User manual

Configuring the Terminal Configuration the IBP Module
Intelligent Blade Panel Module
36
5.4 Configuring the Terminal
To configure the device, the station must be running terminal emulation software. Ensure that
switch module is correctly mounted and is connected to the chassis serial port. Ensure that the
terminal emulation software is set as follows: Connect PRIMERGY BX600 Blade Server serial
port to the IBP Module.
NOTE:
1. The default data rate is 9600. No other data rate is required for initial configuration.
2. Sets the data format to 9600 baudrate 9600,8 data bits, 1 stop bit, and no parity.
3. Sets Flow Control to none.
4. Under Properties, select VT100 for Emulation mode.
5. Select Terminal keys for Function, Arrow, and Ctrl keys. Ensure that the setting is for
Terminal keys (not Windows keys).
For accessing IBP module from terminal perform following steps:
1. Connect your terminal to the serial port of the Chassis.