P3PC-E967-02EN fi-5650C Image Scanner Getting Started
■ Introduction Thank you for purchasing the fi-5650C duplex color scanner product. This document describes how to handle fi-5650C Duplex Color and basic operation methods. Before you start using the fi-5650C duplex color scanner, be sure to thoroughly read this manual to ensure correct use. The “Operator’s Guide” is guide is stored on the User manual CD-ROM. The guide provides useful and detailed information on operation, daily care, replacement of consumables and trouble shooting, etc.
Bescheinigung des Herstellers / Importeurs Für den fi-5650C wird folgendes bescheinigt: • In Übereinsstimmung mit den Bestimmun- gen der EN45014(CE) funkentstört • Maschinenlärminformationsverordnung 3. GPSGV: Der höchste Schalldruckpegel beträgt 70 dB (A) oder weniger, gemäß EN ISO 7779. International ENERGY STAR® Program As an ENERGY STAR® Partner, PFU LIMITED has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.
porated in the United States and/or other countries. ISIS and QuickScan are trademarks or registered trademarks of EMC Corporation in the United States. Corporations in the United States. Other product names are the trademarks or registered trademarks of the respective companies. How Trademarks Are Indicated In This Manual References to operating systems (OS) are indicated as follows: Windows 95: Microsoft® Windows® 95 operating system. Windows 98: Microsoft® Windows® 98 operating system.
■ Preface Symbols Used In This Manual Safety Precautions This manual uses the following symbols in explanations in addition to warning indications. This manual describes important details for ensuring the safe and correct use of this product. Thoroughly read this manual before you start to use this product. In particular, be sure to read and fully understand the Safety Precautions described in this manual before you use this product.
Warning Labels This product carries the following label warning label. The glass surface inside the ADF becomes hot during the operation. Be careful not to touch the glass surface inside the ADF. ATTENTION Do NOT remove from the scanner, stain or scratch the warning labels. ■ Safety Precautions WARNING The following describes important warnings described in this manual. Do not touch the AC cable with wet hands. Do not touch the power plug with wet hands. Doing so might cause electric shock.
Wipe any dust from the power plug. Wipe off any dust from metal parts on the power plug or metal fittings with a soft, dry cloth. Accumulated dust might cause fire or electric shock. Do not install in locations subject to oil smoke, steam, humidity, and dust. Do not install the scanner in locations subject to oil smoke, steam, humidity, and dust. Doing so might cause a fire or electric shock. Do not use the scanner if you smell strange odor.
Do not block the ventilation ports. Do not block the ventilation ports. Blocking the ventilation ports generates heat inside of scanner, which may results in fire or scanner failure. Do not use aerosol sprays near the scanner. Do not use aerosol sprays to clean the scanner. Aerosol sprays cause dirt and dust to enter the scanner, resulting scanner failure and malfunction. Do not place heavy objects or climb on top of the scanner.
viii
Contents Chapter1 Chapter 2 Appendix ■ Introduction................................................................. i ■ Regulatory Information ............................................... i ■ Note, Liability ............................................................ iii ■ Preface ..................................................................... iv ■ Safety Precautions .................................................... v PREPARING THE SCANNER..... 1-1 1.
x
Chapter1 PREPARING THE SCANNER 1.1 Checking the contents of scanner package 1-2 1.2 Names and functions of parts .................... 1-2 1.3 Functions of the operator panel ..................
1.1 Checking the contents of scanner package When you unpack the scanner package, make sure that the package contains all the parts on the list included in the package. If any parts are missing or defective, contact your sales representative. Handle the scanner and accessories with care. 1.2 Names and functions of parts TABLE 1. No. Name Function 5 Side guide button Used for adjusting the side guides. 6 ADF Button Press this button to open the ADF.
TABLE 2. TABLE 3. No. Name Function No. Name 12 USB Interface Connector Used for connecting a USB interface cable from a PC. 19 Sheet Guide 20 Brake Roller Power Inlet Used for connecting a AC cable from the power outlet. 21 Pick Arm 22 Plastic Rollers Used for turning ON/ OFF the scanner. 23 Feed Rollers 24 Ultra Sonic Sensors (Multi feed detection) 25 Glass 13 14 Power Switch 15 Third Party Slot (Optional Slot) The slot for an option board and extended memory boards.
TABLE 4. Indications on the Function No. display Name Function (1)LED Lights when the scanner is turned ON. (2) Function No. display Indicates the function No. and error status. Buttons (3) Function Changes the Function activated by the Send to button .
