Computer Products of America Image Scanner Operator's Guide fi-4990C
Table Of Contents
- Cover
- Inner Cover
- Revision Record
- Addresses
- IMPORTANT NOTE TO USERS
- Preface
- Conventions
- CONTENTS
- Chapter Index
- CHAPTER 1 COMPONENTS
- CHAPTER 2 INSTALLATION AND CONNECTIONS
- CHAPTER 3 OPERATING INSTRUCTION
- CHAPTER 4 DOCUMENT SPECIFICATION
- CHAPTER 5 SPECIFICATIONS
- CHAPTER 6 SETUP, BROWSE, AND TEST MODES
- Setup, Browse, and Test Modes
- Activating the Setup or Browse Mode
- Contents of the Setup or Browse Mode
- Transition of screens in setup mode
- Paper length check
- Doublefeed check
- Paper thickness setup
- Skew check
- IPC-3 mode
- Hopper height
- Paper separation level
- Drop-out color
- Background changeover
- Consumable counter
- Consumable counter reset
- Consumable alarm mode
- Buzzer
- Buzzer volume
- LCD contrast
- Picking speed
- TP_IF baud rate
- SCSI ID
- Product ID
- Pre-pick
- Pick start time
- Manual feed timeout
- Paper pick retry
- Paper feed retry
- Function key
- Setup mode lock
- Language
- White follower mode
- Interface board slot
- SCSI bus width setting
- Activating the Test Mode
- Contents of the Test Mode
- GLOSSARY OF TERMS
- INDEX
- Declaration of Conformity
- Back Cover

6-24
Consumable counter reset
This function is to be used when the consumable parts are replaced before the accumulated value of
the consumable conter reaches to the setting value.
NOTE
You cannot use this function when the setup mode is brought by pressing “MENU” in the Ready
status.
Remarks
YES: Reset the accumulated
consumable counter value.
NO: cancel the resetting of
consumable counter value.
LCD display
Consumable Counter
Reset
Options
YES, NO (Default)
The following is an example of operation when you change the setting.
<<SETUP MODE>>
<<SETUP MODE>>
Consumable Counter Reset
1. <<SETUP MODE>> initial screen, press
ENTER
.
The <<SETUP MODE>> menu screen (Paper
Length Check) appears.
2. Press repeatedly until “Consumable
Counter Reset” appears in the lower line of
the menu screen.
3. Press
ENTER
.
The current option list screen appears with
NO blinking. (blinking indicates “changeable”).
4. Press or .
The displayed option changes (YES blinks).
Reest Counter Value
NO 00250000
Reest Counter Value
YES 00250000
<<SETUP MODE>>
Paper Length Check
14C6.P65 01.2.17, 5:46 PM24