Your range is equipped with a factory-connected
power cord. Cord must be connected to a grounded
120/240 volt or 120/208 volt range outlet. If no

electrician.
NEMA 10-50P PlugNEMA 14-50P Plug
NEMA 14-50R Receptacle NEMA 10-50R Receptacle
(for US only)
(for US only)

(for US only)
The user is responsible for connecting the power
supply cord to the connection block located behind
the back panel access cover.
This appliance may be connected by means
      
nonmetallic shielded copper cable), or by means of
a power supply cord kit. Use only a power supply
cord kit rated at 125/250 volts minimum and marked
for use with ranges. Cord must have either 3 or 4
conductors. Terminals on end of wires must either be
closed loop or open-end spade lugs with upturned
ends.
Use a power supply cord kit rated at minimum 50A
that is marked for use with nominal 1-3/8 in (34.93
mm) diameter connection openings.
1) Disconnect power.
2) Remove the terminal block cover screws located
on the back of the range.
3) Add strain relief if not provided.
NOTE: If necessary remove the knockout to
insert the strain relief.

Assemble a UL listed strain relief in the opening.
UL listed strain relief.
        
through the strain relief in the cord/conduit plate
on bottom of range. Allow enough slack to easily
attach the wiring to the terminal block.
Tighten strain relief screw against the power supply

Electrical connections