Chapter 2 INSTALLATION OF THE SCANNER 2.1 Installing the scanner ............................................ 2-2 2.2 Connecting the scanner to your PC....................... 2-3 2.3 Installing the Scanner Application .........................
2.1 Installing the scanner 1. Place the scanner at its installation site. This scanner can be placed with the ADF paper chute facing either right or left side of the installing location. For details on the scanner’s dimensions and required installation space, refer to "10 SCANNER SPECIFICATION" in the "fi5650C Operator's guide". 2. 4. Connecting the AC cable. Open the cable cover located below the ADF paper chute and insert the AC cable into the power inlet. Cable cover Setting the ADF Paper Chute.
with either the USB or the SCSI interface cable. ATTENTION Do not connect both the USB interface cable and the SCSI cable at the same time. It is not possible to use the USB interface with Windows 95 and/or WindowsNT 4.0. Connecting the USB Cable 1. Please connect a USB cable to the Scanner. Open the cable cover located below the ADF paper chute and connect the USB interface cable to the USB interface connector.
The SCSI has to fit to a 50 Pin half pitch connector and the SCSI card connector of your PC. • SCSI card Use the recommended SCSI card noted on the following website: 1. Turn the scanner OFF. 2. Set the SCSI ID. Open the cable cover located below the ADF paper chute and set the device address by using the SCSI ID switch. http://imagescanner.fujitsu.com/ 0 7 456 8 1 1.
Application: ScandAll 21 (for TWAIN) QuickScan Pro (for ISIS) 2.3.1 For Fujitsu Twain 32 Scanner Driver Preparation Before installing the application, please confirm the following items: • Keep the Setup CD-ROM at hand. • Confirm if the scanner is connected to your PC correctly. • If an older version of the FUJITSU TWAIN 32 Driver has already been installed, please uninstall it before installing the new one. • There are two types of FUJITSU TWAIN 32 Drivers.
4. Click [INSTALL PRODUCTS]. 7. Select a language used for installation on [Choose Setup Language] window and click [OK]. 8. Install the application following the instructions on the window. 5. Click [TWAIN Driver] on the window below. 9. When the [InstallShield Wizard Complete] window appears, click [Finish]. 6. Error Recovery Guide Installation window appears. 10. Your computer is restarted and the scanner will be detected.
2. When any alarm is displayed on [Hardware Installation] window, click the [Continue Anyway] button. 3. Click the [Finish] button. 3. Click [ScandAll 21]. 4. Select an appropriate language from the menu and click [OK]. 5. Install the application following the instructions on the screen. 6. When [InstallShield Wizard Complete] screen is displayed, click [Finish]. Now the installation of the scanner driver is completed.
Confirming the installation 5. Select [To View] from the [scan] menu. 6. Set the scanning resolution, document size etc. on the [TWAIN driver] window (for setting details of the scanning) and click the [Scan] button. Please confirm if FUJITSU TWAIN32 Scanner Driver and ScandAll 21 were installed correctly with the following procedure. 1. Set your documents into the ADF Paper Chute. For the loading of documents, please refer to 2.3 "Scanning documents" of the "fi5650C Operator's Guide". 2.
2.3.2 For Fujitsu ISIS Scanner Driver 3. Insert the Setup CD-ROM into the CD Drive. The will be displayed. Preparation Please confirm the following items before installing the ISIS driver: • Setup CD-ROM • Confirm if the scanner is connected correctly to your PC. HINT ATTENTION This screen may not be displayed when the, “Autoplay” setting of your PC is turned off. In this case, please run "Install.exe" on the CD-ROM directly from explorer or "My Computer". 4.
ATTENTION 7. When you select [Yes] for installing Error Recovery Guide, [Choose Setup Language] window appears. Select a language and follow the instructions on the window. Error Recovery Guide will automatically start on finishing its installation. Please wait until the installation of ISIS driver automatically starts. Select an appropriate language used for the installation from the window and click [OK]. 2.
3. Click the [QuickScan PRO (trial)] button in the following screen. 6. Install the application following the instructions on the window. Confirming the installation Please confirm if FUJITSU ISIS scanner driver and ScandAll 21 were installed correctly with the following procedure 1. 4. Load the documents on the scanner. For loading documents, please refer to Chapter 2 "BASIC SCANNER OPERATIONS" of the "fi-5650C Operator's Guide". Install the application following the instructions on the window. 2.
7. Select [Preview Scan] from the [Scan] menu to start the scanning- 2. Click [INSTALL PRODUCTS]. 3. Click [Error Recovery Guide] in the following screen. 4. Select a language to use for the installation in the window and click [OK]. 5. Install the application following the instructions on the window. 6. When the [InstallShield Wizard Complete] screen is displayed, click [Finish].
