Datasheet

System configurator and order-information guide
FSC PRIMECENTER Rack Status 2007-09-26
External SCSI cabling between PRIMERGY Server (Controller) and PRIMERGY SX10
cable no. lengths
1.5m
1.8m
5.0 m
On-Board Controller
l
S26361-F2400-
L15
l ¡
l
S26361-F2400-
L15
l ¡
l
S26361-F2400-
L15
l ¡
l
S26361-F2400-
L15 L50
l ¡
¥
SNP:SY-F1947- L18-P L50-P
l ¡
¥
SNP:SY-F1947- L18-P L50-P
l ¡
¥
SNP:SY-F1947-
L18-P L50-P
l ¡
¥
SNP:SY-F1947-
L18-P L50-P
l ¡
l
S26361-F2400-
L15
l ¡
¥
SNP:SY-F1947- L18-P L50-P
l ¡
¥
SNP:SY-F1947- L18-P L50-P
l ¡
¥
SNP:SY-F1947- L18-P L50-P
l ¡
¥
SNP:SY-F1947- L18-P L50-P
l ¡
External SCSI Controller
l
S26361-F2400-
L15
l ¡
l
S26361-F2400-
L15 L50
l ¡
l
S26361-F2400-
L15 L50
l ¡
l
S26361-F2400-
L15 L50
l ¡
l
HD68(S) connector, 68-pin (screw connection)
¡
HD68(V) connector, 68-pin (interlocking)
¥
UHD68(S), also: VHDCI connector, 68-pin
More information on cabeling
For selecting the external cables refer also to the above overview about cabeling and pay atention to the backup devices in use.
no installation ex works:
External LVD SCSI cable 1,8m SNP:SY-F1947L18-P
External LVD SCSI cable 5,0m SNP:SY-F1947L50-P
installation ex works:
External LVD SCSI cable length customized SNP:SY-F1947E500-P
also for cascading
The cables -F1947 have a screwed VHDCI connector on one side ("very high density", also: UHD68(S), SPI-2)
and a screwed HD68(S) connector (also: MiniD68M) on the other side
no installation ex works:
External LVD SCSI cable 1,5m S26361-F2400-L15
External LVD SCSI cable 5,0m S26361-F2400-L50
installation ex works:
External LVD SCSI cable length customized S26361-F2400-E500
The cables -F2400 have a screwed HD68(S) connector on one side as well as on the other side (also: MiniD68M).
1 channel UW/F1630
Adaptec 29160N LP
Adaptec 29160N
PRIMERGY SX10
1 Kanal U160/F2737
Adaptec 2940 UW
PRIMERGY SX10
Adaptec 2940 U2W
1 channel U2W/F2068
PRIMERGY SX10
1 channel U160/F2399
PRIMERGY SX10
SCSI Extern TX200/TX300
PRIMERGY SX10
SCSI Extern H250/H450
SNP:SY-F2287E2-A
T26139-Y3849-E1
PRIMERGY SX10
SCSI Extern RX300/TX600
PRIMERGY SX10
SCSI Extern L200
T26139-Y3882-E1
T26139-Y3882-E101
PRIMERGY SX10
1 channel U2W
PRIMERGY SX10
SCSI Extern N200
LSI 53C1010
SYMBIOS 53C896
D1180
PRIMERGY SX10
1 channel UW
PRIMERGY Server PRIMERGY SX10
SCSI controller
1 Kanal U2W
SYMBIOS 53C895
1 channel UW/16Bit
PRIMERGY SX10
PRIMERGY SX10
D1305
SYMBIOS 53C875
PRIMERGY SX10
1 channel U2W
PRIMERGY SX10
PRIMERGY SX10
SCSI ExternT850
SNP:SY-F2287E5-P
SCSI Extern N400
S26361-F2287-E15
PRIMERGY SX10
Onboard U160
PRIMERGY SX10
SCSI Extern R450
FuJitsu Siemens Computers Enterprise Products - PRIMERGY Server 20 of 26