Datasheet
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
17
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
● Part explanation
• LAN (RMT) port, LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables. LAN (RMT) port is not used in the
EMEA&I region.
A single controller has one LAN (RMT) port and one LAN (MNT) port.
• FC port (0 (left), 1 (right))
These are the Dual LC connectors to connect FC cables.
• PWC port
This port is not used.
• DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a miniSAS cable.
• LEDs
The states of LEDs are listed below.
Table 1.4 Status and meanings of each LED (FC model controller)
LED name LED status Controller status
SCU STATUS
(green)
The SCU is in normal status.
(blinks green)
SCU is charging.
IDENTIFY
(blinks blue)
As ordered via ETERNUS Web GUI, the installation
location of the controller enclosure is identified.
(off)
DI (OUT) LINKUP
(green)
The link between the DI (OUT) port and the destination
has been established.
FC LINKUP/
FAULT
(green)
The link between the FC port (host interface port) and
the destination has been established.
(orange)
The FC port (host interface port) is in error status.
UNIT READY/
FAULT
(green)
The controller is in normal status.
(orange)
• The controller is performing the initial setup after the
power is turned on.
• The controller is in error status.
MASTER
(green)
The controller is set as a Master CM.
ACT
(green)
The controller is sending or receiving data via the LAN
port (for operation management).
LINK
(green)
The link between the LAN port (for operation
management) and the destination has been
established.










