Server User Manual

Note -
Check that XSCF DUAL control cable is correctly connected and secure.
Note - After connecting the XSCF DUAL control cable, use the hook-and-loop fastener to
bundle the cables together and fasten them to rear cable support.
2.
Remove the XSCF DUAL control cables from the other chassis.
Pull out the XSCF DUAL control cable while pushing the lock release buttons on
the both sides of the cable.
27.5 Installing an XSCF DUAL Control
Cable
This section describes the procedure for installing an XSCF DUAL control cable.
1.
Attach the supplied connection destination label to the replacement XSCF
DUAL control cable.
For the new XSCF DUAL control cable, use the same type of label as the one on
the cable requiring maintenance and write the same port number on it.
2.
Connect the XSCF DUAL control cable to SPARC M10-4S or the crossbar box.
27.6 Restoring the System
This section describes the procedure for restoring the system after installing the XSCF
DUAL control cables. The restoration procedure differs depending on the maintenance
type as follows:
Active/Hot maintenance
Active/Cold maintenance
Inactive/Hot maintenance
Inactive/Cold maintenance
System-stopped maintenance
27.6.1 Active/Hot maintenance
1.
Return to the operation of the XSCF firmware replacefru command to confirm
that the XSCF DUAL control cable has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2.
Execute the show status command to confirm that the FRU is operating
Chapter 27 Maintaining the XSCF DUAL Control Cables 421