Owner's Manual
Table Of Contents
11
Specifications
AC Current Capacity
Input: 15 Amp capacity required (10 Amp for the AC-210 E)
Output: 15 Amp RMS (both outlets combined) (10 Amp for the AC-210 E)
AC Noise Attenuation, Transverse (Differential) Mode
>40dB from 10kHz to 100kHz
>80dB from 100kHz to 1GHz
(linear attenuation curve from 0.05 to 100Ω line impedance)
Transient Voltage Surge Suppression
120VAC (230VAC for AC-210 E)
Series Multi-Stage Protection Plus Non-Sacrificial with Zero Ground contamination
Domestic (AC-215): 188V peak clamping @ 6000V/3000A input
International (AC-210 E): 276V peak clamping for AC-210 E
Extreme Voltage Shutdown
137 VAC typically (AC-215)
275 VAC typically (AC-210 E)
Dimensions & Weight
1.75” (H) x 5” (W) x 8.5” (D), 3 lbs.
Safety Agency Listing
CE / TUV / NRTL-C
MADE IN CHINA