TABLE 6  RECOMMENDED GASKET LOADS FOR FLEXITALLIC SPIRAL WOUND CLASS 150#
GASKETS SAE GRADE 5 BOLTS OR EQUAL
Nominal Flange Size
(inches)
Number of Bolts Diameter of Bolts
(inches)
Preferred Torque Req.
Per Bolt (ft-lb)
1/2 4 1/2 45
3/4 4 1/2 45
1 4 1/2 45
1 1/4 4 1/2 45
1 1/2 4 1/2 45
2 4 5/8 90
2 1/2 4 5/8 90
3 4 5/8 90
3 1/2 8 5/8 90
4 8 5/8 90
5 8 3/4 150
6 8 3/4 150
8 8 3/4 150
10 12 7/8 240
TABLE 7  RECOMMENDED LOADS FOR FLEXITALLIC SPIRAL WOUND CLASS 300# GASKETS
SAE GRADE 5 BOLTS OR EQUAL
Nominal Flange Size
(inches)
Number of Bolts Diameter of Bolts
(inches)
Preferred Torque Req.
Per Bolt (ft-lb)
1/2 4 1/2 45
3/4 4 5/8 90
1 4 5/8 90
1 1/4 4 5/8 90
1 1/2 4 3/4 150
2 8 5/8 90
2 1/2 8 3/4 150
3 8 3/4 150
3 1/2 8 3/4 150
4 8 3/4 150
5 8 3/4 150
6 12 3/4 150
8 12 7/8 240
10 16 1 368