Datasheet

Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
20
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
SAS model
Figure 1.14 Controller (SAS model)
Part explanation
LAN (RMT) port, LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables. LAN (RMT) port is not used in the
EMEA&I region.
A single controller has one LAN (RMT) port and one LAN (MNT) port.
SAS port (0 (left), 1 (right))
These are the miniSAS (SFF8088) connectors to connect miniSAS cables.
PWC port
This port is not used.
DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a miniSAS cable.
LEDs
The states of LEDs are listed below.
Table 1.6 Status and meanings of each LED (SAS model controller)
LED name LED status Controller status
SCU STATUS
(green)
The SCU is in normal status.
(blinks green)
SCU is charging.
IDENTIFY
(blinks blue)
As ordered via ETERNUS Web GUI, the installation
location of the controller enclosure is identified.
(off)
DI (OUT) LINKUP
(green)
The link between the DI (OUT) port and the destination
has been established.
SAS port (0 (Left), 1 (Right))
SAS (HOST) LINKUP/FAULT LED
DI (OUT) port
PWC port
ACT LED
LINK LED
MASTER LED
UNIT READY/FAULT LED
LAN (RMT) port
DI (OUT) LINKUP LED
SCU STATUS LED
IDENTIFY LED
LAN (MNT) port