TABLE 8 RECOMMENDED LOADS FOR JM CLIPPER ELASTOGRAPH 150# GASKETS SAE
GRADE 5 BOLTS OR EQUAL
Nominal Flange Size
(inches)
Number of Bolts Diameter of Bolts
(inches)
Preferred Torque Req.
Per Bolt (ft-lb)
1/2 4 1/2 30
3/4 4 1/2 30
1 4 1/2 30
1 1/4 4 1/2 30
1 1/2 4 1/2 30
2 4 5/8 60
2 1/2 4 5/8 60
3 4 5/8 60
4 8 5/8 60
5 8 3/4 100
6 8 3/4 100
8 8 3/4 100
10 12 7/8 160
TABLE 9 RECOMMENDED LOADS FOR JM CLIPPER ELASTOGRAPH 300# GASKETS SAE
GRADE 5 BOLTS OR EQUAL
Nominal Flange Size
(inches)
Number of Bolts Diameter of Bolts
(inches)
Preferred Torque Req.
Per Bolt (ft-lb)
1/2 4 1/2 30
3/4 4 5/8 60
1 4 5/8 60
1 1/4 4 5/8 60
1 1/2 4 3/4 100
2 8 5/8 60
2 1/2 8 3/4 100
3 8 3/4 100
4 8 3/4 100
5 8 3/4 100
6 12 3/4 160
8 12 7/8 245
10 16 1 160