6 - Conversion for LP or NG Gas
Proceed to Pressure Regulator Conversion
noting the LP / Propane position to comple-
te the conversion.
After replacing the injectors adjust the burner flame (see
Low Flame Adjustment paragraph).
Check the appearance of each burner’s flame at HILO
settings, if the flame appears too large or too small make
sure that all steps were completed correctly.
Converting Appliances for Use with NG
Gas
If this appliance should be converted for use with gas NG
(natural gas), each of the following modifications must be
performed.
1. Convert the pressure regulator to NG position as per the
section “Pressure Regulator Conversion”.
2. Replace all injectors following the step described on the
previous pages, observe the number stamped on the
side, this number corresponds to the orifice diameter
and its correct burner location (refer to the illustrations in
section: “Injectors Position”).
3. Adjust the burner flame (see Low Flame Adjustment
section).
Check the appearance of each burner’s flame at HI - LO
settings, if the flame appears too large or too small make
sure that all steps were completed correctly.
Pressure regulator conversion
The appliances is designed for use with NG gas or LP gas.
The gas pressure regulator is supplied. It must be installed in
the gas supply line ahead of the manifold entrance.
It is pre-set for use with the gas as indicated on the appliance
label supplied with the appliance. For use with different gas
the appliance must be converted.
For the pressure regulator conversion follow the instructions
below:
Disconnect all electrical power, at the main circuit breaker
or fuse box.
Shut off the gas supply to the cooktop by closing the
manual shut-off valve.
Adjust the pressure regulator, by following the instruction
(see figure)
1. Unscrew the regulator cap
2. Unscrew the plastic conversion plug from the cap turn
over and screw back (wide section away from cap for
LP and against cap for NG) see figures below.
3. Replace the regulator cap ensuring gasket is in place.
PRESSURE REGULATOR CONVERSION
NG
LP
NG POSITION
PLUG
PRESSURE REGULATOR
LP/PROPANE POSITION
GASKET
CAP
Before replacing the regulator cap, check if the position
of plug is suitable for the gas