM of Windows 98 appears, insert it into the CD drive and click the [OK] button. For Windows 2000: When [Digital Signature not Found] appears, click [Yes]. For Windows XP: 1. When [Found New Hardware Wizard] appears, confirm that the Setup CD-ROM is set in the CD drive, then click the [Next] button.. 2.
5. Enter required information, then click [Next >] button. 2. Click [INSTALL PRODUCTS] . 3. Click [QuickScan PRO (Trial)] on the window below. ATTENTION "QuickScanTM Pro" included in the Setup CD-ROM is an evaluation version. For further use after expiration of the evaluation period (up to 30 launches), it is necessary to purchase a fully functional version of QuickScanTM Pro. (When you install the evaluation version, do not change the Serial Number already displayed.) 6.
3. Select [Preview Settings...] from the [Scan] menu. Set the scan resolution, paper size and other scanning conditions, and then click [OK]. Error Recovery Guidance ■ Installing Error Recovery Guidance When any error occurs in the scanner, this Guidance automatically displays the solutions for troubleshooting on its window. 1. Insert the Setup CD-ROM into the CD drive. ⇒ appears. 2. Click [INSTALL PRODUCTS]. 4. Load the documents on the scanner.
4. Select a language used for installation on [Choose Setup Language] window and click [OK]. Adobe® Acrobat® ■ Installing Adobe Acrobat Install Adobe Acrobat by the following procedure from the "Adobe Acrobat 5.0 CD-ROM" provided with the scanner. 5. Install the application following the instructions on the window. Adobe Acrobat is required for displaying the manuals stored on the Setup CD-ROM. It is also possible to set Adobe Acrobat to display scanned images working together with the scanner.
3. The following window appears. Click the [Acrobat 5.0] button, then click the [Install Adobe Acrobat 5.0] button shown below. ⇒ The Setup window appears and the installation will be started. 4. The setup window appears. Install Adobe Acrobat following the instructions on the window. HINT 14 For details on installation of Adobe Acrobat 5.0, read the description that is displayed by clicking the [Before you install] button in the screen at Operation 3. For details on how to use Adobe Acrobat 5.
Appendix1 TROUBLESHOOTING ■ Troubleshooting checklist Symptom Scanner does not turn on. Check this item Remedy Have you pushed the power button? Push the power button. Are the AC cable and AC adapter properly connected to the scanner? Correctly connect the AC cable and the AC adapter. Disconnect the AC cable and the AC adapter from the scanner, then connect them again.
Symptom Double-feed frequently occurs. Paper is not fed (pick error occurs frequently, or document stops midway).
■ Temporary error Indication ■ Device alarm (Permanent error) Meaning Indication Meaning U1 A paper feed error occurred. E2 A trouble in the optical system (front). U2 A double feed error occurred. E3 A trouble in the optical system (back). U6 The print cartridge is not set. E4 The motor fuse has blown out. E6 A trouble in the operator panel. The following shows the procedure for releasing of each temporary error. E7 A trouble occurred in the EEPROM.
Appendix2 DAILY CARE WARNING The glass of the inside of the ADF becomes hot during operation. When you clean the inside of the scanner, turn off the power and unplug the AC adapter from the outlet and wait for at least three minutes. Do not turn off the scanner when you clean the Feed rollers or Eject rollers. ■ Locations and Cycle for Cleaning Part to clean Pad ASSY Standard Cleaning Cycle Clean these parts after every 5,000 scans.
Appendix3 REPLACING CONSUMABLES WARNING The glass of the inside of the ADF becomes hot during operation. When you clean the inside of the scanner, turn off the power and unplug the AC adapter from the outlet and wait for at least three minutes. Folowing illustration shows the locations of the parts to be replaced. Refer to "Chapter 4 Replacing Consumables" fi-4530C Operator’s Guide on the Setup CD-ROM. ■ Replacing the Pad ASSY Do not turn off the scanner when you clean the Feed rollers or Eject rollers.
This Manual uses recycled paper.