Datasheet

Data Sheet Fujitsu PRIMERGY TX200 S7 Server
Page 7 / 10 www.fujitsu.com/fts
Server Management
Option ServerView Suite - Deploy
SV Deployment Manager (full version)
ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR) and Remote Storage
ServerView Suite - Dynamize
SV Virtual-IO Manager (VIOM)
SV Resource Orchestrator Virtual Edition (ROR VE)
SV Resource Orchestrator Cloud Edition (ROR CE)
ServerView Suite - Integrate
SV Integration pack for Fujitsu ManageNow® solution
Server Management notes Regarding Operating System dependencies and product details for ServerView Suite Software Products see dedicated
Product Data sheets.
Dimensions / Weight
Floor-stand (W x D x H) 177 (306 ) x 651 x 456 mm
Rack (W x D x H) 483 x 611 x 177 mm
Dimension notes Floorstand Width 177 mm without tilt protection (420 mm with tilt protection); depth measured includes handles on
redundant PSU. Rack depth includes handles of redundant PSU, excludes rack handles / front
Height Unit Rack 4 U
Weight 16 kg - 29 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Operating ambient temperature 10 - 35°C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 – Guideline for Data Center (installation locations)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) 22 dB(A) idle mode/ 22 dB(A) operation mode with low noise mode; 30 dB(A) idle mode/ 30 dB(A) operation mode
with SAS HDDs;36 dB(A) idle mode/ 36 dB(A) operation mode with HDD extension boxes;
Sound power (LWAd; 1B = 10dB) 4,0 B idle / 4,0 B operation mode with low noise mode; 4,8 idle mode/ 4,8 operation mode with SAS HDDs;5,4 B idle
mode/ 5,4 B operation mode with HDD extension boxes;
Noise notes / description Noise emissions and operation modes depend on system conguration.
Electrical values
Power supply conguration Base unit specic:
1x standard power supply or1x hot-plug power supply or 2x hot plug power supply for redundancy
Standard power supply output 800 W (90 % efciency, 80 PLUS gold)
Hot-plug power supply output 450 W or 800 W (94 % efciency, 80 PLUS platinum)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 50 Hz - 60 Hz
Rated current max. 7.6 The rated current in basic conguration values are pending conrmation.
Active power (min. conguration) 65 W
Active power (max. conguration) 432 W
Apparent power (max. conguration) 435 VA
Heat emission 1555.2 kJ/h (1474.0 BTU/h)
Compliance
Germany TÜV GS
Europe CE Class A *
USA/Canada CSAc/us
ULc/us
FCC Class A