Datasheet

Data Sheet FUJITSU Server PRIMERGY TX150 S8 Mono-Socket Intel® Xeon® processor server
Page 4 / 10 www.fujitsu.com/fts
Onboard or integrated Controller
RAID controller additional RAID controller options are described under Components RAID controller
SATA Controller Intel® C602, 2 ports used for accessible drives
4 port for internal SATA HDDs with RAID 0, 1, 10 for Windows and Linux;
SATA controller type notes On board SATA controller supports RAID levels 0, 1, 10
Remote Management Controller Integrated Remote Management Controller (iRMC S3, 32 MB attached memory incl. graphics controller)
IPMI 2.0 compatible
Trusted Platform Module (TPM) Inneon / separate module; TCG V1.2 compliant (option)
Slots
PCI-Express 3.0 x4 (mech. x8) 2 x Full height 280 mm length
PCI-Express 3.0 x16 1 x Full height 280 mm length
PCI-Express 2.0 x1 (mech. x16) 1 x Full height 170 mm length
PCI-Express 2.0 x4 (mech. x8) 1 x Full height 230 mm length; preferred RAID slot
PCI-slots 1 x PCI 32/33 MHz, 1x long, 5V
Slot Notes in SAS conguration 1x PCI-Express occupied by modular RAID controller.
Drive bays
Storage drive bays 3.5-inch or 2.5-inch hot-plug SAS/SATA
Accessible drive bays 3 x 5.25/1.6-inch
Notes accessible drives all possible options described in relevant system congurator
Drive bays (Base unit specic)
Storage drive bays Max 8 (4 + 4) x 3.5-inch Max 16 (8 + 8) x 2.5-inch Max 16 (8+ 8) x 2.5-inch
Accessible drive bays 3 x 5.25/1.6-inch for 4 x 3.5-inch HDD/
SSD, or 2 x 3.5-inch HDD/SSD + 1 x
backup drive + local service display
1 x 5.25/0.5-inch for slimline ODD
3 x 5.25/1.6-inch for 8 x 2.5-inch
HDD/SSD + backup drive/ODD, or 8 x
2.5-inch HDD/SSD + slim ODD + local
service display
3 x 5.25/1.6-inch for 8 x 2.5-inch
HDD/SSD + backup drive/ODD, or 8 x
2.5-inch HDD/SSD + slim ODD + local
service display
General system information
Fan notes Redundant fan conguration is only available in combination with redundant PSU
Number of fans 3 4 3 4
Fan conguration 3+1 redundant 3+1 redundant
Fan notes non redundant / non hot-
plug
redundant / non hot-plug non redundant / non hot-
plug
redundant / non hot-plug
Operating panel
Operating buttons On/off switch
NMI button
Reset button
Status LEDs System status (orange / yellow)
Identication (blue)
Hard disks access (green)
Power (amber / green)
CPU status
Fan status
Hard disk error
Temperature
CSS (yellow)
Memory status
PSU status (green/ amber)
At system rear side:
System status (orange / yellow)
Identication (blue)
LAN connection (green)
LAN speed (green / yellow)
Service display Optional:
ServerView Local Service Display (LSD)