Symptom Remedy
The unit does not work, no light Check the mains connection and the main fuse.
No response to the DMX con‐
troller
1. When the display ashes, e.g. ‘d001’ , no valid DMX
signal is received. Check whether the DMX controller is
switched on. Check the DMX connectors and cables for
proper connection.
2. If the display is not ashing but there is still no
response, check the address settings and the DMX
polarity.
3. Try using another DMX controller.
4. Check whether the DMX cables run near or parallel to
high-voltage cables that may cause damage or interfer‐
ence to a DMX interface circuit.
If the procedures recommended above do not succeed, please contact our Service Center. You
can nd the contact information at www.thomann.de.