AGM Sealed 6V 415Ah Manual
www.FullriverbaTTery.com Page 15
3. Ifthesetrunsmorethan60%ofitsratedcapacity,thebatteriesaregoodand
the test is complete.
4. Ifthesetrunslessthan60%ofitsratedcapacity,reconnectthedischarger.
Whileunderthedischargeload,recordtheendofthedischargevoltagefor
each battery.
5. Thebatteriesthatare0.5Vlowerthanthehighestendofdischargevoltage
shouldbenoted.
6. Ifthesetdeliveredlessthan60%ofitsratedcapacity,andthesamebatteries
thatwerenotedinSTEP 3 of SECTION 6.2werealsotheonesnotedinSTEP 5
of SECTION 6.3,thosebatteriesaremostlikelyfailedandshouldbereplaced.
Follow the replacement instructions in SECTION 6.6 below.
7. Otherwise,pleasecontactyourlocalFullriverBatterydistributortoreview
yourdataindetail.Youcanalsoreachtechnicalsupportbycalling
(800) 522-8191 or emailing help@fullriverbattery.com.Additionaltesting
mayberequireddependingonyourspecicapplication.
6.4 - OPTIONAL TEST
After completing SECTION 6.1andSECTION 6.2, follow these steps:
1. Operatethevehicle/equipmentuntilbatteryperformancedecreases.
2. Recordvoltagesduringandafteroperation.
3. Recordtimeanddistanceofoperation.
4. Providethevoltage,time,anddistancedatatoaFullriverBatterydistributor
or to Fullriver Battery technical support at (800) 522-8191 or email
help@fullriverbattery.com.
5. Thisdatawillbeanalyzedincomparisontowhatisexpectedofthe
vehicle/equipment.
6.5 - CCA TEST (only applicable to Full Throttle series batteries)
1. ConnectandstartcarbonpileloadtesteraccordingtoCCAratinglistedon
battery.
2. Recordalldataduringtest(startvoltage,endvoltage,pass/fail,testermodel,
etc.).
3. Providethevoltage,time,andtesterdatatoaFullriverBatterydistributoror
to Fullriver Battery technical support at (800) 522-8191 or email
help@fullriverbattery.com.
Testing