Installation Instructions

EN
12
6 - Conversion for LP or NG Gas
Converting Appliance for Use with LP Gas
WARNING
Conversion is to be performed by an AUTHORIZED
SERVICER (or other qualified agency) in accordance with the
manufacturer’s instructions and all codes and requirements of
the authority having jurisdiction. Failure to follow instructions
could result in serious injury or property damage.
The qualified agency performing this work assumes
responsibility for this conversion.
WARNING
Electrical power and gas must be turned off prior to conversion.
If this appliance is to converted for use with gas LP (propane
or butane), each of the following modifications must be
performed:
Replace Injectors (two ring flame burner)
1. Remove the grates and burner caps.
2. Remove aluminium gas spreader.
3. Remove the three screws from the simmer gas spreader
(1).
4. Remove the two screws of the injector cover (2).
5. Remove injector (A) by using a 9-32” nut driver counter
clockwise.
6. Remove injector (B) by using a 9-32” box wrench counter
clockwise.
7. Install the injectors supplied with this appliance in the
appropriate burner. The injectors have small numbers
stamped on the side, this number corresponds with the
orifice diameter and its correct burner location (refer to
illustrations in the section: “Injectors Position”).
8. Turn clockwise to tighten (tighten to a torque of 15 to 20
inch-lbs).
9. Replace all parts following the reverse order.
10. Save the injectors removed from the appliances for
future use.
EXPLODED VIEW OF BURNER