Datasheet

DATASHEET FUJITSU PRIMERGY TX200 S5 SERVER
Page 6 / 9 http://ts.fujitsu.com/Primergy
ELECTRICAL VALUES
Power supply conguration 1x standard, 1x redundant or 2x redundant
Max. output of single power supply 685 W
Standard power supply output 700 W
Hot-plug power supply output 800 W
Hot-plug power supply redundancy Yes
Rated voltage range 100 - 240 V
Rated frequency range 47 - 63 Hz
Rated current max. 9.5 - 4.0A
Rated current in basic conguration 1,3 0.6A
Active power (min. conguration) 111 W
Active power (max. conguration) 461 W
Apparent power (max. conguration) 490 VA
Heat emission 1659.6 kJ/h (1573.0 BTU/h)
Power Supply Notes In case of using an UPS we recommend to select a 1500VA/1000 W type as a minimum, because high power peaks might
be possible when switching over to battery!
ENERGY STAR
®
1.0 CERTIFIED CONFIGURATIONS
The following products use less energy and reduce greenhouse gas emissions by meeting the strict Energy Star guidelines.
LKN:T2005S0003IN (See web site below for conguration details)
http://ts.fujitsu.com/products/standard_servers/e_efcient.html
COMPLIANCE
Germany TÜV GS
Europe CE Class A *
USA/Canada CSAc/us
ULc/us
FCC Class A
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Japan VCCI Class A + JIS 61000-3-2
Australia/New Zealand C-Tick
Taiwan BSMI
Compliance notes There is general compliance with the safety requirements of all European countries and North America. National approvals
required in order to satisfy statutory regulations or for other reasons can be applied for on request.
* Warning:
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may
be required to take adequate measures.
Compliance link https://sp.ts.fujitsu.com/sites/certicates/default.aspx