PRIMERGY RX300 S7 System configurator and order-information guide April 2014 Contents Instructions Configuration diagram Configurator 0 System software I Basic unit II Processor III Memory IV Graphics V Accessible drives VI Hard disk drives VII PCI Controller VIII Communication/Network IX System Management Products (RemoteView) X Miscellaneous XI Country specific power cord Change report PRIMERGY Server
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 Instructions This document contains basic product and configuration information that will enable you to configure your system via PC-/System-Architect. Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Rack system. You can configure your individual PRIMERGY server in order to adjust your specific requirements.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 Configuration diagram PRIMERGY RX300 S7 System unit ( I ) with up to 6x 3.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 Configuration diagram PRIMERGY RX300 S7 System unit ( I ) with up to 4, 8, 12 or 16x 2.
PRIMERGY-Software Configurators and Release Lists PRIMERGY RX300 S7 Status 2014-03-31 Start PRIMERGY RX300 S7 SW Configurator 32 bit with OEM-Software for PRIMERGY Server without OEM-Software for PRIMERGY Server OEM- SW is bound to HW and is not allowed to be ordered separately.
PRIMERGY-Software Configurators and Release Lists PRIMERGY RX300 S7 Status 2014-03-31 Start PRIMERGY RX300 S7 SW Configurator 64 bit (EM64T / IA64) with OEM-Software for PRIMERGY Server without OEM-Software for PRIMERGY Server OEM- SW is bound to HW and is not allowed to be ordered separately.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 Start PRIMERGY RX300 S7 I Section Basic unit System unit consisting of: * 2U Housing without power supply modules * Basic units with: - 2 Hot-Plug Power Supply Bays - 5 Fans (full redundancy) * SAS Backplane for 6x 3.5" HD or SAS Backplanes for 4, 8, 12 or 16x 2.5" HD with cable connection to on-board or modular RAID Controller * Drives/Bays - 6 bays 1" for hot plug 3.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 A Cables included in basic unit Connections Cable PRIMERGY RX300 S7 1. SATA DVD 2. SAS cables to HDDs 3. 1x cable for SAS signaling SAS SATA Note: Rack Mounting kit and Power Cord for RX300S7 is not included in the basic unit and has to be configured separately Rack version for 19'' racks with No PSU included in Base Unit Basic unit with 2.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 B PRIMECENTER Rack S26361-F2735-E145 RMK-F1_DI_CMA_QRL S26361-F2735-E175 Rack Mount Kit F1-C S7 LV S26361-F2735-E111 Further information for No Rackmount-Kit option rack mounting is available best choice for PrimeCenter racks best choice for 3rd party racks Only for loose deliveries within the consisting of consisting of No mounting in racks possible Corporate Partner Portal vario carrier 714-785mm vario car
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 C II Section Processor There are 2 processor sockets available.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 D IV Section Graphics Graphics Controller integrated in iRMC S3 (integrated Remote Management Controller): 1600x1200x16bpp 60Hz, 1280x1024x16bpp 60Hz, 1024x768x32bpp 75Hz, 800x600x32bpp 85Hz, 640x480x32bpp 85Hz (1280x1024x24bpp 60Hz only possible if local monitor or remote video redirection is off) S26361-F2571-E26 Optional Front-VGA for Onboard Controller only consists of internal cable and front VGA connector max.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 E III Section Memory - There are 12 memory slots per CPU for max. 384GB LRDIMM (12x 32GB 4R) 192GB RDIMM (12x 16GB 2R) 32GB UDIMM (8x 4GB) => max.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 F S26361-F3694-E10 Independent Mode Independent Channel Mode allows all channels to be populated in any order. No specific Memory RAS features are defined Requires min 1 memory Module per CPU S26361-F3694-E1 Rank Sparing Mode Installation BIOS Setup factory preinstalled to this mode. One Rank is spare of other ranks on the same channel. Spare Rank is not shown in System Memory.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 Memory Configuration PRIMERGY RX300 S7 Each CPU offers 12 Slots for DDR3 Memory Modules organised in 3 Banks and 4 Channels. If you need more than 12 Slots you have to configure the 2nd CPU. Depending on the amount of memory configured you can decide between 4 basic modes of operation (see explanation below).
