Dimensions
Weight & Dimensions
30” Gas Ranges Top 600 SERIES
PACKAGING 30”
lb /
inch
Kg /
mm
GROSS WEIGHT
99
lb 45 Kg
DIMENSION
W
D
H
38"3/4
32"1/8
32"1/8
984
817
340
PRODUCT DIMENSIONS
30” Wide Rangetop Models
29 3/4” (75,8)
29 1/2” (75,1)
30” (76,2)
min. 24” (61)
max. 25 5/8” (65)
2” (5)
7” (17,9)
2” (5)
2” (5)
7” (17,9)
10” (25,5)
16 3/8” (41,5)
2” (5)
27 3/8” (69,7)
27 3/8” (69,7)
29 3/4” (75,8)
7” (17,9)
CUTOUT REQUIREMENTS
The surface of the entire back wall above the range and below the hood must be covered with a noncombustible material.
*Consult local code for exact location requirements.
OPENING WIDTH A B
Rangetop 30” 30" (76.2) 24 1/4 (61.7)
Note: Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and not certied.
Clearances to non-combustible materials must
conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
Minimum clearances:
Above cooking surface (above 36” [91.4 cm])
• Sides - 6” (15.2 cm)
• Within 6” (15.2 cm) side clearance, wall cabinets no
deeper than 13” (33.0 cm) must be minimum 18” (45.7
cm) above cooking surface
• Wall cabinets directly above product must be a minimum
of 48”
(122 cm) above cooking surface.
• Rear - 0” with 9 ” backguard; 0” with non-combustible
rear wall.
Below cooking surface (36” [91.4 cm] and below)
Install with zero clearance between adjacent combustible
construction below the cooking surface and the back
and sides of the appliance.
ADDITIONAL CLEARANCES:
For island installation, maintain 2-½ in. minimum from
cutout to back edge of countertop and 3 in. minimum from
cutout to side edges of countertop (see top view).
For island installation, 12” (30.5 cm) minimum clearance
back of rangetop to combustible rear wall above countertop.
The island installation is
no
t part of the ANSI Z21.1 scope
and not certifi ed.
FLUSH ISLAND INSTALLATION
BACK
min 3” (7.6) min 3” (7.6)
min 2 1/2” (6.3)
13"3/8
min 18” (45,7)
max 13” (33)
A
min 6” (15,2) min 6” (15,2)
min 30” (76,2)
to bottom of
ventilation hood
min 48” (122)
Minimum to
Combustibles
Electrical and Gas
connections
in this area