Installation Instructions

EN
4
2 - Product Dimensions and Cutout Requirements
CUTOUT REQUIREMENTS
ELECTRICGAS
B B
*Suggested location
of utilities
2” (5.1) max. protusion from
wall for gas or electrical supply
3” (7.6)
4” 3/4 (12.3)
A
Min. 18” (45.7)
Min. 30” (76.2)
To bottom of
ventilation hood
Min. 18” (45.7)
Max. 13” (33)
Min. 6”
(15.2)
Min. 6”
(15.2)
C
The surface of the entire back wall above the range and below the hood must be covered with a noncombustible material.
*Consult local code for exact location requirements.
OPENING WIDTH A & C B
Range 30” 30" (76.2) 6” (15.2)
Range 36” 36" (91.4) 7” (17.8)
Note: Clearances to non-combustible materials must
conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
Minimum clearances:
Above cooking surface (above 36” [91.4 cm])
Sides 3” (7.6 cm)
Within 3” (7.6 cm) side clearance, wall cabinets no
deeper than 13” (33.0 cm) must be minimum 18” (45.7
cm) above cooking surface.
Wall cabinets directly above product must be a minimum
of 30” (76.2 cm) above cooking surface.
Rear - 0” with 3” (7.6 cm) backguard.
ADDITIONAL CLEARANCES:
For island installation, maintain 2-½ in. minimum from
cutout to back edge of countertop and 3 in. minimum from
cutout to side edges of countertop (see top view).
FLUSH ISLAND TRIM INSTALLATION
BACK
min 3” (7.6) min 3” (7.6)
min 2 1/2” (6.3)