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 Channel C Channel D Channel E Channel F Channel G Channel H Bank I Data (black sockets) Bank II Data (blue sockets) Bank III Data (green sockets) Channel B Channel A 1.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 4.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 G Va Section Possible configuration options for basic units Config 1: 6x or 4x 3.5” HDD + 3.5" DDS/RDX drive Is fixed due to selection of basic unit with: 6x 3,5" HDD bays fixed S26361-K1373-V101 Basic unit S26361-K1373-V401 with expandable Config 2: 4x 2.5” HDD S26361-F1373-E420 Available Upgrade kits for this configuration option: Upgrade kit to 8x 2.5" HDD S26361-F1373-L424 Upgrade kit to 12x 2.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 H Vb Section Accessible drives Setup RX300 S7 by ServerStart is supported with following configurations: no DVD, no CD: remote installation only ( PXE service & DHCP server required) built in CD/DVD or USB CD/DVD disk drive: UNC Network share reachable or USB Floppy connected USB Floppy, no CD/DVD: USB CD/DVD connected If installation is done locally, make sure you have external FDD available for driver installation.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 H1 USB 3.0 adapter & RDX S26361-F3749-E201 USB3.0 PCIe x1 adapter card lp Sunrich U-720 The adapter is also available as optional (loose) delivery with FH and LP bracket included S26361-F3749-L501 PCIe x1 1 port intern, 1 port extern USB 3.0 A jacks max. 1x per system Only for basic unit V4xx Only for basic unit V1xx S26361-F3750-E5 RDX Drive USB3.0 3.5" internal 100MB/s, USB 3.0 Connector: USB 3.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 H2 SAS Controller for internal Backup Drives S26361-F3674-E1 For internal SAS Backup drives Onboard 4 port SAS Controller an additional 4-port SAS controller has to be configured LSI Patsburg B RAID 0, 1 & 10 no controller cache SAS 1.0 (3Gb/sec) Only for basic unit V4xx 4 internal ports PCIe x4 no PCI slot required max.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 I VI Section Hard disks drives Modular Raid controller is connected to internal HDDs For basic units V1xx up to 6 SAS 3.5" hard disks can be configured also in mixed configuration. If the option "Tape drive" is configured only 4 bays for hard disks are available Mixed configurations with Eco SATA drives and SAS drives are not allowed 3.5" SAS drives and 3.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 J Solid State Disk, Mainstream Endurance* SSD SATA 6Gb/s 2.5" with hot plug/hot replace tray 100GB, Mainstream Performance S26361-F5303-E100 as soon as available 200GB, Mainstream Performance S26361-F5303-E200 as soon as available 400GB, Mainstream Performance S26361-F5303-E400 as soon as available 800GB, Mainstream Performance S26361-F5303-E800 as soon as available as soon as available SSD SAS 12Gb/s 2.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 K VII Section Modular Raid 0/1, Raid5 for SAS or SATA HD`s. On-board Controller for max. 4x 2.5" SATA or SAS HD`s On board SATA Controller with 3 Gb/sec and up to 4x 2.5" SATA HDDs (no additional controller required) For up to 4x 2.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 L SAS-/SCSI-/ Fibre-Channel Controller Low Profile SAS controller for external backup drives S26361-F3628-E201 SAS Controller 6Gb/s 8 port LP LSI SAS9200-8e LP PCIe 2.0 x4, ext: 8 port max. 3x per system Only a single vendor for FC and FCoE controller is supported. All controllers for the connection of external storage system are delivered without cables.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 M SAS RAID controller for JBOD subsystems S26361-F3593-E201 as long as available S26361-F3713-E201 as soon as available S26361-F3713-E203 8 port SAS RAID Controller RAID Ctrl SAS 6G 8port external RAID Ctrl SAS 6G 8port ext.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 N Section VIII Communication / Network 2x Gigabit (Dualport) Ethernet Contr. onboard Intel LAN I350 (Powerville) ext: 2x RJ 45 connector Modular On-Board LAN is a flexible extension of a cost-optimized Motherboard with basic 2x Gbit LAN on-board. 5 different Upgrade-Kits are offered, which occupies a dedicated PCIe slot and can be ordered once per system. If a modular LAN Controller is installed, max.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 N1 A) 1-Port Copper PCIe Adapter 1000TX S26361-F3516-E201 (Shelter Island) Gigabit Ethernet Controller 1000TX LP Eth Ctrl 1x1Gbit PCI-e Gigabit CT DT Cu LP Intel® Gigabit CT Desktop Adapter PCIe x1 ext: for RJ45-connector, Cat 5 max. 4x per system Loose delivery with: S26361-F3516-L201 B) 1-Port MMF PCIe Adapter 1000SX S26361-F3242-E201 (Sheepshead Bay) Gigabit Ethernet Contr.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 N2 If a 10Gb modular LAN Controller is installed, max. 1 additional of the following 10Gb LAN controller is possible! S26361-F3629-E202 E) 10GbE 2-Port SFP+ S26361-F3629-E202 (D2755) 10 Gigabit Ethernet Contr. dual port SFP+ Eth Ctrl 2x10Gbit PCIe x8 D2755 SFP+ Intel Niantic based dual port 10Gb NIC PCIe x8, Low Profile, Low Profile Bracket ext: 2x SFP+ cage max.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 O F) Fibre Channel over Ethernet S26361-F3592-E202 Loose Delivery: S26361-F3592-L202 10GBit/s CNA Emulex OCe10102 2 channel 10GBit/sec CNA SFP+ Cage PCIe x8, 170mm max.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 P Section IX System Management Products (RemoteView) iRMC S3 (integrated Remote Management Controller) onboard server management Controller with dedicated 10/100/1000 Service LAN-port and integrated graphics. Optional 10/100 Service LAN-port on front panel.
System configurator and order-information guide PRIMERGY RX300 S7 Status 2014-03-31 Change Report Date Order number Changes 2013-10-18 2013-10-16 2013-09-03 2013-05-28 2013-05-23 2013-05-16 2013-05-16 2013-05-16 2013-04-29 2013-03-25 2013-03-25 2013-03-25 2013-03-25 optional USB Comps S26361-F4610-E202 / -E204 no longer available added new 1Gb NICs from Intel RMK Cable management is not longer a must component 2013-03-21 2013-01-29 2013-01-17 2013-01-14 2013-01-08 2013-01-08 2012-12-13 2012-12-10 2