Installing the Image processing software option (trial version) 2. Click the [Install] button when the following screen is displayed. Then click the [Install Acrobat 6.0 Standard] button. 3. Click the [Next] button when the following screen is displayed. For the installation of the image processing software option (trial version), please refer to the "Image Processing Software Option User's Guide"which is stored at [User’s Guide] [Image processing software option] in the Setup CD-ROM.
2-14
Appendix Appendix 1 Troubleshooting .......................... AP-2 Appendix 2 Daily Care ................................... AP-7 Appendix 3 Replacing Consumables ............
Appendix 1 Troubleshooting Before you ask for repair service, check the following items. If the problem persists even after implementing remedies below, contact the dealer where your purchased the or an authorized FUJITSU service provider. Troubleshooting checklist TABLE 1. Symptom Check this Item Remedy Scanner cannot be tuned ON. Did you push the power switch? Push the power switch. Is AC cable connected correctly? Correctly connect the AC cable.
TABLE 1. Symptom Check this Item Remedy The scanned image shifts or is distorted. Is the ADF cover pressed down or heavy object placed on the ADF during scanning? Do not press down the ADF nor place heavy objects on the ADF during scanning. Is something causing the scanner to vibrate during scanning? Do not allow anything to cause the scanner to vibrate while scanning. Are the documents loaded correctly? Load the documents correctly. Quality of scanned pictures or photos is not satisfactory.
TABLE 1. Symptom Check this Item Remedy Documents are not fed into the ADF (pickup error occurs frequently or the document stops midway). Do the documents qualify the "Document Quality" and "Doublefeed Detection Condition" in "8 DOCUMENT SPECIFICATON FOR THE ADF" of the "fi-5650C Operator's Guide"? Use the documents that qualify the "Document Quality" and "Double-feed Detection Condition" in "8 DOCUMENT SPECIFICATON FOR THE ADF" of the "fi-5650C Operator's Guide".
TABLE 1. Symptom Check this Item Remedy There is a shadow on the leading edge of the scanned images. Did you cleaned all of the rollers? Clean all the rollers. For details, refer to "4 DAILY CARE" of the "fi-5650C Operator's Guide" Do the documents qualify the "Document Quality" in "8 DOCUMENT SPECIFICATON FOR THE ADF" of the "fi-5650C Operator's Guide"? Use documents that satisfy the requirements.
TABLE 3. Temporary Error Indication Meaning E2 Optical error (ADF front). E3 Optical error (ADF back). E4 Motor fuse malfunction. E5 Lamp fuse malfunction. E6 Operator panel malfunction. E7 EEPROM malfunction. E8 SCSI interface fuse malfunction. E9 Image memory malfunction. EA Imprinter malfunction. (*) The following shows the procedure for resolving of each temporary error. Ec Memory malfunction. Ed Malfunction at SCSI interface controller.
Appendix 2 Daily Care The glass of the inside of the ADF becomes hot during operation. CAUTION Before you clean the inside of the scanner, turn OFF the power and unplug the AC cable from the outlet and wait (at least three minutes) until it gets cold. Do not turn OFF the scanner when you clean the Feed rollers. Cleaning Materials TABLE 4. Cleaning Materials Part No. Remarks Cleaner F1 CA99501-0013 1 bottle. Moisten a cloth with this fluid and wipe the respective areas.
Locations and Cycle for Cleaning TABLE 5. Names of parts ADF Chute Roller Pick Arm Pick Roller Set Brake Roller Feed Rollers Plastic Rollers Sheet Guide Glass Ultrasonic Sensor Standard Cleaning Cycle using Cleaner F1 Standard Cleaning Cycle using Cleaning Paper with Cleaner F1 Standard Cleaning Cycle using Cleaner F2 Clean these parts after every 10,000 scans. Clean these parts after every 10,000 scans. When stains are persistent.
Appendix 3 Replacing Consumables of the used paper and how frequently the scanner is used and cleaned. ATTENTION CAUTION Use only the specified consumables. The glass of the inside of the ADF becomes hot during operation. When you clean the inside of the scanner, turn OFF the power and unplug the AC cable from the outlet and wait for at least three minutes. The following pictures shows the locations of the parts to be replaced.
fi-5650C Image Scanner Getting Started P3PC-E967-02EN Date of issuance: June, 2006 Issuance responsibility: PFU LIMITED z Copying of the contents of this manual in whole or in part and copying of the scanner application is forbidden under the copyright law. z The contents of this manual are subject to change without notice.