Installation Guide
(800) 522-8191 toll freePage 10
UsingtheproperchargeriscriticaltotheperformanceandlifeofyourAGMbattery.
IfyouarenotsureifyouhavetherightchargerforAGMbatteries,pleasecallour
technical support line at (800) 522-8191 or email help@fullriverbattery.com for
verication.
4.1 - CHARGER INSPECTION
1. Thechargercableshouldbeinsulatedandfreeofbreaksorcuts.
2. Thecableconnectorsshouldbecleanandproperlymatedwiththebattery
terminals to ensure a snug connection.
3. Thecharger’sACcordshouldbefreeofbreaksorcutsandthewallplug
shouldbeclean.
4.2 - CHARGING YOUR BATTERIES
1. UseanAGMchargerorsettingwheneveravailable.
2. NeveruseaGELchargerorsettingonanAGMbattery,asitwillundercharge
thebatteryandsignicantlyreducebatterycapacityandlife.
3. Many,butnotall,wetbatterychargerswillworkforanAGMbattery.Call
technical support at (800) 522-8191 or email help@fullriverbattery.com
toverifyyourcharger.Bepreparedtoprovidethemakeandmodelofyour
charger.
4. Batteriesshouldbefullychargedaftereachuse.Opportunitychargingcanbe
done,butthebatteriesshouldbefullychargedatleasteveryotherdayifthey
areuseddaily.
5. Chargeinaventilatedarea,asgassesmaybereleasedthroughthepressure
reliefvalveifthebatteriesareexcessivelyover-charged.
6. Ifthechargerdoesnothaveatemperaturecompensation,abovechargingat
temperatures above 122°F (50°C).
4.3 - CHARGING TEMPERATURE RANGE
Charging
Yes
No
5°F to 122°F (-15°C to 50°C)
32°F to 104°F (0°C to 40°C)
Temp Compensation
Recommended
TABLE 5
-40°F to 160°F (-40°C to 71°C)
5°F to 122°F (-15°C to 50°C)
Maximum