User's Manual

5.2 Log Parameters
The accumulated power-on time (unit: minute) at processing the LOG SENSE
command is shown in the "Time Stamp" field.
The values reported to the "BMS Status" field are defined below.
Table 5.61 BMS status
Value Description
0h No medium scan
1h Background medium scan in progress
2h Pre-Scan in progress
3h Halt the Medium Scan due to fatal error
4h Halt the Medium Scan due to vendor specific pattern of errors
5h Halt the Medium Scan due to medium formatted without the P-List
6h Reserved
7h Halt the Medium Scan due to Irregular Temperature condition
8h Scan suspended until BMS Interval Timer
The execution time of the Medium Scan operation is shown in the "Number of
Scans Performed" field.
The progressing rate of the Medium Scan operation is shown in the "Medium Scan
Progress" field.
C141-C013 351