Specifications
AC Current Capacity
Input - 15 Amp capacity required
Output - 11 - 15 Amp RMS * (maximum, all outlets combined - continuous)
* (Due to the Power Factor Technology circuit, available RMS power varies with the reactance of the load (vector).
However, this only aects the circuit breaker for continuous RMS current draw. Since power ampliers will require high
transient current demands, the IT-Reference 15i will never succumb to current compression. Quite the opposite, in fact,
it will buer the power amplier’s power supply, while lowering the AC input impedance, allowing power ampliers to
work more eciently.
Linear Noise Attenuation
Transverse (Dierential) Mode
>40 dB from 4Khz. - 100 kHz.
>80 dB from 100 kHz. – 1GHz.
(Linear attenuation curve from 0.05 – 100 ohms line impedance)
Common Mode
>90 dB from 10Hz. - 50 kHz.
>40 dB from 50kHz. – 1MHz.
Outlets:
2 (discrete symmetrical outlets)
5 (linearly ltered outlets)
4 (Power Factor Technology outlets – 4.5 amps RMS reserve – resistive load – over 55 amps pk. charge)
Transient Voltage Surge Suppression
120VAC Line
Series Multi-Stage Protection - Non-Sacricial with zero ground contamination
188V peak clamping @ 6000V 3000A input
Telco Cable / Satellite
Less than .1dB line loss
Shutdown Range
140 VAC +/- 3 VAC
Dimensions:
4” H x 17” W x 15.625” D (standard 2RU without feet)
Weight:
50 lbs.
Power Consumption:
8.5 Watts for display and control circuits independent of actual load
Safety Agency Listing: