Server User Manual

XSCF>
showstatus
XSCF>
showhardconf
SPARC M10-4S;
+ Serial:2081235006; Operator_Panel_Switch:Locked;
+ System_Power:Off; System_Phase:Cabinet Power Off;
Partition#0 PPAR_Status:Powered Off;
BB#00 Status:Normal; Role:Master; Ver:2047h; Serial:2081235006;
+ FRU-Part-Number:CA07361-D202 A1 ;
+ Power_Supply_System: ;
+ Memory_Size:160 GB;
------------------------
Ommitted
------------------------
BB#01 Status:Normal; Role:Standby; Ver:2047h; Serial:2081228004;
+ FRU-Part-Number:CA07361-D202 A0 ;
+ Power_Supply_System: ;
+ Memory_Size:128 GB;
------------------------
Ommitted
-----------------------
XSCF>
switchscf -t Standby
6.3 Powering On the Physical Partition
Requiring Maintenance
This section describes the procedure for powering on a physical partition requiring
maintenance.
1.
Switch the mode switches of the master chassis and those chassis whose
XSCFs are in the standby state to Locked mode.
-
For a building block configuration (without crossbar box)
Switch the mode switches of BB-ID#00 and #01 to Locked mode.
-
For a building block configuration (with crossbar box)
Switch the mode switches of BB-ID#80 and #81 to Locked mode.
2.
LogintotheXSCFshell.
3.
Execute the show status command to confirm that there is no problem with
the FRU after the completion of maintenance.
If there is no problem, nothing is displayed.
4.
Execute the show hardconf command to check the hardware configuration
and the status of each component.
5.
If the state of the master chassis requiring maintenance has been switched to
the standby state before maintenance, execute the switchscf command to
switch the chassis to the master XSCF.
6.
Execute the pow eron command to power on the stopped physical partition.
Chapter 6 Understanding the Prepara tions for Restoring the System 73