UsingtheproperchargeriscriticaltotheperformanceandlifeofyourAGM
orGelbattery.IfyouarenotsureifyouhavetherightchargerforAGMorGel
batteries, please call our technical support line at (800) 522-8191 or email help@
fullriverbattery.comforverication.
4.1 - CHARGER INSPECTION
1. Thechargercableshouldbeinsulatedandfreeofbreaksorcuts.
2. Thecableconnectorsshouldbecleanandproperlymatedwiththebattery
terminals to ensure a snug connection.
3. Thecharger’sACcordshouldbefreeofbreaksorcutsandthewallplug
shouldbeclean.
4.2 - CHARGING YOUR BATTERIES
1. UseanAGMchargerorsettingwheneveravailableforAGMbatteries.Usea
GelchargerorsettingwheneveravailableforGelbatteries.
2. NeveruseaGELchargerorsettingonanAGMbattery,asitwillundercharge
thebatteryandsignicantlyreducebatterycapacityandlife.
3. Many,butnotall,wetbatterychargerswillworkforanAGMbattery.Call
technical support at (800) 522-8191 or email help@fullriverbattery.com
toverifyyourcharger.Bepreparedtoprovidethemakeandmodelofyour
charger.
4. Batteriesshouldbefullychargedaftereachuse.Opportunitychargingcanbe
done,butthebatteriesshouldbefullychargedatleasteveryotherdayifthey
areuseddaily.
5. Chargeinaventilatedarea,asgasesmaybereleasedthroughthepressure
reliefvalveifthebatteriesareexcessivelyover-charged.
6. Ifthechargerdoesnothavetemperaturecompensation,avoidchargingat
temperatures above 122°F (50°C).
4.3 - CHARGING TEMPERATURE RANGE
4.4 - CHARGING PARAMETERS
Mostchargerscomepre-setfromthefactory.Ifyourchargerispre-programmed,
usetheinformationbelowtocheckifthesettingsarecompatiblewithAGMor
Gelbatteries.Ifyouhaveaprogrammablechargerorinverter,usethefollowing
information for settings.
Charging
Yes
No
5°F to 122°F (-15°C to 50°C)
32°F to 104°F (0°C to 40°C)
Temp Compensation
Recommended
TABLE 5
-40°F to 160°F (-40°C to 71°C)
5°F to 122°F (-15°C to 50°C)
Maximum