Product Overview

010816
(800) 888-5538 sales@functionaldevices.com www.functionaldevices.com
CURRENT
SENSORS
Wire Being
Monitored
Removable Mounting Tab
2.520”
1.100”
1.750”
2.000”
2.000”
Wire Clamp
Threshold Adjust
LED 2
LED 1
(if present)
.52” x .52” – Opening for
Wire Being Monitored
Sensor
Contact
Wire Being Monitored
Wht/Yel
Wht/Yel
RIBXGA
RIBXGTF
-SCAL LED TABLE
LED O No Current
Two Winks Current Below Range
Three Winks Current In Range
Four Winks Current Above Range
Continuous Winks Calibration in Progress
The SCAL unit begins the 30 second self-calibration process the rst time current is applied in the operating range. The
threshold is then set. Subsequent calibrations may be performed by moving SW1 to the position opposite of its current
position with or without current applied (hands can be safely away from live voltage). Once current begins owing, or if it
already is, the calibration process will begin. At the end of the 30 seconds, amperage will be read and set as the threshold.
SW2 in the ON position provides a 15% (+/-3%) dierential. In the OFF position, it provides a 25% (+/-3%) dierential. SW2
can be selected at anytime and does not aect the threshold setting. Current in-range closes the sensor contact. Current
above or below range opens the sensor contact.
Example: With a current of 10 amps set as the threshold and a 15% dierential, sensor contact will be closed between 8.5
amps and 11.5 amps and open outside of this range. A small amount of hysteresis is provided to prevent dithering near the
dierential limits.
DIP Switch
LED 1
Sensor
Contact
SELFCALIBRATING AC SWITCHES (Models with -SCAL Sux)
RIBXGTA-SCAL
RIBXGA-SCAL
Operating Temperature:
Humidity Range:
Max Sense Voltage:
Approvals:
Mounting/Installation:
Sensor Contact Status:
-30 to 140° F
5 to 95% (noncondensing)
600 Vac
UL Listed, UL916, UL864, C-UL,
California State Fire Marshal, CE, RoHS
Removable mounting tab provided. The
wire clamp locks against the wire being
monitored, securing the unit in place.
Current below threshold: Open
Current above threshold: Closed
RIBXG Series
Enclosed Self-Powered Split Core AC Sensors
Made in USA
Meets
Buy American
of ARRA 2009
* = Not approved by California State Fire Marshal
Sensor Contact:
Solid State Contact
When sensor contact is o (open), leakage
<30 uA @ 30Vac/dc
When sensor contact is on (closed), voltage drop
< .3 Vac/dc @ .1 Amp
< 1.6 Vac/dc @ .4 Amp
Made in USA
Meets
Buy American
of ARRA 2009
RIBXG SERIES SELECTION GUIDE
Model#
Sensing
Range
Type Threshold
Sensor Contact
Type
Switching
Voltage
Range
Maximum
Switching
Current
Sensor Contact
Termination
LED 1 LED 2
RIBXGF .35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16˝ 18 AWG Wire Leads
RIBXGFL* .75-150 Amp Split Core Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16˝ 18 AWG Wire Leads Over Trip Point
RIBXGTF .35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire
RIBXGTFL* .75-150 Amp Split Core Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point
RIBXGA .75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16˝ 18 AWG Wire Leads Over Trip Point Under Trip Point
RIBXGTA .75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Under Trip Point
RIBXGA-SCAL 3-150 Amp Split Core Self-Cal. Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16˝ 18 AWG Wire Leads See -SCAL Table
RIBXGTA-SCAL 3-150 Amp Split Core Self-Cal. Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire See -SCAL Table
AC CURRENT SWITCHES
SPECIFICATIONS
FUNCTIONAL DEVICES CERTIFIED FOR USE WITH ECMS