Computer Products of America Image Scanner Operator's Guide fi-4990C
Table Of Contents
- Cover
- Inner Cover
- Revision Record
- Addresses
- IMPORTANT NOTE TO USERS
- Preface
- Conventions
- CONTENTS
- Chapter Index
- CHAPTER 1 COMPONENTS
- CHAPTER 2 INSTALLATION AND CONNECTIONS
- CHAPTER 3 OPERATING INSTRUCTION
- CHAPTER 4 DOCUMENT SPECIFICATION
- CHAPTER 5 SPECIFICATIONS
- CHAPTER 6 SETUP, BROWSE, AND TEST MODES
- Setup, Browse, and Test Modes
- Activating the Setup or Browse Mode
- Contents of the Setup or Browse Mode
- Transition of screens in setup mode
- Paper length check
- Doublefeed check
- Paper thickness setup
- Skew check
- IPC-3 mode
- Hopper height
- Paper separation level
- Drop-out color
- Background changeover
- Consumable counter
- Consumable counter reset
- Consumable alarm mode
- Buzzer
- Buzzer volume
- LCD contrast
- Picking speed
- TP_IF baud rate
- SCSI ID
- Product ID
- Pre-pick
- Pick start time
- Manual feed timeout
- Paper pick retry
- Paper feed retry
- Function key
- Setup mode lock
- Language
- White follower mode
- Interface board slot
- SCSI bus width setting
- Activating the Test Mode
- Contents of the Test Mode
- GLOSSARY OF TERMS
- INDEX
- Declaration of Conformity
- Back Cover

5-3
Consumables
The following table lists consumables used for the scanner. Be sure to keep some consumables in stock.
Customer is responsible to change these items periodically. The consumable counter can be used to check
the number of scanned documents. (See page 3-4, 6-22.)
Name Specification Service life and remarks
Lamp CA04315-0430 1000 hours or more. Two lamps used per scanner.
Pad CA04315-G730 300,000 sheets or one year.
Pick roller unit CA04315-F711 300,000 sheets or one year.
Brake roller CA04315-F705 300,000 sheets or one year.
Print head CA01023-0701 20,000 sheets (10 characters/sheet).
Black ink cartridge for endorser.
NOTE
• These service lives (replacement cycles) may be shortened depending on paper types of
documents scanned or wrong cleaning of the scanner.
• When carbon-less paper is used, the replacement cycle is shortened. So, these parts must be
replaced earlier than above.
• Adjust Consumable counter if shortened consumable life is expected. This will ensure
consumables are replaced when needed. (page 6-22)
11C5.P65 01.2.17, 5:45 PM3