Remote Monitoring Station Instruction Manual (detailed version) How to Use This Manual Pages 3 and 4 of this document contain the same information as the instruction manual “Usage Precautions” sheet packaged with Remote Monitoring Station (“the product”). Pages in this section are not numbered. If you require a printed copy of the instruction manual, please print pages 3 and 4 of this document on B4 or larger sized paper.
Content ■ Alarm Indication ................................................ 3 ■ To users of this product ........................................ 3 ■ Confirm included items prior to use ............................. 3 ■ Ports and controls – main unit - ................................ 3 ■ Power ON/OFF .................................................. 3 ■ Installation of Remote Monitoring Station ....................... 3 ■ Safety Notes .................................................... 4 ■ Disposal ...
Remote Monitoring Station - Precautions for use To users of this product Please contact the source this product was obtained from if you have any questions about using this product or if you need help resolving any concerns. More Information can be found on the Internet at: http://www.fmworld.net/biz/uware/support/ ■ Alarm Indication In this manual, various pictures are used to indicate alarm. These are signs to prevent harms and damages that might be added to you and other people.
. Peel the film from the Adsorption tape (or paper from the non-cut side of the Double-sided tape), attach it firmly to the adhesion surface, and then install the Remote Monitoring Station. Note the following during installation. * * * * Install on a flat surface with no irregularities. Remove any dirt, water, or oil from the installation location prior to installation. Do not attach double-sided tape to locations with weak surfaces such as wallpaper.
■ FCC CAUTION This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
■ Detailed information □ Function List In order to use this function, “UBIQUITOUSWARE Sensor Algorithm” (sold separately) is required. ・Product function Function Specification Application Example Safety confirmation Trespassing prevention Safety confirmation Health monitoring Sound detection Detects conversation and speech of the person. Snoring detection Detects snore frequency/interval. Disturbance detection of respiration Detects the length of the long silence interval between snoring.
・Cooperation function with the vital sensing band Function Bluetooth out-of-range notification Transfer function of the sensor data of the vital sensing band Firmware update function of the vital sensing band Specification Application Example Detects when Vital Sensing Band's Bluetooth connection drops, and can notify the administrator that the user has moved away from the Out-of-range notification Remote Monitoring Station.
□ Sound playback function ・Customizing the audio file The audio file played over the Remote Monitoring Station and each function sound can be customized over the network. List of sounds that can be configured No. Type Length Usage Playback Stop Volume Priority Default announcement message "There has been an earthquake. Please act calmly. Stay safe and extinguish the source of the fire. Please check the TV or radio for information and stay calm.
No. Type Length Usage Playback Confirmation sound played when the Call Cancel Button is pressed Chime sound played prior to playing an information announcements/thermal environment level announcement When the Call Cancel Button is pressed Announcement 1-5 / Prior to thermal environment level announcement When a thermal environment level of 4 or 5 is detected * After playing the chime sound, an alert announcement must be made.
* One with a small figure is reproduced by priority. * It reproduces in the winning when the same priority reproduction demands are generated. Sound data that can be played on this product is PCM format. - sampling rate:16000Hz - bit sample:16 bit - number of channels:1ch(monaural) - volume level:The largest level where a waveform clip is not generated is recommended. Please edit the sound source by using the sound edit software to become the above-mentioned condition.
□ Limitations of each sensing Mic ・May detect sounds from sources other than people. For example, sounds from dogs or cats may be detected as voices. ・If used with a window left open, sounds from outside may make it difficult to detect human voices, or the device may react to human voices from outside. ・Detection performance - It detects it when there is 5 dB or more sound pressure difference between a surrounding noise and the sound to be detected.
□ Main unit operation (Gateway Software Configuration Tool) Operation items Setting of Remote Monitoring Station Overview Configure the Remote Monitoring Station. Remarks Please refer to the appendix in the User's Guide (Gateway/Device Settings Version) for settings. Remote Monitoring Station diagnosis └ WLAN connection status └ Server connection status └ Pyroelectric sensor status Confirm operation of the Remote Monitoring Station.
□ Main unit operation (Device Management Tool) Operation items Device / Gateway / Remote Monitoring Station List Overview Display the list of Device / Gateway / Remote Monitoring Station. On clicking a device ID or a gateway ID or a station ID in the Checking Contents of Device / Gateway / Remote Monitoring "Device/Gateway/Remote Monitoring Station List," you can check Station the data contents that are set for that ID.
□ Product operation ( Button ) ・Normal button operation Status Emergency Call Button Short push During/Under normal operation During emergency report / During consulting report / During announcement During VoIP call During trespassing prevention mode During camera photographin g During firmware update Out-of-servi ce Configuring product from smartphone over a Bluetooth connection During Bluetooth setting Emerge ncy call Push and hold - Consulting Call Button Short push VoIP incomi ng Push and hold
・Plural button operation WLAN Connect & BLE Pairing Button Power-on with pushing both buttons at the same time WLAN Connect & BLE Pairing Button Status Short push Push and hold Short push Push and hold During/Under normal operation - Reset to factory default - Bluetooth pairing with the Vital Sensing Unit During emergency report / During consulting report / During announcement - - - - During VoIP call - - - - - - - - - - - - - - - - - - - - - - - Bluetooth pairing wit
□ LED list LED Status of main unit Status of LED Calling Status LED (Green and Red) Emergency announcement Green flashing Dangerous Heat Disorder announcement Talking Green lights Equipment abnormality occurs in Red flashing During a firmware update Green fast flashing Power LED (Green) Power ON Lighting Power OFF Turning lights off Camera LED (Green) Camera use Lighting⇒20 seconds after off Camera unused Turning lights off WLAN setting in Green flashing WLAN setup complete Green lights
Remote Monitoring Station Instruction Manual (detailed version) Published by FUJITSU LIMITED Information on the product description meets the design specifications of Fujitsu and is provided for comparison purposes. Several factors may cause the actual results to differ. Technical data is subject to change without prior notification. Fujitsu rejects any responsibility with regard to technical or editorial mistakes or omissions.